The primary objective of this investigation is to assess the effectiveness of transcutaneous electrical nerve stimulation applied using VECTTOR to reduce the symptoms of Duchenne Muscular Dystrophy and reduce the impact of DMD upon the participants' quality of life.

The primary outcome measures will include:

1. increased muscle strength, 2. increased range of joint motions and 3. improved sleep parameters of ASI, N3 and REM.

Completed

Looking for future studies?

Notify Me

Key information

About this study

Muscle Strength and Joint Range of Motion Testing - All muscle and joint testing was performed at the MedCenter Therapy clinic in Houston, Texas. JTech computerized testing system was utilized including Goniometry, Grip testing, Inclinometry, Muscle Testing and Joint Range of Motion testing occurred on Day 0, 30, 60, 90, 180, and repeated at 12 months to determine muscular strength and joint Range of Motion. JTech computerized testing system was chosen on the basis of reliability and accuracy. At each of the testing intervals, the testing was administered by the same technician with the same equipment to all of the participants. Inter-and intra-tester reliability of the JTech computerized testing system has been the subject of multiple studies. Each of which found high ICCs (>0.93) for both inter- and intra-tester reliability.

All sleep studies were performed at Sleep Diagnostics of Texas in The Woodlands, Texas. Prior to the clinical trial, all of the participants spent two nights in the sleep unit and their sleep study examinations were performed. The second night was used as the Day 0 data. Sleep, breathing, arousals and limb movements were scored manually according to guidelines set forth by the American Academy of Sleep Medicine. The sleep studies were repeated at 6 months and 1 year.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Participants must have Duchenne Muscular Dystrophy diagnosis as confirmed by licensed physician, wheelchair bound, & age 8 - 20 years old.

Exclusion criteria

  • Active cancer in the area of application of the treatment, infection, skin infection, pregnancy, thrombophlebitis, pacemaker, amputation of any part of feet or hands, taking steroids. In addition, the participant may not be in any other clinical trial during the time they are in this study.

Treatment and study plan

VECTTOR

Device

The VT-200, or VECTTOR system, delivers electrical stimulation via electrodes on the acupuncture points of a patient's feet/legs and hands/arms to provide symptomatic relief of chronic intractable pain and/or management of post-surgical pain.

Once these electrodes are placed, the machine determines the appropriate choice of stimulation by automatically measuring body temperatures through the use of thermistors placed on the fingers during a testing sequence.

Other names: electrical nerve stimulator

Primary outcomes

  1. Percent Change in Range of Motion From Baseline to 180 Days

    Time frame: Baseline to 180 days

    Range of Motion (ROM) testing (Wireless Tracker System) - All muscle and joint testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90 and 180 days to determine changes in joint Range of Motion. JTech computerized testing system determined the joint range of motion by radio signals from a goniometer measuring movement of the participants' joints. 44 separate tests were performed for Range of Motion for each participant at each time interval. The results from the range of motion tests were averaged the percent change from baseline to 180 days. Efficacy is defined as an increase in range of motion.

Secondary outcomes

  1. Percent Change in Muscle Strength

    Time frame: Baseline to 180 days

    Muscle strength testing (Wireless Tracker system) - All muscle strength testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90, and 180 days to determine changes in muscle strength. JTech computerized testing system determined the muscle strength by radio signals from a strain gauge measuring strength of the participant's muscles. 44 separate tests were performed for muscle strength for each participant at each time interval. Efficacy is defined as an increase in the strength measurement (pounds) from Baseline to 180 days.

  2. Percent Change in Percent Range of Motion From Baseline to 365 Days

    Time frame: Baseline to 365 days

    Range of Motion (ROM) testing (Wireless Tracker System) - All muscle and joint testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90, 180 and 365 days to determine changes in joint Range of Motion. JTech computerized testing system determined the joint range of motion by radio signals from a goniometer measuring movement of the participants' joints. 44 separate tests were performed for Range of Motion for each participant at each time interval. The results from the range of motion tests were averaged the percent change from baseline to 365 days. Efficacy is defined as an increase in range of motion.

  3. Percent Change in Muscle Strength

    Time frame: Baseline to 365 days

    Muscle strength testing (Wireless Tracker system) - All muscle strength testing was performed using the JTech computerized testing system, including Goniometry, Grip Testing, Inclinometry, Muscle Testing and Joint Range of Motion. Testing occurred at Baseline (Day 0), 30, 60, 90, 180 and 365 days to determine changes in muscle strength. JTech computerized testing system determined the muscle strength by radio signals from a strain gauge measuring strength of the participant's muscles. 44 separate tests were performed for muscle strength for each participant at each time interval. Efficacy is defined as an increase in the strength measurement (pounds) from Baseline to 365 days.

Other outcomes

  1. Percent Change in Sleep Quality Arousal Statistics Index (ASI) From Baseline to 180 Days

    Time frame: Baseline to 180 days

    Sleep / Arousal Statistics Index (ASI) description: Sleep Studies were obtained twice before beginning the study. The second sleep study data was used as baseline. A follow up sleep study was obtained after 6 months (180 days) of Active or Placebo VECTTOR treatment. Sleep, breathing, arousal(s), and limb movements were scored manually according to guidelines of the American Academy of Sleep Medicine. The efficacy of the outcome measure of ASI is demonstrated by a percent improvement between Baseline and 180 days. The ASI is measured by the number of times sleep is interrupted per hour.

  2. Sleep Arousal Statistics Index at 365 Days

    Time frame: Baseline to 365 days

    Sleep / Arousal Statistics Index (ASI) description: Sleep Studies were obtained twice before beginning the study. The second sleep study data was used as baseline. A follow up sleep study was obtained after 6 months (180 days) of Active or Placebo VECTTOR treatment. Sleep, breathing, arousal(s), and limb movements were scored manually according to guidelines of the American Academy of Sleep Medicine. The efficacy of the outcome measure of ASI is demonstrated by a decrease in the value between Baseline and 180 days. The ASI is measured by the number of times sleep is interrupted per hour. Lower ASI values/numbers indicate improved sleep quality.

Sponsors and collaborators

Lead sponsor

Alan Neuromedical Technologies, LLC

Industry

Registry information

Official study title

Double-blind, Randomized, Placebo-controlled Study of VECTTOR Treatment for Duchenne Muscular Dystrophy

Acronym: DMD

Important dates

Study start
2013
Primary completion
2014
Study completion
2014
First posted
Jun 11, 2013
Registry last updated
May 4, 2015

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.