Skip to main content
OpenTrials
Completed

NCT Number: NCT04619940

Validity and Reliability of iPhone Application in Internal Rotation Measurement

The validity and reliability of active internal rotation ROM measurement of shoulder with smartphone in patients with shoulder pain was investigated.

Completed

Looking for future studies?

Notify Me

Key information

Age range

40 year–70 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Istanbul Medeniyet University Faculty of Medicine, Physical Medicine and Rehabilitation Department

Istanbul, 34732, Turkey (Türkiye)

About this study

Eighteen patients with shoulder pain who applied to the Physical Medicine and Rehabilitation, shoulder subspecialty outpatient clinic who agreed to participate in the study and 18 volunteers who had not experienced shoulder pain before enrolled in the study. Participant age range was determined as 40-70 years.

The IHandy® app is a free app with a visual display similar to that of the digital inclinometer in terms of digital size. In this study, due to its prevalence in the literature and its use in clinics, manual goniometer (gold standard) was chosen to be compared with this iPhone application.

The participants were asked to lie on the bed in supine position with shoulder to be measured at the edge of the bed. The measured shoulder was positioned at 90 degrees abduction, 90 degrees elbow flexion and forearm at neutral position. The participant was asked to bring the wrist closer to the bed in the direction of the little finger, and was measured at the angle that the shoulder could not move without lifting the arm. In the measurement made with the application, the phone was held parallel to the ulna and the value displayed on the screen was recorded. The participant were asked to repeat the movement if his/her shoulder lift up of bed, straightened his/her elbow, or did anything that would disrupt her movement pattern.

Each measurement was repeated 3 times and after 2 weeks the control measurements were made by repeating 3 times.

Measurements were conducted separately in different cabinets without seeing each other for each participant by 1 physical medicine and rehabilitation specialist and 1 physiotherapist. The measurements were recorded in separate locations until all participants were completed.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient with shoulder pain
  • 40-70 years old
  • Agreed to participate the study

Exclusion criteria

  • <40 years old or >70 years old
  • Not agreed to participate

Treatment and study plan

iHandy application

Diagnostic Test

The IHandy® app is a free app with a visual display similar to that of the digital inclinometer in terms of digital size. In this study, due to its prevalence in the literature and its use in clinics, manual goniometer (gold standard) was chosen to be compared with this iPhone application.

Standard Goniometer

Diagnostic Test

While measuring with goniometer, the pivot point of the goniometer was placed on the olecranon, the immobile rod of the goniometer was kept parallel to the bed, while the moving rod was kept parallel to the ulna, the angle was recorded at the end point of the movement.

Primary outcomes

  1. iHandy application

    Time frame: 6 months

    The IHandy® app is a free app with a visual display similar to that of the digital inclinometer. In the measurement made with the application, the phone was held parallel to the ulna and the value displayed on the screen was recorded as range of motion value.

Sponsors and collaborators

Lead sponsor

Istanbul Medeniyet University

Other

Registry information

Official study title

Validity and Reliability of iPhone Application in Active Internal Rotation Measurement of Shoulder in Patients With Shoulder Pain

Important dates

Study start
2018
Primary completion
2018
Study completion
2019
First posted
Nov 6, 2020
Registry last updated
Nov 6, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.