Skip to main content
OpenTrials
Completed

NCT Number: NCT04800887

Visual Outcomes and Contrast Sensitivity in Patients Implanted With Tecnis Eyhance Intraocular Lens

To compare visual outcomes for various distances, reading speed, contrast sensitivity, glare occurence, defocus curve and subjective satisfaction in patients implanted with the extended depth of focus lens (Tecnis Eyhance) in one eye and monocal aspheric lens (Tecnis ZCB00) in second eye. Patients undergo visit in 3,6 and 12 months after the surgery.

Completed

Looking for future studies?

Notify Me

Key information

Age range

40 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Faculty hospital Kralovske Vinohrady

Prague, Czech Republic, 11000, Czechia

About this study

The goal of refractive cataract surgery is to remove the opacity, or cataract and to produce the desired refractive outcome. In most cases, the desired outcome is an emmetropic eye, or an eye that sees 20/20 Snellen for distance vision post-surgery with the implant of a monofocal IOL. This, however, does not offer much in the way of intermediate and near vision. The increased desire for simultaneous distance, intermediate and near vision has increased the popularity of multifocal IOLs (MIOLs). However MIOLs provide visual acuity for all distances, they has occurence of optical phenomena such as glare and halo and lower contrast sensitivity. Extended depth of focus (EDOF) lens should provide distance vision as good as monofocal lens and intermediate vision better than monofocal but without any optical phenomenon or decreased contrast sensitivity.

This study is conducted from 11/2019 to 08/2021 in the Ophthalmology department of Faculty Hospital Kralovske Vinohrady in Prague. The research protocol was explained to all participants and informed consent was signed before enrolling patient to the study. The study was approved by the Ethics Committee of Faculty Hospital Kralovske Vinohrady and will enrolled up to 25 patients with presence of cataract in both eyes.

Bilateral clear corneal phacoemulsification and IOL implantation is performed by one surgeon using the same technique in both eyes. The surgical process involved topical anesthesia, superior 3-step clear corneal incision (2,2mm), 5,0mm curvilinear capsulorhexis, phacoemulsification, bilateral irrigation- aspiration and IOL implantation. One eye is implanted with EDOF IOL second eye with monofocal IOL. Type of IOL is chosen randomly and double masked.

Patients are scheduled for visit at 3,6 and 12 months after the surgery.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • presence of cataract in both eyes
  • no other ocular pathology affecting visual acuity
  • bilateral phacoemulsification cataract surgery was arranged for both eyes
  • corneal astigmatism up to 0,75 cylinder (measured by IOL Master biometry)
  • dioptric power of both selective lens within 1,5 D range in one patient
  • selecting IOL power between 18 D and 27 D power range

Exclusion criteria

  • complicated cataract
  • corneal opacities or irregularities
  • amblyopia
  • anisometropia
  • coexisting ocular pathologies
  • glaucoma
  • history of ocular surgery
  • refusal or unable to maintain follow-up

Treatment and study plan

TECNIS Eyhance intraocular lens

Device

Cataract surgery and implantation with extended depth of focus intraocular lens

Monofocal intraocular lens Tecnis ZCB00

Device

Cataract surgery and implantation with monofocal intraocular lens

Primary outcomes

  1. Comparison of visual acuity between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

    Time frame: 12 months

    • uncorrected distance visual acuity (UDVA)
    • corrected distance visual acuity (CDVA)
    • uncorrected near visual acuity (UNVA)
    • distance corrected near visual acuity (DCNVA)
    • corrected near visual acuity (CNVA)
    • uncorrected intermediate visual acuity (UIVA)
    • distance corrected intermediate visual acuity (DCIVA)
  2. Comparison of reading speed between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

    Time frame: 12 months

    Monocular reading speed (Salzburg reading desk for 66cm and 80cm)

  3. Difference in contrast sensitivity between eyes with EDOF IOL and monofocal IOL

    Time frame: 12 months

    Contrast sensitivity - CSV (contrast sensitivity vision) 1000 device- monocularly, mesopic, without glare Contrast sensitivity measurement on Glaretester- monocularly- with and without glare

  4. Comparison of defocus curve between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

    Time frame: 6 months

    A defocus curve that measures visual acuity should be obtained by using the best corrected distance refraction and then defocusing the image in 0.5 increments from +1.5 to -2.5 diopter with spherical plus and spherical minus trial lenses (i.e.,+1.5 D, +1.0 D, +0.5 D, 0.00 D, -0.5 D, -1.00 D, . . . ,-2.50 D) with visual acuity recorded at each change in correction.

Secondary outcomes

  1. Questionaire

    Time frame: 6 months

    Questionaire based on Catquest-9SF (9-item short-form) questionaire with special questions of feeling difference in vision in each eye for various distances Contains questions for activities for various distances with scale of difficulty of doing activity without glasses from 1-4 (1= Yes, very great difficulty, 4= No, no difficulty and Cannot decide answer).

    Contains more 3 questions for feeling difference in visual acuity between eyes.

  2. Change in intermediate visual acuity in eyes implanted with EDOF IOL

    Time frame: 3 and 12 months

    • uncorrected intermediate visual acuity (UIVA) - photopic condition
    • distance corrected intermediate visual acuity (DCIVA)- photopic condition
  3. Change in reading speed in eyes implanted with EDOF IOL

    Time frame: 3 and 12 months

    Salzburg reading desk for 66cm and 80cm

  4. Change in contrast sensitivity in eyes implanted with EDOF IOL

    Time frame: 3 and 12 months

    Contrast sensitivity - CSV (contrast sensitivity vision) 1000 device- mesopic, without glare Contrast sensitivity measurement on Glaretester - with and without glare

Sponsors and collaborators

Lead sponsor

Faculty Hospital Kralovske Vinohrady

Other Gov

Registry information

Official study title

Comparison of Visual Outcomes and Contrast Sensitivity in Patients Implanted With Tecnis Eyhance IOL (Intraocular) and Tecnis Monofocal IOL

Important dates

Study start
2019
Primary completion
2021
Study completion
2021
First posted
Mar 16, 2021
Registry last updated
Oct 12, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.