Cera™ patent foramen ovale occluders
DevicePatients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with the Cera™ patent foramen ovale occluders according to the INSTRUCTIONS for Use (IFU).
NCT Number: NCT05774288
To evaluate the performance of Cera™ patent foramen ovale occluders developed by Lifetech Scientific (Shenzhen) Co., LTD;
Interested in participating?
Request Info18 year–60 year
All sexes
Interventional
Not applicable
Fuwai Hospital ,CAMS&PUMC, Beijing, Beijing Municipality, China
The purpose of this prospective, multi-center, randomized, controlled non-inferiority clinical trial was to evaluate the safety and efficacy of Cera™ patent foramen ovale occluders developed by Lifetech Scientific (Shenzhen) Co., LTD for the treatment of cryptogenic stroke complicated with patent foramen ovale. The study required the implant to follow instructions strictly.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with the Cera™ patent foramen ovale occluders according to the INSTRUCTIONS for Use (IFU).
Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with the Another patent foramen ovale occluders according to the INSTRUCTIONS for Use (IFU).
Time frame: 180 days after surgery
Effective occlusion was defined as: 180 days after the surgery, Transthoracic echocardiography (TTE) showed that the position and shape of the occluder were normal, and no horizontal atrial shunt was observed. Re-examination by Contrast transthoracic echocardiography (cTTE) showed no or only a small amount of right-to-left shunt, that is, no microvesicles or less than 10 microvesicles/frame in left heart cavity after Valsalva and resting state.
Time frame: 7 days after surgery
The success of occluder implantation technology is defined as successful intraoperative implantation of occluder and immediate Echocardiography confirmed that the shape and position of the sealing device were appropriate, no new pericardial effusion or valve regurgitation was found, and the perioperative patients survived.
Time frame: 7 days after surgery
Successful occluder implantation was defined as successful implantation of occluder and routine postoperative hospitalization that there were no serious adverse events related to surgery.
Time frame: 180 days after surgery
Complete occlusion was defined as the Transthoracic echocardiography (TTE) showing occlusion 180 days after surgery The position and shape of the apparatus were normal, and no horizontal atrial shunt was observed. The results of Contrast transthoracic echocardiography (cTTE) were reviewed there was no right-to-left shunt, that is, no microbubbles in the left heart cavity after Valsalva and resting state.
Time frame: 360 days after surgery
Success rate of effective occlusion was defined as: Transthoracic echocardiography (TTE) showed the position and shape of the occluder 360 days after the operation Normal condition, no horizontal atrial shunt; Reexamination by Contrast transthoracic echocardiography (cTTE) showed no or few results in other words, there were no microbubbles or less than 10 microbubbles in the left heart cavity after Valsalva and resting state.
Time frame: 360 days, 2 years, 3 years, 4 years, 5 years after surgery
Cryptogenic stroke was defined as a new focal cerebral ischemia confirmed by neuroimaging (cranial MRI or CT), which was performed After extensive vascular, cardiac, and blood evaluation, non-atherosclerotic, cardiogenic, or arteriolar obliterators were identified Cerebral infarction caused by the diagnosis of exclusion.
Time frame: 360 days, 2 years, 3 years, 4 years, 5 years after surgery
All-cause death is defined as death from any cause during the follow-up period.
Time frame: 360 days, 2 years, 3 years, 4 years, 5 years after surgery
atrial fibrillation and atrial flutter
Time frame: 360 days, 2 years, 3 years, 4 years, 5 years after surgery
Arterial embolism, Atrioventricular block III degree, heart abrasion, infective endocarditis, severe hemolytic anemia, etc.);
Time frame: 360 days, 2 years, 3 years, 4 years, 5 years after surgery
Device defects refer to unreasonable risks that may endanger human health and safety under normal use of medical devices in clinical trials, such as label errors, quality problems and failures.
Contact information is provided by the study sponsor or research team.
Lifetech Scientific (Shenzhen) Co., Ltd.
Industry
A Prospective, Multi-center, Randomized, Controlled Non-inferiority Clinical Trial to Evaluate the Safety and Efficacy of Cera™ Patent Foramen Ovale Occluders.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07172464
Brain Diseases, Cardiovascular Abnormalities
Los Angeles, California, United States
View Trial DetailsNCT07724171
Arrhythmias, Cardiac, Atrial Fibrillation
Seoul, South Korea
View Trial DetailsNCT07698951
Brain Diseases, Cardiovascular Abnormalities
Belgrade, Serbia
View Trial DetailsNCT05907694
Brain Diseases, Cardiovascular Abnormalities
Québec, Quebec, Canada
View Trial Details