The purpose of this study is to compare visual performance and quality of life (QOL) following bilateral implantation of a novel non-diffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof® IQ Vivity, Alcon, TX, USA) and a trifocal IOL (Acrysof® IQ PanOptix, Alcon, Fort Worth, TX) in a prospective comparative interventional case series.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Ankara, 06490, Turkey (Türkiye)
Developments in cataract surgical devices and intraocular lenses (IOL) increased patient expectations and changed the practice patterns in ophthalmology. Nowadays, cataract surgery is considered as a refractive surgery. With multifocal IOLs, spectacle independence can be achieved with a good distance, intermediate and near visual acuity. This is associated with increased quality of life after cataract surgery.The most important disadvantages of multifocal IOLs are loss of contrast sensitivity and photic phenomena such as glare and halo. Although multifocal IOLs are more frequently associated with photic disturbances than monofocal IOLs, the trifocal IOLs have improved performance in photic phenomena when compared to bifocal IOLs. Recently, a new technology known as extended depth of focus (EDOF) IOLs have been developed. These lenses create a single elongated focal point to enhance the depth of focus, improving intermediate vision without compromising distance vision. Although EDOF IOLs provide better intermediate distance vision when compared to monofocal IOLs, near vision is not as good as trifocal IOLs. The most important advantage provided by the EDOF technology is lower rate of photic disturbances than trifocal IOL designs. The aim of this study was to compare the visual performance and patient-reported quality of life (QOL) outcomes following bilateral implantation of a novel non-diffractive wavefront shaping EDOF IOL (AcrySof® IQ Vivity, Alcon Research, TX, USA) and a trifocal IOL (AcrySof® IQ PanOptix, Alcon Laboratories, Fort Worth, TX).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Each participant underwent bilateral sequential cataract surgery and bilateral implantation of a novel non-diffractive EDOF IOL (n=26) or a trifocal IOL (n=26). The interval between the first and second-eye surgeries was 1 to 3 weeks. The patients selected the IOL model after they were fully informed regarding the advantages and disadvantages of each IOL, by their surgeon. Their degree of interest in greater spectacle freedom at far, intermediate, and near distances, as well as their daily activities such as frequency of night driving or reading habits were discussed. The possibility of photic disturbances was described and explained as well.
Time frame: postoperative third month
uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity (DCIVA), distance corrected near visual acuity (DCNVA)
Time frame: postoperative third month
The monocular defocus curves were evaluated under photopic conditions using defocusing lenses from +0.50 D to -4.00 D in 0.50 D steps. The measurements were performed by adding the lenses to the CDVA.
Time frame: postoperative third month
Monocular and binocular contrast sensitivity was assessed with the Pelli-Robson chart under photopic conditions at 3 meters.
Time frame: postoperative third month
Reading speed was measured using the validated Turkish version of the MNREAD chart in photopic illumination conditions. It was recorded as number of words read by the patient in one minute (words per minute-wpm).
Time frame: postoperative third month
Dysphotopsia was assessed by the Quality of Vision (QoV) questionnaire developed by McAlinden et al. The QoV is a validated Rasch-adjusted questionnaire in which patients are asked to rate specific dysphotopsia items depicted in standard photographs. Patients score each item (0, 1, 2, or 3) in relation to how frequent, severe, and bothersome their symptoms are (30 items in total). Lower QoV scores indicate a better quality of vision.
Time frame: postoperative third month
The vision-related QOL was assessed three months after the surgery by the VF-14 QOL questionnaire that was administered face-to-face by a trained researcher (İK). The grading scale was as follows: 0, no difficulty; 1, a little difficulty; 2, moderate difficulty; 3, quite difficult; 4, impossible to perform. Special care was taken not to influence the patients and to ensure that each question was fully understood.
Baskent University Ankara Hospital
Other
Comparison of Visual Performance and Quality of Life With a Novel Non-diffractive Extended Depth-of-focus IOL and a Trifocal IOL
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07500272
Cataract, Eye Diseases
Chon Buri, Thailand
View Trial DetailsNCT05411341
Cataract, Eye Diseases
Alexandroupoli, Evros, Greece
View Trial DetailsNCT06590272
Cataract, Eye Diseases
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT06305338
Cataract, Eye Diseases
Linz, Upper Austria, Austria
View Trial Details