Bursa Uludag University Hospital
Bursa, Nilüfer, Turkey (Türkiye)
NCT Number: NCT06378424
Aim: The aim of the present study was to examine the effect on venous dilation, procedure duration and pain severity of local hot, cold and vibration applications performed on the intervention area before peripheral intravenous catheterization in adults.
Methods: The study included 120 adults who were randomly selected between March and August 2023. One application group (n=30) received local hot application, one group (n=30) received local cold application, and one (n=30) received local vibration using the Buzzy® device. The applications, to the site of the peripheral intravenous catheterization, lasted one minute. The control group (n=30) the received standard peripheral intravenous catheterization application. The groups' venous dilation was assessed on the vein assessment scale and the level of pain felt during catheterization was assessed using a visual analog scale.
Looking for future studies?
Notify Me18 year–65 year
All sexes
Interventional
Not applicable
Bursa, Nilüfer, Turkey (Türkiye)
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Before peripheral intravenous catheterization, heat of approximately 40-42 o C was applied for 1 minute to the area of the procedure using a hot pack, which is one of the dry heat application methods. The heat application pack has a feature that it can maintain its temperature when taken out of hot water and does not disturb the person when it comes into direct contact with the skin. In order to apply heat to the individuals in this group, a pack of 11 x 19 cm is used. This pack is covered with cloth and contains a non-toxic gel, and is placed in hot water to prepare it for use. Because this pack is reusable, it was disinfected before and after each use.
Before peripheral intravenous catheterization, heat of approximately 40-42 o C was applied for 1 minute to the area of the procedure using a hot pack, which is one of the dry heat application methods. The heat application pack has a feature that it can maintain its temperature when taken out of hot water and does not disturb the person when it comes into direct contact with the skin. In order to apply heat to the individuals in this group, a pack of 11 x 19 cm is used. This pack is covered with cloth and contains a non-toxic gel, and is placed in hot water to prepare it for use. Because this pack is reusable, it was disinfected before and after each use.
With individuals in this group, the Buzzy® device was used to provide vibration. The Buzzy® device, at room temperature, was placed by the researcher on the peripheral intravenous catheterization application area before the application was performed. For one minute before the application, a slight, non-discomforting vibration was applied to the intervention area. As the Buzzy® device can be used more than once, it was disinfected after each use and before being used with another individual. In this study, the body of the device was used, and only vibration was applied to the individuals in this group.
Time frame: 6 months
A 10-cm vertical VAS was used to evaluate the severity of pain felt by the individuals during the procedure. One end indicated lack of pain and the other the most severe pain possible. Pain severity was evaluated in millimeters.
Time frame: 6 months
Vein Assessment Scale was used in the study to evaluate individuals' veins. There are five assessment steps: (1) veins are neither visible nor palpable, (2) veins are visible but not palpable, (3) veins are barely visible and palpable, (4) veins are visible and palpable, and (5) veins are clearly visible and easily palpable.
Time frame: 6 months
In the stages of the peripheral intravenous catheterization intervention of individuals in the application and control groups, a chronometer was started immediately after an automatic tourniquet was attached to the patient's arm. After catheterization was completed successfully and before the evaluation material was applied, the chronometer was stopped, and the procedure duration was recorded in the form of seconds on the data collection form.
Time frame: 6 months
weight in kilograms
Time frame: 6 months
height in meters
Uludag University
Other
The Effectiveness of Local Dry Cold, Hot and Vibration Applications During Peripheral Intravenous Catheterization Placement in the Emergency Unit
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07059429
Agnosia, Analgesia
Moscow, Russia
View Trial DetailsNCT06340776
Agnosia, Hysterectomy
Istanbul, Beykoz, Turkey (Türkiye)
View Trial DetailsNCT07712991
Agnosia, Nervous System Diseases
Islamabad, Pakistan
View Trial DetailsNCT07706036
Agnosia, Fractures, Bone
Ankara, Çankaya, Turkey (Türkiye)
View Trial Details