This study sets out to evaluate the EpiMaster application software for use in predicting the refractive change induced by a trans-epithelial phototherapeutic keratectomy (TE-PTK) procedure in eyes with irregularly irregular astigmatism. If validation criteria are met during the observational phase, the software refractive prediction will be used to plan the refractive correction in TE-PTK treatments.
This study is active but is not currently recruiting participants.
Notify Me21 year–70 year
All sexes
Interventional
Not applicable
London, W1G 7LA, United Kingdom
Complications after laser eye surgery can often result in the front surface of the eye (the cornea) becoming irregular, which causes visual symptoms such as halos, glare, starbursts, double vision, and reduced contrast sensitivity. For the past 20 years, corneal irregularities have been treated using wavefront-guided ablation, topography-guided ablation or trans-epithelial phototherapeutic keratectomy (TE-PTK). Topography-guided ablation is the most effective treatment for certain types of irregularity and works by using a laser to remove tissue from the cornea in a pattern derived from a topography scan (a measurement of the shape and curvature of the front of the eye) designed to make the corneal surface more regular.
However, topography-guided ablation is less effective for other types of irregularity. In these cases, the corneal epithelium (the layer of skin on the surface of the cornea) has changed in thickness to partially hide the irregularity on the body of the cornea under the epithelium (the stroma). The epithelium does this by becoming thinner over peaks and thickening over troughs in the stroma. Therefore, the topography measurement can only detect the proportion of the irregularity that has not been hidden by the epithelium, hence reducing its effectiveness. The preferred treatment option is TE-PTK; the laser treatment is applied onto and through the epithelium, breaking through to the stroma where the epithelium is thinnest, thus removing tissue from the peaks on the stroma resulting in a more regular surface.
The main weakness of TE-PTK is that it may unpredictably change the refraction to become more short-sighted or more long-sighted or change the astigmatism. To improve this, we have developed the Epimaster software that simulates a TE-PTK treatment and predicts the change in refraction.
The aim of the study is to validate the refractive prediction produced by the Epimaster software by comparing this to the achieved result in the patients treated. The treatment received by the patient will be the same as has been used routinely for the past 20 years.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Medically suitable for corneal laser refractive surgery.
Exclusion criteria
The MEL 90 excimer laser will be used to ablate the corneal epithelium and stroma to a pre-defined depth, using the epithelium as a natural masking agent to smooth the stromal surface.
The MEL 90 excimer laser will be used to ablate the corneal epithelium and stroma to a pre-defined depth, using the epithelium as a natural masking agent to smooth the stromal surface.
The EpiMaster Application Software imports epithelial thickness data and corneal front surface topography data, and uses this to calculate the refractive change that would be induced by a trans-epithelial PTK treatment.
Time frame: 3-12 months
The correct tendency of manifest sphere, cylinder and axis should be achieved in 90% of cases, where tendency refers to:
Time frame: 12 months
Standard deviation of SEpostop-SEpredicted at each follow-up time point (represents the scatter of the refractive outcome), where SEpredicted is the refractive outcome predicted by the EpiMaster application software.
London Vision Clinic
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06285695
Aphakia, Astigmatism
Calgary, Alberta, Canada
View Trial DetailsNCT05985304
Astigmatism, Cataract
Fayetteville, Arkansas, United States
View Trial DetailsNCT07198126
Astigmatism, Conjunctival Diseases
Lahore, Punjab Province, Pakistan
View Trial DetailsNCT07081919
Astigmatism, Cataract
Shanghai, Shanghai Municipality, China
View Trial Details