Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07156409

The Clinical Application of Peripheral Embolization Coil Systems in Arteriovenous Embolization Within the Peripheral Vasculature

Evaluation of the Safety and Effectiveness of the Peripheral Embolization Coil System Manufactured by Suzhou Zhongtian Medical Instruments Co., Ltd. for the Treatment of Arteriovenous Embolization in the Peripheral Vasculature in a Real-World Setting

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

About this study

This study adopts a prospective, multicenter, single-arm target value design. It plans to enroll patients with peripheral arteriovenous diseases requiring embolization, who will be treated using the Peripheral Embolization Coil System manufactured by Suzhou Zhongtian Medical Instruments Co., Ltd. Follow-up assessments will be conducted during the procedure, prior to discharge, and at 30 days, 3 months, and 6 months post-operation to evaluate the safety and effectiveness of the Peripheral Embolization Coil System

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Aged 18 to 75 years (inclusive), regardless of gender;
  • Patients diagnosed preoperatively via imaging (including but not limited to ultrasound, CTA, MRA, DSA, etc.) with peripheral arteriovenous conditions requiring embolization therapy;
  • The visually estimated normal reference diameter of the target vessel is ≥ 3mm;
  • Patients or their legally authorized representatives are capable of understanding the study objectives, voluntarily participating in this study, providing signed informed consent, and able to comply with follow-up.

Exclusion criteria

  • The target vessel requires the concurrent use of other embolic materials (e.g., Gelfoam, embolic microspheres, liquid embolic agents, etc.);
  • Known definite history of allergy to platinum, tungsten metals, and/or any component of the investigational product;
  • Subjects with pre-existing severe cardiac, hepatic, renal, respiratory diseases, or coagulation disorders who are unsuitable for anesthesia or endovascular surgical treatment;
  • High-flow arteriovenous fistulas that may cause migration of the embolic material;
  • The target aneurysm is a blister aneurysm, dissecting aneurysm, mycotic (infectious) aneurysm, ruptured aneurysm, or aneurysm caused by connective tissue diseases;
  • Severe vascular stenosis or tortuosity, or anatomical anomalies where it is anticipated that the device will be difficult to navigate to the lesion site, or other uncommon anatomies that may interfere with device use;
  • The target vessel has undergone any previous embolization therapy or surgical intervention, or has recurrent disease;
  • Definite allergy, resistance, or contraindication to antiplatelet drugs, anticoagulants, contrast media, and/or anesthetics;
  • Females who are pregnant, breastfeeding, or planning to become pregnant within 6 months; males planning for parenthood within the next 6 months;
  • Subjects currently participating in other drug or device clinical trials who have not reached the trial endpoint;
  • Investigators deem the subject unsuitable for participation in this study.

Treatment and study plan

Peripheral Embolization Coil System

Device

Primarily used to block or reduce the blood flow velocity in the peripheral vascular system

Primary outcomes

  1. Rate of technical success (embolization of target vessel)

    Time frame: Immediately after the intervention

    Angiographic imaging confirmed successful occlusion of the target vessel segment with no blood perfusion.

Secondary outcomes

  1. Rate of treated vessel occlusion

    Time frame: 6 months

    Angiographic imaging confirmed successful occlusion of the target vessel segment with no blood perfusion.

  2. Target Vessel Re-intervention Rate

    Time frame: 30 days,3 months,6 months from procedure date

    The embolized segment of the target vessel requires re-intervention/surgical intervention.

  3. All-cause mortality rate

    Time frame: 6 months from procedure date

    Death from any cause

  4. Rate of Device/Procedure-Related Serious Adverse Events

    Time frame: Perioperative,30 days,3 months,6 months from procedure date

  5. Adverse Event/Serious Adverse Event Rate

    Time frame: 6 months from procedure date

Sponsors and collaborators

Lead sponsor

Suzhou Zenith Vascular Scitech Co., Ltd.

Industry

Collaborators

  • The First Affiliated Hospital of Soochow University

Registry information

Official study title

A Prospective, Multicenter, Single-Arm Target Value Study Evaluating the Safety and Effectiveness of a Peripheral Embolization Coil System for the Treatment of Arteriovenous Embolization in the Peripheral Vasculature in a Real-World Setting

Important dates

Study start
2025
Primary completion
2026
Study completion
2026
First posted
Sep 5, 2025
Registry last updated
Sep 5, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.