Hospital Beata María Ana
Madrid, 28041, Spain
NCT Number: NCT05138185
Hemiparetic gait is characterized by strong asymmetries that could severely affect the quality of life of stroke survivors. This asymmetry is due to motor deficits in the paretic leg and the resulting compensations in the non-paretic limb.
In this study, the investigators aim to evaluate the effect of actively promoting gait symmetry in hemiparetic patients by assessing the behavior of both paretic and non-paretic lower limbs. To this end, the investigators use a unilateral active Knee-Ankle-Foot Orthosis able to assist the paretic limb of hemiparetic patients during gait.
The system is able to synchronize its action with the movement of the unassisted joints, promoting a natural and intuitive interaction. The device generate the assistance according to two differents strategies: (1) Replicating the movement of the helathy leg or (2) Inducing a healthy gait pattern on the paretic leg.
The hypothesis is that a proper and natural interaction between the user and the exoskeleton would enable the patients to consider the robot action as a part of their own gait capability, improving their gait quality as consequence. Hemiparetic asymmetry is not only due to impairments in the affected limb, but also it is the consequence of biomechanical compensatory mechanisms that might arose in the non-paretic leg. We aim to assess the adaptation process of the subject to the exoskeleton assistance, and to evaluate the effects of such human-robot interaction in both paretic and non-paretic legs.
Looking for future studies?
Notify Me18 year–85 year
All sexes
Interventional
Not applicable
Madrid, 28041, Spain
The prototype is equipped with sensors that provide information on system variables that are used for its control in real-time, such as the flexion angle of the robot joint or the interaction torque between user and robot. In addition, the gait kinematic of the user is measured by Inertial Measurement Units (IMUs) and the contact of both feet with the floor by Force Sensing Resistors (FSRs).
The system uses an Adaptive Frequency Oscillator to estimate the continuous gait phase of the contralateral limb and synchronically assists the paretic leg following two different control strategies: (1) Replicating the movement of the sound leg (Echo Strategy) or (2) Inducing a healthy gait pattern on the paretic leg (Pattern strategy). The action of the robot depends on the gait phase of the assisted leg: during stance the robot reinforces the limb so the system composed of the leg and the exoskeleton can load the user's weight and not collapse, while during the swing phase the robot guides the limb's movement according to the Assisted-As-Needed (AAN) paradigm creating a force tunnel around the prescribed trajectory.
Healthy subjects also performed a previous trial under variable gait speed (VariableSpeed). They walked over the treadmill as in the NoExo condition, although the gait speed randomly varies from 1km/h to 3km/h in 0.2km/h steps for 15 seconds at least.
Both researchers monitor fidelity to the intervention by direct supervision.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Ischemic or hemorragic stroke that lead to hemiplegic gait or healthy subjects without gait impairements. Same number os subjects is recruited
Exclusion criteria
Subjects were instructed to walk on a treadmill at a constant speed during trials of 5 minutes. All subjects carried out four trials: (1) NoExo: subjects only wore the sensors to acquire their basal motion; (2) Free: subjects wore the exoskeleton although the actuator was mechanically decoupled, so it enabled the free movement of the knee; (3) Echo: the device provided gait assistance following the Echo-control strategy; and (4) Pattern: the device provided gait assistance following the Pattern strategy. During trials, patients wore a safety harness that did not support any weight. Previously to the execution of the trials, the gait velocity was self-selected by the subjects to a comfortable level. Subjects rested between trials for five minutes. Healthy subjects also performed a previous trial under variable gait speed. They walked over the treadmill as in the NoExo condition, although the gait speed randomly varies from 1km/h to 3km/h in 0.2km/h steps for 15 seconds at least.
Time frame: During the last two minutes of the intervention
The joints motion is measured by Inertial Sensors
Time frame: During the last two minutes of the intervention
The joint motion is measured by Inertial Sensors
Time frame: During the last two minutes of the intervention
Data is collected from floor contact events detected by FSRs
Spanish National Research Council
Other Gov
Evaluation of the Effects of the Unilateral Assistance Provided by a Robotic Knee Exoskeleton in the Gait Symmetry of Healthy Subjects and Hemiparetic Patients.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04673838
Hemiparesis/Hemiplegia (One Sided Weakness/Paralysis), Hemiplegia
Denizli, Turkey (Türkiye)
View Trial DetailsNCT05138211
Hemiparesis/Hemiplegia (One Sided Weakness/Paralysis), Hemiplegia
Madrid, Spain
View Trial DetailsNCT06107010
Brain Diseases, Cardiovascular Diseases
Créteil, France
View Trial DetailsNCT05887440
Brain Diseases, Cardiovascular Diseases
Rennes, France
View Trial Details