Predicting Intraocular Lens Tilt Using OCT Measurements and Partial Least Squares Regression Modelling

During cataract surgery an artificial intraocular lens (IOL) is implanted in the eye to replace the lens and to correct the refraction for distance vision. Misalignment of IOLs can cause severe loss of visual quality. Different types of misalignment are known. Tilt, one type of IOL misalignment is thought to play a negative role for the optical performance in eyes with IOL designs, especially, if they have aspheric, toric, or multifocal optics.

Various methods to measure IOL misalignments have been described. Studies assessing the IOL position have used subjective grading methods at the slit lamp examination or a Scheimpflug camera to assess IOL decentration and tilt. The subjective grading at the slitlamp may display considerable variability between examiners. This method is more qualitative than quantitative and does not allow fine resolution when reporting IOL tilt. The fact that the patient has no standardized target to focus on makes the method even less reliable. Scanning methods such as Scheimpflug photos require a very well dilated pupil exceeding 6mm to assess the IOL position. Additionally, it can be difficult to identify the anatomical structures of the eye that need to be used as points of reference. Scheimpflug camera images have been used for assessing IOL tilt previously, but erroneous results, often due to corneal magnification, have diminished their widespread use. Another possibility to assess tilt is the use of Purkinje reflexes. The light reflections of Purkinje images at ocular surfaces to evaluate ocular alignment have recently been utilized. Since light is reflected at all interfaces of media with a difference in refractive index, these reflections, called Purkinje images, can be used to assess tilt and decentration of IOLs. Two different clinically applicable Purkinjemeter system provide the measurement of IOL decentration and tilt. The main problem with Purkinje meters is accessibility, as there are only a few prototypes available worldwide.

The most recently developed method for tilt quantification is the use of optical coherence tomography. This method has several advantages compared to the previous methods: OCT based devices are available in most clinics, the resolution of modern OCT devices is high, and the measurements are reproducible.

Aim of this study is to measure tilt with two modern OCT based devices and one Scheimpflug camera and to predict the post-operative tilt using partial least squares regression. This method was developed by Wold and introduced to ophthalmology previously.

Completed

Looking for future studies?

Notify Me

Key information

Age range

21 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Matthias Bolz

Linz, Upper Austria, 4020, Austria

About this study

During cataract surgery an artificial intraocular lens (IOL) is implanted in the eye to replace the lens and to correct the refraction for distance vision. Misalignment of IOLs can cause severe loss of visual quality. Different types of misalignment are known. Tilt, one type of IOL misalignment is thought to play a negative role for the optical performance in eyes with IOL designs, especially, if they have aspheric, toric, or multifocal optics. For example, in the case of aspheric IOLs, it appears that even slight amount of tilt may result not only in the loss of the effect of reducing spherical aberrations but in more severe cases even a worsening of the optical quality compared to spherical IOLs. In the case of toric IOLs, tilt introduces higher order aberrations potentially mimicking astigmatism. In the case of multifocal IOLs, tilt increases higher order aberrations, which leads to decreased visual quality.

Various methods to measure IOL misalignments have been described. Studies assessing the IOL position have used subjective grading methods at the slit lamp examination or a Scheimpflug camera to assess IOL decentration and tilt. The subjective grading at the slitlamp may display considerable variability between examiners. This method is more qualitative than quantitative and does not allow fine resolution when reporting IOL tilt. The fact that the patient has no standardized target to focus on makes the method even less reliable. Scanning methods such as Scheimpflug photos require a very well dilated pupil exceeding 6mm to assess the IOL position. Additionally, it can be difficult to identify the anatomical structures of the eye that need to be used as points of reference. Scheimpflug camera images have been used for assessing IOL tilt previously, but erroneous results, often due to corneal magnification, have diminished their widespread use. Another possibility to assess tilt is the use of Purkinje reflexes. The light reflections of Purkinje images at ocular surfaces to evaluate ocular alignment have recently been utilized. Since light is reflected at all interfaces of media with a difference in refractive index, these reflections, called Purkinje images, can be used to assess tilt and decentration of IOLs. Two different clinically applicable Purkinjemeter system provide the measurement of IOL decentration and tilt. The main problem with Purkinje meters is accessibility, as there are only a few prototypes available worldwide.

The most recently developed method for tilt quantification is the use of optical coherence tomography. This method has several advantages compared to the previous methods: OCT based devices are available in most clinics, the resolution of modern OCT devices is high, and the measurements are reproducible.

Due to the fact that tilt has an influence on visual quality, the prediction of the post-operative tilt could improve IOL power calculation significantly, especially for toric IOLs. In the literature, the prediction of tilt was shown to be acceptable for the orientation of tilt, but not for the amount of tilt. Furthermore, there is disagreement concerning the fact, if the amount of tilt increases or decreases after cataract surgery.

Aim of this study is to measure tilt with two modern OCT based devices and one Scheimpflug camera and to predict the post-operative tilt using partial least squares regression. This method was developed by Wold and introduced to ophthalmology previously.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Planned cataract surgery in one or both eyes
  • Above 21 years of age

Exclusion criteria

  • Combined surgery (cataract plus glaucoma/vitreoretinal/corneal surgery)
  • Best corrected distance visual acuity below 0.05 Snellen
  • Pathologies that could have an influence on the post-operative tilt, such as pseudoexfoliation syndrome or previous ophthalmic trauma, or other reasons for phakodonesis.
  • Previous ophthalmic surgery that could have an influence on post-operative tilt, such as pars plana vitrectomy
  • In case of pregnancy (pregnancy test will be taken preoperatively in women of reproductive age)

Treatment and study plan

optical coherence tomography

Other

the study releated measurements will be performed: IOLMaster 700, Casia 2 and Pentacam HR.

Other names: biometry (IOL Master700), Casia2, Pentacam HR

Primary outcomes

  1. post operative IOL tilt

    Time frame: 8 weeks post cataract surgery

    Predicting the post-operative tilt using PLS regression

Secondary outcomes

  1. Comparison of tilt prediction

    Time frame: 8 weeks post cataract surgery

    Bilateral comparison of tilt prediction

  2. comparion of three measurement methods

    Time frame: 8 weeks post cataract surgery

    Comparison between the three measurement methods concerning amount of tilt, orientation of tilt and tilt prediction

  3. Comparison of tilt pre- versus post operative

    Time frame: pre operative at screening and 8 weeks post cataract operation

    Change of tilt from pre-operatively to post-operatively

Sponsors and collaborators

Lead sponsor

Johannes Kepler University of Linz

Other

Registry information

Official study title

Predicting Post-operative Intraocular Lens Tilt Using Optical Coherence Tomography Measurements and Partial Least Squares Regression Modelling

Acronym: Tilt

Important dates

Study start
2022
Primary completion
2023
Study completion
2023
First posted
Mar 12, 2024
Registry last updated
Mar 12, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.