The goal of this observational study is to learn about the long-term results of glaucoma stent surgery in men and women 18 or older who have had cataract and microstent surgery in the past 2 years at the Moran Eye Center. The main questions the study aims to answer are:
1. How often are microstents mispositioned? 2. What effect does microstent positioning have on intraocular pressure after surgery?
Participants will have a one-time clinic visit for an eye exam and Optical Coherence Tomography (OCT) .
From the eye exam and OCT, Researchers will assess and categorize the position of the microstents and assess the Schlemm's canal dilation.
Researchers will review the participants' medical records to acquire 2-year data for the following:
1. Surgeon type and level of experience (resident, fellow, attending ophthalmologist) 2. Proportions of proper gonioscopic placement intraoperatively for each surgeon group 3. Effectiveness of surgery, based on change in intraocular pressure (IOP) from baseline medicated IOP, number of IOP-lowering medications the patient was able to discontinue, and rate of need for additional glaucoma surgery.
This study is active but is not currently recruiting participants.
18 year–100 year
All sexes
Observational
Murray, Utah, 84107, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Both the Hydrus microstent and iStent Inject W are used in combination with cataract surgery, in order to help lower intraocular pressure for patients with open-angle glaucoma. The microstent is a small flexible device that is inserted into the eye during cataract surgery in order to improve the outflow of fluid from the eye.
Time frame: Two years post stent placement
Positioning of each participant's stent(s) will be evaluated by anterior segment OCT at the one-time clinical study visit.
iStent Inject W mispositions are defined as: microstent protrusion (entire conical head not within canal), stent completely buried in the trabeculae, or not seen (i.e. 0 or only 1 stent). If the iStent position is located but the examiner is unsure if it is positioned correctly, it will be counted as misposition. If the iStent is not seen, an in office gonioscopy will be performed to confirm results. Visualization of three stents is not considered a misposition.
Hydrus mispositions are defined as: distal tip not in canal, at least 1 window not in canal, or trabecular microstent not within transition zone.
The between group difference of mispositioned stents will be calculated in percentage.
Time frame: Two years post stent placement
The Schlemm's canal is a circular lymphatic-like vessel in the eye that maintains fluid homeostasis by draining aqueous humor from the eye into the systemic circulation. If the canal is blocked, the pressure in the eye can increase, resulting in glaucoma. Dilation will be visualized on OCT and graded on a numerical scale 1-3 (1=dilated, 2=some dilation, 3=no dilation) at the one-time study visit.
Time frame: Two years post stent placement
IOP is measured in millimeters of mercury (mmHg). A retrospective chart review will be conducted to acquire 2-year data to determine the change in each participant's IOP from baseline. The between group difference of change in IOP will be calculated in percentage.
Time frame: Two years post stent placement
A retrospective chart review will be conducted to determine how many IOP lowering medications each patient is using at 2 years post-stent placement compared to the number of IOP lowering medications they were using prior to stent placement. The between group difference of reduction in number of medications will be calculated in percentage.
Time frame: Two years post stent placement
A retrospective chart review will be conducted to determine the percentage of patients who had additional glaucoma surgery by the two-year post stent placement timepoint. The between group difference in number of patients needing additional glaucoma surgery will be calculated in percentage.
Time frame: Two years post stent placement
There will be a sub-analysis of the percentage of mispositions (primary endpoint) by level of surgeon experience. A retrospective chart review of the intraoperative note will determine if the primary surgeon was a resident or non-resident (attending or fellow).
Time frame: Two years post stent placement
The intraoperative notes at the time of stent placement will include confirmation of proper stent placement via gonioscopy. At the time of the study visit, stent placement will be assessed via anterior segment OCT. The number of correctly positioned stent placements will be reported in percentages.
University of Utah
Other
Post-operative Anterior Segment OCT Evaluation of Trabecular Microstent Positioning and the Impact on Intraocular Pressure
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06806332
Eye Diseases, Glaucoma
Boston, Massachusetts, United States
View Trial DetailsNCT07604428
Apnea, Eye Diseases
Olomouc, Czechia
View Trial DetailsNCT06689696
Eye Diseases, GLAUCOMA 1, OPEN ANGLE, D (Disorder)
Fullerton, California, United States
View Trial DetailsNCT03057301
Eye Diseases, Glaucoma
Edinburgh, Midlothian, United Kingdom
View Trial Details