Pan Am Clinic
Winnipeg, Manitoba, R3M 3E4, Canada
NCT Number: NCT01727739
Widening of the single tibial tunnel following ACL surgery with quadrupled hamstrings autograft may contribute to failure of the graft and/or present technical challenges secondary to bone loss in a revision setting (Getelman, 1999). As such, efforts should be made to minimize the incidence and magnitude of tibial tunnel widening without sacrificing the biomechanical properties of the graft construct. The purpose of this investigation is to examine the tibial tunnel widening relationship between bioabsorbable interference screws composed of poly-L-lactic acid (PLLA) alone and composite bioabsorbable interference screws composed of poly-L-lactic acid embedded with beta tricalcium phosphate (PLLA+TCP) utilized as tibial fixation devices.
Specifically the study has the following objectives: 1) To quantify the extent of tibial tunnel enlargement at 3-, 6- and 12-months post ACL reconstruction with autogenous quadrupled hamstring graft; 2) To determine if the incorporation of beta tricalcium phosphate to the bioabsorbable interference screw alters the observed magnitude of tunnel widening; 3) To hypothesize mechanisms for any observed differences between tibial fixation devices; and 4) To correlate tibial tunnel widening with clinical outcome status. It is hypothesized that the PLLA+TCP bioabsorbable interference screw will not be associated with a reduction in tibial tunnel widening around the implant but rather between the implant and articular surface, compared to the PLLA alone screw. It is also hypothesized that there will be no effect of observed tunnel widening on clinical outcomes or graft failure rates.
Looking for future studies?
Notify Me18 year–45 year
All sexes
Interventional
Not applicable
Winnipeg, Manitoba, R3M 3E4, Canada
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Linvatec PLLA+TCP tibial interference screw fixation will be used in ACL reconstruction.
Linvatec PLLA tibial interference screw fixation will be used in ACL reconstruction.
Time frame: 12 months post op
At 3-, 6- and 12-months post-operatively, subjects will undergo radiographic examination of their affected knee (standardized AP and lateral views) for analysis of tibial tunnel parameters. Radiographic analysis will be conducted by a single orthopaedic surgeon/fellow/resident blinded to subject group and clinical examination results. Parameters to be recorded and analyzed according to a standardized method: tibial tunnel diameter (max/min).
We will also look for: Evidence of lysis in the tunnel and changes in morphological features of tunnel over time
Time frame: 12 months post op
Completed at 3-, 6- and 12-months post operatively for subjective outcome measure.
Time frame: 12 months post op
Range of motion assessment at 3-,6-and 12-months post operatively.
Panam Clinic
Other
Tibial Tunnel Widening in ACL Reconstruction-Comparing Two Bioscrews: A Prospective Randomized Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03462823
ACL, ACL - Anterior Cruciate Ligament Rupture
Zurich, Switzerland
View Trial DetailsNCT07608575
ACL
Nibong Tebal, Pulau Pinang, Malaysia
View Trial DetailsNCT06167343
ACL, ACL Injury
Granada, Spain
View Trial DetailsNCT06529679
ACL, ACL Injury
Ann Arbor, Michigan, United States
View Trial Details