Aim: The aim of this study is to compare the T-Scan digital occlusal analysis system and the occlusal analysis mode of the CEREC Omnicam system, which is mainly used for design/ production, using the data recorded at the centric occlusion position.

Material-Method: Occlusal recordings were obtained from healthy 20 females and 20 males aged 18-25 at the centric occlusion position. Records were saved as .jpeg format and transferred to Adobe Photoshop CS6 program. Blue, green, and red colors (shown by the same color codes in both systems) representing light, intense and tight contacts, respectively, were evaluated in terms of the pixel counts. For statistical comparison the differences between the systems Independent Sample T-Test and, between the genders, One Sample T- Test were used (α = 0.05).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–25 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Gazi University Faculty of Dentistry

Ankara, 06510, Turkey (Türkiye)

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Individuals with no missing teeth (teeth numbers 18, 28, 38, 48 were excluded from the evaluation), no local or systemic disorders that could prevent the bite, and no disorder determined as a result of the TMJ examination.

Exclusion criteria

-

Treatment and study plan

Digital Occlusal Recording with T-Scan

Device

Occlusal contact recordings of all the teeth were obtained digitally under conditions of maximum bite force and centric occlusion only with the T-Scan (T-Scan III, version 9.1, Tekscan Inc., South Boston, USA).

Digital Occlusal Recording with Cerec Omnicam

Device

Occlusal contact recordings of all the teeth were obtained digitally under conditions of maximum bite force and centric occlusion only with the CEREC Omnicam™ (version 4.2, Sirona Dental Systems, New York, USA).

Primary outcomes

  1. Comparing the levels of accuracy of the occlusal analysis mode included in the software of CEREC Omnicam and the T-Scan occlusal analysis system.

    Time frame: 6 months

    In both systems, the data of contact intensity were defined with a color scale of blue to red where blue showed the lowest intensity and red the highest. The contact area images obtained from both systems were recorded in .jpeg format and were then transferred to the Adobe Photoshop CS6 program (Adobe Systems, USA) for comparisons to be made.

    The number of pixels in the contact areas of the upper and lower jaws of each subject in all the recordings obtained with the T-Scan and CEREC Omnicam systems were determined using the Adobe Photoshop CS6 pixel-based photographic procedure program.

Sponsors and collaborators

Lead sponsor

Gazi University

Other

Registry information

Official study title

COMPARISON OF SENTRIC OCCLUSION DATA OBTAINED FROM TWO DIFFERENT COMPUTER-ASSISTED RECORDING METHODS

Important dates

Study start
2019
Primary completion
2019
Study completion
2019
First posted
Mar 15, 2021
Registry last updated
Mar 17, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.