Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT06176170

VividWhite Glaucoma Implant (VW-51) Pivotal Study

The VividWhite Glaucoma Implant (VW-51) is a novel surgical implant designed to treat glaucoma. This study is a 12-month, 65-participant non-comparative multicentre study to assess the safety and effectiveness of the VW-51 implant.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Sydney Eye Hospital, Sydney, New South Wales, Australia

Loading trial locations.

About this study

A prospective multicentre non-comparative pivotal clinical study where all participants undergo treatment with a novel surgical implant (VW-51) and receive 12 months of clinical follow-up. The study aim is to assess the effectiveness, safety and participant experience of the VW-51 implant for the treatment of glaucoma. The study population will involve 65 adult participants with medically or surgically refractory glaucoma. The VW-51 implant is a leaf-shaped microfluidic device manufactured from flexible silicone, designed to be surgically implanted in the subconjunctival space, drain aqueous humor from the eye and reduce intraocular pressure to treat glaucoma.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Key Inclusion Criteria: Glaucoma in the study eye, meeting the following requirements:

  • Glaucoma is diagnosed by the investigator based upon untreated intraocular pressure, disc appearance and visual field abnormalities, and where the disease type is one of: Primary open angle glaucoma (POAG); Chronic angle closure glaucoma (CACG) where the eye is pseudophakic and a laser iridotomy has previously been performed; Pigmentary open angle glaucoma; Exfoliation open angle glaucoma; Rubeotic glaucoma that is treated and regressed/quiescent; Steroid-induced glaucoma; or Juvenile open angle glaucoma (JOAG).
  • There has been failure of previous treatment for glaucoma (it is 'refractory'), meeting ONE of the following requirements:

i. Failure of medical treatment: inadequate IOP control on maximum tolerated medical therapy.

ii. Failure of previous glaucoma surgery (not more than one operation) with trabeculectomy, Xen/PreserFlo, non-penetrating glaucoma surgery, a previously removed suprachoroidal drainage device, trabecular bypass (using iStents or Hydrus), or cilioablation.

c. The mean diurnal IOP at Screening/Baseline is ≥ 20 mmHg, and ≤ 40 mmHg.

d. The conjunctiva in the target quadrant is healthy, mobile and suitable for glaucoma surgery.

Key Exclusion Criteria: in the study eye:

  • Advanced glaucomatous optic neuropathy that threatens fixation, in the opinion of the investigator.
  • The glaucoma type is any of the following: Acute Angle Closure Glaucoma (AACG); Chronic Angle Closure Glaucoma where the eye is phakic; Congenital glaucoma; or Secondary glaucoma of any type not specified in the inclusion criteria, including inflammatory glaucoma, active neovascular/rubeotic glaucoma, traumatic glaucoma, Iridocorneal Endothelial (ICE) Syndrome, and silicone oil induced glaucoma.
  • Previous glaucoma surgery with: a tube-and-plate glaucoma drainage device (GDD, e.g. Molteno, Baerveldt, Ahmed, Schocket); an in-situ suprachoroidal implant; or multiple previous operations for glaucoma.
  • Cataract surgery or any other ocular surgery is indicated at the time of study intervention or is anticipated to be required during the study duration.
  • Central corneal endothelial cell density less than specified age-related thresholds at screening.
  • Intraocular silicone oil.
  • Significant corneal, retinal, inflammatory or infective ophthalmic pathology (full details specified in the protocol).

Treatment and study plan

VividWhite Glaucoma Implant (VW-51)

Device

Subconjunctival surgical implantation of the VW-51 implant in the study eye.

Primary outcomes

  1. Complete success by efficacy and safety criteria

    Time frame: Study completion (12 months)

    Efficacy Criteria:

    • Intraocular pressure (IOP) is less than or equal to 21 mmHg.
    • IOP is reduced by greater than or equal to 20% compared to baseline (mean diurnal).
    • Treatment with the same number or fewer classes of topical glaucoma medication than at baseline.
    • No requirement for: further glaucoma surgery indicated for efficacy (at any time during the study); or systemic/oral ocular hypotensive medication to achieve target IOP in the study eye (at any time during the study).

    Safety Criteria:

    • IOP is greater than or equal to 6 mmHg.
    • No adverse events of special significance in the study eye (as specified by the protocol; for example further glaucoma surgery indicated for safety).

Sponsors and collaborators

Lead sponsor

VividWhite Pty Ltd

Industry

Registry information

Official study title

A Prospective Multicentre Pivotal Clinical Study to Demonstrate the Efficacy and Safety of the VividWhite Glaucoma Implant (VW-51) for the Treatment of Glaucoma.

Important dates

Study start
2023
Primary completion
2026
Study completion
2026
First posted
Dec 19, 2023
Registry last updated
Nov 18, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.