Aveir VR Leadless Pacemaker System
DevicePatients will undergo an attempted leadless pacemaker implant
NCT Number: NCT04559945
prospective, non-randomized, multi-center, international clinical study is designed to confirm the safety and effectiveness of the Aveir LP System in a subject population indicated for a VVI(R) pacemaker.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Foothills Medical Centre, Calgary, Alberta, Canada
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients will undergo an attempted leadless pacemaker implant
Time frame: 6 weeks
Complication is any device-or-procedure related serious adverse event, or serious adverse device effect, including those that prevented initial implantation. Complications possibly related or related to COVID-19 were excluded. Percentage of participants free from complications are reported
Time frame: 12 months
Complication is any device-or-procedure related serious adverse event, or serious adverse device effect, including those that prevented initial implantation. Complications possibly related or related to COVID-19 were excluded. The complication free rate reported describes the Kaplan-Meier estimate of the percentage of patients that had no complications at the given time point.
Time frame: 6 Weeks (Aveir VR Leadless Pacemaker arm)
Success Rate is percentage of subjects who have acceptable pacing threshold and sensing amplitudes, which are defined as pacing threshold <=2.0V at 0.4 ms pulse width and R-wave amplitude =>5.0 mV or => value at implant.
Time frame: 12 months
Success Rate is percentage of subjects who have acceptable pacing threshold and sensing amplitudes at 12-Month post-implant visit, which are defined as pacing threshold <=2.0V at 0.4 ms pulse width and R-wave amplitude =>5.0 mV or => value at implant.
Time frame: 3 month follow up
Temperature-based rate response feature was evaluated to determine whether an appropriate and proportional rate response was achieved during maximal effort graded treadmill exercise testing protocol (CAEP). Subjects were asked to perform a six-minute walk test to identify optimal sensor parameters prior to conducting a CAEP test. Exercise test data provide an estimate of the slope of the normalized increase in sensor-indicated rate versus normalized workload for each subject. Normalizing a variable eliminates the unit. Since both axes are normalized, there is no unit of measure. The vertical axis is derived from the difference of the sensor indicated rate at each exercise stage and the base rate, divided by the difference of the age-predicted maximum heart rate and base rate. Values on the horizontal axis are derived from the difference in the workload at each exercise stage and resting workload, divided by the difference of the maximum achieved workload and resting workload.
Time frame: 2 years
All-Cause Mortality through 2 years among subjects implanted with the Nanostim Leadless Pacemaker. The Nanostim Leadless Pacemaker is functionally similar to the Aveir VR Leadless Pacemaker, and was evaluated in The LEADLESS II IDE Study (Phase I) - NCT02030418. For detailed demographic and study information including adverse events, refer to NCT02030418
Abbott Medical Devices
Industry
The LEADLESS II IDE Study (Phase II): A Safety and Effectiveness Trial for a Leadless Pacemaker System
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05252702
Arrhythmia, Sinus, Arrhythmias, Cardiac
Scottsdale, Arizona, United States
View Trial DetailsNCT06542133
Arrhythmias, Cardiac, Bradycardia
Jonesboro, Arkansas, United States
View Trial DetailsNCT05327101
Arrhythmias, Cardiac, Bradycardia
Scottsdale, Arizona, United States
View Trial DetailsNCT07118358
AV Block, Arrhythmias, Cardiac
Ypsilanti, Michigan, United States
View Trial Details