E-poly
Othercomparison of two different polyethylene plastic 0,04 mm at 3 months 0,06 at 2 years
NCT Number: NCT02801019
Vitamin E incorporated highly cross linked polyethylene (E-XLPE) was developed to increase oxidative resistance of highly cross-linked polyethylene (XLPE) without affecting mechanical properties. The investigators evaluated this type of polyethylene in a randomized clinical study, using Radiostereometric Analysis (RSA). The objective of this study was to compare the early-term wear of E-XLPE to a compression annealed polyethylene liner (C-XLPE, ArComXL®). The clinical outcome at two years was not expected to be affected by the choice of polyethylene.
Looking for future studies?
Notify Me20 year–75 year
All sexes
Interventional
Not applicable
First generation of modern highly cross-linked polyethylene (XLPE) was clinically introduced in 1998 and has in most countries become standard as bearing surface in total hip arthroplasty. Studies of these materials have shown significantly reduced femoral head penetration when compared to gamma sterilized conventional polyethylene.
Thermaly treating (melting or annealing) is often a part of the manufacturing process of highly cross-linked polyethylenes. The polyethylene is exposed to irradiation to achieve cross-linking and improve wear resistance. Cross-linking by irradiation increases the amount of free radicals in the material.These radicals must be eliminated or stabilized to avoid oxidative degradation over time.Thermal treatment improves oxidation resistance but potentially changes the mechanical properties of the polyethylene.
By annealing i.e. heat treatment under the melt temperature the material maintains better mechanical properties, but elimination of free radicals is suboptimal, which can lead to oxidation in vivo.Heat treatment of the polyethylene above the melt temperature will more effectively reduce or eliminate the amount of residual free radicals. This will increase oxidation resistance, but will negatively influence the mechanical properties of the material.
Due to these limitations new generations of cross-linked polyethylene materials have been developed. Introducing Vitamin E (α-tocopherol), a natural antioxidant into the material prevents oxidative degradation and stabilizes the free radicals found in irradiated polyethylene plastic. In laboratory tests, polyethylene liners with incorporated vitamin-E have demonstrated similar wear, greater strength and better resistance to oxidation compared with the first generation cross-linked polyethylene. Currently, there are only laboratory studies on vitamin E diffused polyethylene available.
The hypothesis in this study is that the early-term E-XLPE wear is low and comparable to a heat-treated XLPE. The investigators also hypothesize that implant fixation and clinical outcome at two years will be unaffected by the choice of polyethylene.
The investigators therefore evaluated the early bedding in and wear in an uncemented arthroplasty supplied with liners made of vitamin E diffusion doped XLPE (E1®, Biomet, Warsaw, IN, USA). In the control group the investigators used the same uncemented hip prosthesis with polyethylene liners manufactured to achieve high levels of crosslinking without sacrificing the mechanical strength and extinguish residual free radicals (ArComXL® , Biomet, Warzaw, IN, USA).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
comparison of two different polyethylene plastic 0,04 mm at 3 months 0,06 at 2 years
comparison of two different polyethylene plastic 0,03 mm at 3 months 0,10 mm at 2 years
Time frame: up to 2 years
Evaluation of the early bedding in and wear in an uncemented arthroplasty supplied with liners made of vitamin E diffusion doped XLPE in comparsion to annealed polyethylene liner, ArComXL.
Time frame: up to 2 years
Evaluation of cup and stem translations of vitamin E incorporated highly cross linked polyethylene compared to annealed polyethylene liner ArComXL liner.
Time frame: Postoperatively, whitin 3 to 5 days after surgery
The differences between the postoperative double-examinations was used to compute the precision for the method.
Sahlgrenska University Hospital
Other
Wear and Creep of Vitamin E-Diffused Highly Cross-Linked Polyethylene Liners Randomized Radiostereometric Study of 70 Hips Followed for 2 Years
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02108496
Arthritis, Joint Diseases
Indianapolis, Indiana, United States
View Trial DetailsNCT07720024
Arthritis, Blount disease
Pathum Thani, Changwat Pathum Thani, Thailand
View Trial DetailsNCT01818401
Arthritis, Joint Diseases
Nantes, France
View Trial DetailsNCT07710404
Arthritis, Joint Diseases
Faisalābad, Punjab Province, Pakistan
View Trial Details