3D printed module
ProcedureThe patients underwent 3D printed module-assisted lumbar pedicle screw placement using the Quandrant system, aiming to restore the stability of the spine.
NCT Number: NCT02970578
To explore the accuracy of 3D printed module assisted minimally invasive lumbar pedicle screw placement using Quandrant system, and verify its feasibility of reducing error rate of screw placement and postoperative complications.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
History and current related studies Pedicle screw fixation has been widely used in spinal surgery, such as spinal fractures, lumbar spondylolisthesis, scoliosis, lumbar spinal stenosis. However, difficulties in pedicle screw placement are unavoidable because of anatomical variations in the spinal structure and spinal degeneration. Consequently, the precise localization for screw placement is essential. If not, errors in screw placement will result in reduced strength or even failure of the internal fixation, which may lead to a series of injuries, including nerve root injury, dural sac tear, vascular injury and even spinal cord injury. To conclude, it is urgent to improve the accuracy of screw placement and reduce complications of screw placement in the pedicle screw fixation.
With the rapid adoption of digital medicine and 3D printing technology in orthopedic practice, 3D techniques, based on preoperative high-resolution CT scan data, can theoretically restore the three-dimensional structure of the bone. That is to say, the investigators can present a detailed description of the complex anatomical structure of the bone, to accurately make a preoperative plan and an intraoperative simulation. Numerous evidences have been achieved with digital three-dimensional reconstruction and 3D techniques to assist the posterior pedicle screw fixation in the treatment of spine lesions.
Adverse events Postoperative adverse events were recorded and reported to the Affiliated Hospital of Putian Hospital within 24 hours.
Proper therapeutic measures could be performed if the following adverse events occurred, including incision infection, back muscle pain, dural sac tear, vascular injury, nerve root injury, spinal cord injury, screw falling off and loosening.
Data collection, management, analysis, and open access Baseline data were collected at the day when the participants were enrolled in the study. Other data were collected preoperatively, intraoperatively, postoperatively and during the follow-up. All data were input using Epidata and saved electronically.
All data regarding this clinical study were preserved by the Affiliated Hospital of Putian University, China.
All data were statistically analyzed by professional statisticians who were responsible for completing an outcome analysis report that was submitted to the project manager who was responsible for completing a research report. An independent data monitoring committee was responsible for data monitoring and management throughout the entire trial.
Statistical analysis All data were statistically analyzed by statisticians using SPSS 19.0 software (IBM Corporation, Armonk, NY, USA) in accordance with the intention-to-treat principle.
Normally distributed measurement data were expressed as means, standard deviations, minimums, and maximums; non-normally distributed data were expressed as lower quartiles, medians, and upper quartiles.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The patients underwent 3D printed module-assisted lumbar pedicle screw placement using the Quandrant system, aiming to restore the stability of the spine.
Time frame: during the operation
To assess whether the screw placement by 3D printed module navigation achieves the desired results. The higher value indicates the higher accuracy.
Time frame: Baseline and month 6, month 24 after surgery
To observe the conditions of lumbar fixation.
Time frame: during the operation
To evaluate the speed of surgery. The shorter operation time indicates that this method is easier to operate.
Time frame: during the operation
To evaluate the conditions of intraoperative blood loss. Less blood loss indicates the higher improvement in the surgical quality by this method being studied.
The Affiliated Hospital of Putian University
Other
3D-printed Module-assisted Minimally Invasive Lumbar Pedicle Screw Placement: a Retrospective, Self-controlled, Open-label Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07706517
Brain Damage, Chronic, Brain Diseases
Saint-Etienne, France
View Trial DetailsNCT01961557
Brain Damage, Chronic, Brain Diseases
Bethesda, Maryland, United States
View Trial DetailsNCT02230072
Congenital Abnormalities, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
Stanford, California, United States
View Trial DetailsNCT02440984
Congenital Abnormalities, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
Rennes, France
View Trial Details