NCT Number: NCT06176677

Use of a Low-cost Video Laryngoscope on Manikin

Videolaryngoscopy has become essential in airway management, providing improved glottis visualization and reducing intubation attempts. Proficiency in using videolaryngoscopes, especially those with hyperangulated blades, is crucial for challenging intubation cases. However, successful intubation with hyperangulated blades requires continuous training due to their unique shape. Despite the benefits, the high cost of commercial videolaryngoscopes limits their use, prompting the exploration of a cost-effective alternative-a self-built laryngoscope using a USB borescope. The study aims to compare its training effectiveness with a commercial hyperangulated blade videolaryngoscope, emphasizing accessible training options. The evaluation involves testing both devices on a Laerdal® intubation mannequin, focusing on the time to glottis visualization and the time to complete intubation.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year–70 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Santa Maria Maddalena Hospital

Volterra, Pisa, 56048, Italy

About this study

Videolaryngoscopy has become integral in airway management, providing improved visualization of the glottis and reducing the number of intubation attempts. Proficiency in the use of videolaryngoscopes is essential, particularly in cases of difficult intubation. Videolaryngoscopes equipped with hyperangulated blades facilitate enhanced visualization, even in the most challenging scenarios. However, successful intubation using these blades requires adequate training due to their unique shape. While hyperangulated blades offer excellent views around the curvature of the tongue, their upward perspective from the base of the tongue can pose challenges in tube delivery. Therefore, continuous training is essential to achieve proficiency with these particular blades.

Despite the advantages, the high cost of commercially available videolaryngoscopes poses a barrier to regular use and training, especially in resource-limited settings. This study introduces a cost-effective alternative-a self-built laryngoscope using a Universal Serial Bus (USB) borescope. The objective is to compare its training effectiveness with that of a commercial hyperangulated blade videolaryngoscope, underscoring the significance of accessible training options.

The Glidescope videolaryngoscope and a custom-built laryngoscope equipped with a USB borescope blade will undergo testing. The evaluation will be conducted by 30 emergency and operating room personnel following a brief training course in videolaryngoscopy, using a Laerdal® intubation mannequin. Both devices will utilize size 4 hyperangulated blades with identical curvature angles. Assessment endpoints will encompass the duration required for glottis visualization and the time needed for the entire intubation process.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

emergency and operating room personnel who have participated and completed the videolaryngoscopy course -

Exclusion criteria

any temporary or permanent physical impediment to performing the requested maneuver or not having participated or completed the videolaryngoscopy course

-

Treatment and study plan

Videolaryngoscope

Device

We set as endpoint the time from insertion of each laryngoscope through the mouth to complete visualization of the glottis (T1) and the time to complete intubation manoeuvre(T2)

Boroscope

Device

We set as endpoint the time from insertion of each laryngoscope through the mouth to complete visualization of the glottis (T1) and the time to complete intubation manoeuvre(T2)

Primary outcomes

  1. compare the effectiveness of training between a commercial videolaryngoscope and a low cost videolaryngoscope

    Time frame: one hour

    Compare the training effectiveness between a commercial videolaryngoscope and a low-cost videolaryngoscope by measuring the time from the insertion of each laryngoscope through the mouth to the complete visualization of the glottis (T1) and the time taken for the entire intubation maneuver (T2) in the manikin, among 30 emergency and operating room operators .

Sponsors and collaborators

Lead sponsor

Azienda USL Toscana Nord Ovest

Other

Registry information

Official study title

Comparative Evaluation of Training Effectiveness Between Commercial Videolaryngoscope and Low-Cost Self Built Laryngoscope With Hyperangulated Blade

Important dates

Study start
2024
Primary completion
2024
Study completion
2024
First posted
Dec 20, 2023
Registry last updated
Mar 5, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)