The purpose of this study is to assess the applicability of using ultrasonography in confirmation of the position of the endotracheal tube (ETT) after intubated to patients.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Bangkok, 10700, Thailand
To assess the applicability of using ultrasonography as compared to routine portable CXR in confirmation of ETT position.
To determine the accuracy of ultrasonography in measuring the depth of ETT as compare to standard CXR method.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Sonosite MICROMAXXTM with linear probe L38e/10-5 MHz
Time frame: 1 hour
A transcricothyroid membrane view of the ultrasonography was chosen for confirmation of ETT depth measurement. Firstly, measured the distance from probe (skin) to anterior surface of ETT. Then, measured the distance from probe (skin) to balloon cuff level. Finally the depth of ETT (Distance from vocal cord to balloon cuff) was calculated by using Pythagorus rule.
Time frame: 1 hour
A transcricothyroid membrane view was chosen for confirmation of ETT position. Various glottic structures such as True Vocal Cord (TVC), False Vocal Cord (FVC), and arythenoid cartilage can be visualized.
Mahidol University
Other
Ultrasonography in Confirming Proper Position of Endotracheal Tube in Emergency Department at Siriraj Hospital: Applicability and Accuracy
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02691468
Endotracheal Tube Wrongly Placed During Anesthetic Procedure, Surgical Procedure, Unspecified
Daegu, South Korea
View Trial DetailsNCT03929445
Endotracheal Tube Wrongly Placed During Anesthetic Procedure, Intubation;Difficult
Cairo, Egypt
View Trial DetailsNCT07586592
Endotracheal Tube Wrongly Placed During Anesthetic Procedure
Cairo, Abbasseya, Egypt
View Trial DetailsNCT04216199
Endotracheal Tube Wrongly Placed During Anesthetic Procedure
Tanta, Egypt
View Trial Details