This is a prospective randomised open-label study with the aim to compare the visual performance of the trifocal FineVision® IOL versus the extended range of vision Symfony® IOL after phaco-emulsification cataract surgery.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
Alexandria, Egypt
With the advent of a new intraocular lens (IOL) materials, technologies and advanced optics, higher spectacle independence after surgery is now possible.
Multifocal IOLs work by splitting light into different foci, which is known to generate photic effects. Trifocal optics, which have been available on the European market since 2010, offer spectacle independence in most cases. Typically, visual acuity is maintained throughout the whole range of vision from distance to near vision, and general patient satisfaction has proven that trifocal IOLs are well tolerated by patients.
Patients having irregular corneal astigmatism, large pupils and weak zonules were considered unsuitable candidates for multifocal IOLs, while patients who aim for spectacle independence and with low pre-operative regular astigmatism were considered to be good candidates.
The Fine Vision IOL (PhysIOL®; Liège, Belgium) is a diffractive trifocal IOL that provides an intermediate focus at 1.75 D and a near focus at 3.5 D (both at the IOL plane). This corresponds to a nominal intermediate add of approximately +1,15 D and near add of about 2,25 D at the corneal plane, depending on the geometry of the patient's eye. This intermediate focal point is expected to improve patient satisfaction relative to bifocal IOLs, since bifocal IOLs have a greater drop off in visual acuity (VA) in the intermediate range. There is a concern that the addition of a third focal point may increase halos, However, a relatively small percentage of energy is dedicated to intermediate vision when compared to distance and near vision. The trifocal diffractive structure asymmetrically directs incident light to distant (50%) intermediate (20%) and near (30%) focal points, independent of pupil diameter (up to 4,5 mm).
The FineVision is an aspheric trifocal IOL composed of 25% hydrophilic acrylic material with a blue light and ultraviolet light blocker. It has a total diameter of 10,75 mm and an optic body diameter of 6,15 mm.
The Tecnis Symfony is an extended range of vision IOL based on diffractive achromatic technology. The IOL has an achromatic diffractive pattern that elongates the focus and compensates for the chromatic aberration of the cornea. According to the manufacturer, halos are not expected with this IOL, because it provides an elongated focal area rather than one or various focal points. The IOL has a biconvex wavefront-designed anterior aspheric surface and a posterior achromatic diffractive surface. The total diameter of the IOL is 13.0 mm, and the optic zone diameter is 6.0 mm. It is an ultraviolet-filtering hydrophobic acrylic material with a refractive index of 1,47 at 35° C.
This is a prospective randomised open-label study with the aim to compare the visual performance of the trifocal FineVision® IOL versus the extended range of vision Symphony® IOL after phaco-emulsification cataract surgery.
All patients will undergo and complete preoperative ophthalmologic examinations including refractive status, uncorrected and corrected near and distance visual acuities, biometry and keratometry.
Postoperative, all patients will receive topical antibiotic treatment for 1 week and topical steroid tapered treatment for 4 weeks as well as NSAID topical treatment for 4 weeks. All patients will be followed up after 2 days, 1 week and 3 months.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Implantation of of PhysIOL trifocal FineVision® POD F IOL
Implantation of the Abbott Medical Optics, Inc. Tecnis Symfony® IOL
Time frame: 3 months postoperative
CDVA is measured with ETDRS charts placed in 6m distance with best aided corrective glasses according to International Standards Organization (ISO) 11979-7:2014. This assessment is done monocularly.
Time frame: 3 months postoperative
UDVA is measured with ETDRS charts placed in 6m distance according to International Standards Organization (ISO) 11979-7:2014. This assessment is done monocularly.
Time frame: 3 months postoperative
UIVA is measured with ETDRS charts placed in 65cm distance. The examination is done without corrective glasses and according to International Standards Organization (ISO) 11979-7:2014. This assessment is done monocularly.
Time frame: 3 months postoperative
DCIVA is measured with ETDRS charts placed in 65cm distance with corrective glasses for far distance according to International Standards Organization (ISO) 11979-7:2014. This assessment is done monocularly.
Time frame: 3 months postoperative
UNVA is measured with ETDRS charts placed in 35cm distance. The examination is done without corrective glasses and according to International Standards Organization (ISO) 11979-7:2014. This assessment is done monocularly.
Time frame: 3 months postoperative
DCNVA is measured with ETDRS charts placed in 35cm distance with corrective glasses for far distance according to International Standards Organization (ISO) 11979-7:2014. This assessment is done monocularly.
Time frame: 3 months postoperative
To assess the visual acuity for different distances, defocus curves under photopic light conditions are measured. This test is performed with best distance corrected refraction and spherical additions ranging from -4.0 D to 0.0 D. This examination is performed monocularly.
Time frame: 3 months postoperative
Contrast Sensitivity under photopic light conditions using the CSV-1000 contrast test.
Time frame: 3 months postoperative
For this study, the validated and verified questionnaire VFQ-25 (National Eye Institute) will be used. The VFQ-25 consists of a base set of 25 vision- targeted questions representing 11 vision-related constructs (General Health, General Vision, Ocular Pain,Near Activities, Distance Activities, Vision Specific (Social Functioning, Mental Health, Role Difficulties, Dependency), Driving, Color Vision, Peripheral Vision), plus an additional single-item general health rating question.
The minimum score is 0 and the maximum score is 100 for each construct. Higher values represent a better outcome.
Time frame: 3 months postoperative
The manifested refraction is measured by means of a phoropter. The data contains values for sphere, cylinder and axis of cylinder according to International Standards Organization (ISO) 11979-7:2014.
Beaver-Visitec International, Inc.
Industry
Visual Performance After Trifocal vs Extended Range of Vision Presbyopia-correcting Intraocular Lenses
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04699266
Cataract, Eye Diseases
Miyata, Japan
View Trial DetailsNCT03306355
Cataract, Eye Diseases
Makati City, Philippines
View Trial DetailsNCT03306342
Cataract, Eye Diseases
Brest, France
View Trial DetailsNCT03688425
Cataract, Eye Diseases
Makati City, Philippines
View Trial Details