Hacettepe University
Ankara, Turkey (Türkiye)
NCT Number: NCT04494217
This will be a prospective clinical study conducted with the approval of the Clinical Research Ethics Committee.
The influence of phototherapy lights on the accuracy of pulse oximetry will be investigated.
Looking for future studies?
Notify Me0 day–28 day
All sexes
Observational
Ankara, Turkey (Türkiye)
Each patient's oxygen saturation will be measured non-invasively via a nondisposable polyethylene neonatal probe taped to the infant's palm, toe, or dorsum of the foot. The probe will be connected to an Massimo Rad97 pulse oximeter that is standardized at the factory. It runs through an automatic systems check when turned on and needs no further calibration before being used. The oxygen saturation measurements will be considered valid when there will be a normal plethysmographic waveform, a fullscale signal strength bar, and a stable heart rate closely approximating an independent electrocardiographic (ECG) pulse rate. The pulse oximeter works by using the technology of plethsmography which allows the detection of an arterial pulse) with oximetry (which measures oxygen saturation at specific wavelengths). The pulse oximeter will be placed on each infant as already described. After a stable pulse oximeter reading was obtained, the value will be recorded ("before") and then the probe will be covered with a standard disposable diaper, shiny side up. When the reading stabilized, the value will be recorded ("during") and then the diaper will be removed.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: The two data (''before'' and ''during'') will be recorded consecutively for each infant, when the reading stabilize. All measurements will be completed wiithin 6 months according to the study protocol calendar.
The two data points (percent oxygen saturation before and during covering of oximeter probe) for each patient will be compared.
Hacettepe University
Other
The Influence of Phototherapy Lights on the Measurement of Oxygen Saturation With Pulse Oximeter in Newborns.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07110987
Anemia, Anemia, Hemolytic
Latakia, Syria
View Trial DetailsNCT06687746
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Hyperbilirubinemia
Hodal, India
View Trial DetailsNCT06921330
ABO Incompatibility, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
Karabük, Karabük Province, Turkey (Türkiye)
View Trial DetailsNCT03741803
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Hyperbilirubinemia
Houston, Texas, United States
View Trial Details