The purpose of this study is to compare difference of displacement between Polyvinyl Chloride(PVC) and Silicon double-lumen endobronchial tubes(DLTs) during changing position from supine to lateral in thoracic surgery.
Looking for future studies?
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Daegu, 42415, South Korea
Lung isolation and differential lung ventilation, resulting in collapse of operative lung and ventilation of non-operating lung (one lung ventilation; OLV) are essential for thoracic surgery in lung, esophagus and thoracic aorta.
DLT, consisted of tracheal and bronchial lumens, is commonly used to perform differential lung ventilation. The correct position of each lumen in trachea and main bronchus is essential for successful OLV. However, DLT displacement occurs commonly while patients are changed position from the supine to the lateral. The deleterious consequences of a malpositioned DLT can be substantial, even life-threatening including severe hypoxemia.
Considering displacement of DLT during position change and surgical traction, previous studies recommended endobronchial cuff of DLT should be positioned at 0.5cm below the tracheal carina when using left-sided DLT. However, it is based on the data from several research conducted by PVC DLT.
These days, Silicon DLT, different in material from PVC DLT, is also widely used in clinical practice. Silicon DLT is different in not only position of ballon but also distance of each lumen. Furthermore,there are no identified studies about the displacement of silicon DLT during patient position change in thoracic surgery.
Therefore, it is necessary to measure the movement of silicon DLT during positional change from supine to lateral for finding the proper positioning of DLT.
The investigators compare the difference of displacement between PVC DLT and silicon DLT distance during positional change from supine to lateral by fiberotic bronchoscope. And the investigators try to find proper position of PVC and silicon DLT, respectively, to perform safe and successful OLV during thoracic surgery.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
PVC DLT is type of double lumen tube that is composed of PVC
Other names: PVC double-lumen tube
silicon DLT is type of double lumen tube that is composed of silicon
Other names: silicon double-lumen tube
Time frame: from supine to lateral decubitus position during surgery
The tracheal distance was defined as the distance between the distal tip of the tracheal lumen and tracheal carina whereas the bronchial distance was defined as that between the bronchial carina and distal tip of endobronchial lumen. The displacement of DLT was determined by changes in tracheal and bronchial distances, obtained by subtracting supine measurements from lateral measurements and subtracting measurements at start of surgery from measurements at the end of surgery, respectively. Clinically significant displacement was defined when the DLT was deviated by more than 10 mm from the initial correct position, regardless of the direction of displacement.
Time frame: from supine to lateral decubitus position
The displacement of DLT was determined by changes in tracheal and bronchial distances, obtained by subtracting supine measurements from lateral measurements and subtracting measurements at start of surgery from measurements at the end of surgery, respectively. The critical malposition was defined when the DLT was required repostion for successful OLV during position change
Yeungnam University College of Medicine
Other
Comparison of Displacement Between Polyvinyl Chloride(PVC) and Silicon Double-Lumen Endobronchial Tubes(DLT) During Change of Position
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03929445
Endotracheal Tube Wrongly Placed During Anesthetic Procedure, Intubation;Difficult
Cairo, Egypt
View Trial DetailsNCT01373437
Disease Attributes, Emergencies
Bangkok, Thailand
View Trial DetailsNCT07586592
Endotracheal Tube Wrongly Placed During Anesthetic Procedure
Cairo, Abbasseya, Egypt
View Trial DetailsNCT04216199
Endotracheal Tube Wrongly Placed During Anesthetic Procedure
Tanta, Egypt
View Trial Details