Skip to main content
OpenTrials
Recruiting

NCT Number: NCT07698951

Evaluating Percutaneous Repair Of The Atrial Septum With A Novel PFO Occluder: The PROTEA-PFO OUS Study

The goal of this clinical trial is to test a new heart device called P3 Occluder System in patients who have a small opening between the upper chambers of the heart (called a Patent Foramen Ovale or PFO) and have experienced a stroke that may be related to this heart opening. The main question it aims to answer is:

• Is the P3 Occluder System safe and effective for closing a PFO in patients who have had a stroke that could be related to a PFO.

Participants will:

* Undergo the procedure to implant the P3 Occluder System, if deemed appropriate. * Visit their doctor at 1 month, 3 months, 6 months, and 1 year after the procedure for follow up exams. * Answer a phone call from study staff at 2 years and 3 years after the procedure to answer a survey.

Recruiting

Interested in participating?

Request Info

Key information

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient must be ≥ 18 and ≤ 65 years of age
  • Diagnosis of PFO, defined as visualization of microbubbles per TEE in the left atrium within three cardiac cycles from the right atrial opacification demonstrating right-to-left shunting at rest and/or during Valsalva release.
  • Ischemic stroke, defined as acute focal neurological deficit, presumed to be due to focal ischemia and confirmed by MRI or CT to have a neuroanatomically relevant cerebral infarct.
  • Modified Rankin score (mRS) ≤ 3.
  • Appropriate PFO anatomy for implantation of the investigational device as evaluated and determined by independent committee.
  • Patient is willing and capable of providing informed consent.
  • Prior to index procedure (7-day window), persons of childbearing potential must have a negative pregnancy test.

Exclusion criteria

  • Other identifiable causes of stroke, including but not limited to aortic arch plaques (protruding >4 mm into the lumen), large artery atherosclerotic disease proximal to the territory of the index stroke, an established cardioembolic source, small-vessel occlusive disease, or arterial dissection, presence of left atrial appendage thrombus.
  • Other arteriopathy of the intracranial or extracranial vessels with >50% stenosis proximal to the territory of the index stroke.
  • Intracardiac thrombus or tumor.
  • Myocardial Infarction (MI) or unstable angina within the previous 180 days.
  • Life expectancy < 2 years.
  • Left ventricular aneurysm or akinesis.
  • Moderate to severe mitral valve stenosis or severe mitral regurgitation.
  • Aortic valve stenosis (mean gradient >20 mmHg) or severe regurgitation.
  • Active endocarditis or other infection that may preclude implantation of the investigational device.
  • Any valve vegetation or Lambl's excrescence of any left-sided valve.
  • Left ventricular dilated cardiomyopathy with LVEF <35%.
  • Another source of right-to-left shunts identified at baseline, including an atrial septal defect and/or fenestrated septum and pulmonary arteriovenous malformation.
  • History of atrial tachycardia, atrial fibrillation or flutter, AV block, or ventricular arrhythmia requiring antiarrhythmic medication, pacemaker, or AICD.
  • Severe renal failure ( Stage 4 CKD, eGFR <30) or patient requiring dialysis.
  • Severe liver disease (e.g., documented cirrhosis or active hepatitis).
  • Severe lung insufficiency (e.g., need for supplemental oxygen or chronic steroid medications).
  • Uncontrolled hypertension, defined as sustained elevated blood pressure >140/90 mm Hg.
  • Severe pulmonary artery hypertension, defined as pulmonary systolic pressure of >50mmHg.
  • Uncontrolled hyperglycemia, defined as HbA1c value >8% (IFCC: >64 mmol/mol).
  • Increased bleeding risk such as severe liver failure, active peptic ulcer, proliferative diabetic retinopathy, history of severe bleeding (e.g.: gastrointestinal bleeding, macroscopic hematuria, intraocular bleeding, intracranial or cerebral hemorrhage), or other history of bleeding or coagulopathy.
  • Known hypercoagulable state that would require full anticoagulation. Minimum testing to include lupus anticoagulant, anticardiolipin antibodies, beta-2-glycoprotein, homocysteine.
  • Subjects contraindicated for aspirin or clopidogrel.
  • Subjects not able to discontinue anticoagulation for indications other than then index stroke.
  • Any disorder in the investigator's opinion that could interfere with compliance of safety evaluation or require premature discontinuation of antiplatelet regime post-implantation, as well as any severe concurrent illness that would limit life expectancy (e.g., malignancies).
  • Currently an active subject in an investigational drug or device study that could confound the results of this study.
  • Any significant valve dysfunction that contraindicates PFO closure or increased pulmonary vascular resistance/severe pulmonary hypertension.
  • Contraindication for transesophageal echocardiography (TEE) or intracardiac echocardiography (ICE).
  • Any prior percutaneous cardiovascular intervention for AF ablation.
  • Known nickel allergy that, in the opinion of the investigator, poses a safety risk with regards to participation in the trial.

Treatment and study plan

Recross P3 Occluder (P3O) System

Device

The Recross P3 Occluder (P3O) is being developed for the purpose of transcatheter closure of a patent foramen ovale (PFO) to reduce the risk of recurrent ischemic stroke in patients with PFO-associated stroke.

Primary outcomes

  1. Effective PFO Closure

    Time frame: 6 months

    Effective PFO Closure, at index procedure and at 6 months as measured by TEE, as adjudicated.

  2. Adverse Cardiovascular Events

    Time frame: 30 days

    Occurrence of significant adverse events including cardiac death, myocardial infarction, and stroke within 30 days post-procedure

Secondary outcomes

  1. Rate of device-related or procedure-related Serious Adverse Events (SAEs)

    Time frame: 30 days; 6 months

    Rate of device-related or procedure-related Serious Adverse Events (SAEs) at 30 days. Rate of device-related or procedure-related Serious Adverse Events (SAEs) at 6 months.

  2. Correct device position

    Time frame: 6 months

    Correct device position as assessed at 6 months on echocardiography, assessed by TTE or TEE.

Study contacts

Contact information is provided by the study sponsor or research team.

VP, Clinical Affairs

CONTACT

[email protected]

1.646.583.0352

Sponsors and collaborators

Lead sponsor

Recross Cardio, Inc.

Industry

Collaborators

  • SCIRENT Clinical Research and Science d.o.o.

Registry information

Acronym: PROTEA-PFO OUS

Important dates

Study start
2026
Primary completion
2027
Study completion
2029
First posted
Jul 13, 2026
Registry last updated
Jul 13, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.