University of Alabama at Birmingham
Birmingham, Alabama, 35294-0007, United States
NCT Number: NCT03468998
This study will evaluate the effect of allograft bone particle size on the bone quantity and quality following socket grafting and lateral ridge augmentation in preparation for endosseous implant placement.
Pre (baseline)- and post-grafting (3 months for sockets and 6 months for edentulous ridges) clinical as well as 2- and 3-dimensional radiographic measurements will be used to evaluate the differences between sites grafted with small vs. large particle sized bone allografts.
Histological analysis will be performed at time of surgical re-entry of grafted sites to place the dental implants, and assessed for differences in new bone formation between the 2 types of grafts.
Looking for future studies?
Notify Me18 year–99 year
All sexes
Interventional
Not applicable
Birmingham, Alabama, 35294-0007, United States
This study is a prospective, two-arm, randomized trial that will evaluate and compare the bone healing following ridge preservation of extraction sockets (RP, Arms 1 and 2) or lateral ridge augmentation of edentulous sites (RA, Arms 3 and 4) using either small particle (SP) or large particle (LP) mineralized cortico-cancellous bone allografts in a total of 48 patients (12 in each arm).
Study approval was obtained from the university's institutional review board. Qualifying participants and defects are randomized following a computerized permutation block to receive either LP or SP allografts on day of surgery. In the RP arms, tooth extraction is performed with a flapless minimally invasive technique, followed by socket grafting with a randomized graft covered with a collagen dressing and sutures. In the RA arms, lateral ridge augmentation is conducted utilizing a randomized bone graft covered by a collagen membrane fixated with tacks.
The mineralized cortico-cancellous bone allografts utilized in this study were all obtained from the same donor, lot and tissue bank to account for variation in age, race, gender and related healing potential of different graft sources.
In the RP arm, bone core biopsies will be harvested at time of implant placement 3 months following socket grafting, whereas similar biopsies will be obtained at 6 months following lateral ridge augmentation in the RA group. These 2x2x6 mm bone cores will then undergo histological and histomorphometrical analyses to determine qualitative and quantitative healing differences between LP and SP in all study arms.
Clinical measurements are gathered at 2 time points (grating and implant placement) at all defects and will be compared for differences.
Cone beam computed tomography (CBCT) initial scans are conducted immediately following socket grafting (RP arms) and prior to ridge augmentation (RA arms) and second scans obtained prior to implant placement (all RP and RA arms). Virtual implant planning software (coDiagnostiX) will be utilized to assess and compare the 2- and 3-dimensional changes for all defects.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Small Particle Bone Allograft of 0.25-1.0 mm placed in extraction socket
Large Particle Bone Allograft of 1.0-2.0 mm placed in extraction socket
Small Particle Bone Allograft of 0.25-1.0 mm used in lateral ridge augmentation (Guided Bone Regeneration) and covered with a collagen membrane
Large Particle Bone Allograft of 1.0-2.0 mm used in lateral ridge augmentation (Guided Bone Regeneration) and covered with a collagen membrane
Time frame: 3 months following socket preservation and 6 months following ridge augmentation
Compare histomorphometric amount of new bone formation (in %) between small and large particle bone allografts following ridge preservation and ridge augmentation procedures using core biopsies harvested at time of dental implant placement.
Time frame: from time of grafting until implant placement (3 months following ridge preservation and 6 months following ridge augmentation)
Using cone beam computed tomography and implant planning software, the bucco-lingual ridge width is measured (in mm) relative to a fixed digital reference and compared between the 2 bone particle groups
University of Alabama at Birmingham
Other
A Randomized Trial to Evaluate the Effect of Allograft Bone Particle Size on Histomorphometric and Clinical Outcomes Following Ridge Preservation/Augmentation Procedures
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06265467
Alveolar Ridge Augmentation, Maxillary Sinus
Ismailia, Egypt
View Trial DetailsNCT06206577
Alveolar Ridge Augmentation
Al Mansurah, Egypt
View Trial DetailsNCT06200077
Alveolar Ridge Augmentation
Al Mansurah, Dakahlyia, Egypt
View Trial DetailsNCT06177899
Alveolar Bone Loss, Alveolar Ridge Augmentation
Istanbul, Turkey (Türkiye)
View Trial Details