PerMed Stent Graft System In Surgical Operation
DevicePerMed Branch Stent Graft
Other names: Stanford A aortic dissection open surgery
NCT Number: NCT05659641
The purpose of the study was to evaluate the safety and efficacy of a branched type intraoperative stent system for the treatment of Stanford type A aortic dissection
This study is active but is not currently recruiting participants.
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Anhui Provincial Hospital, Hefei, Anhui, China
Types The clinical trial design was prospective, muticenter, open, randomized controlled design with an additional single group design.
Plan Before the randomized controlled trial, each center will enroll one subject as a learning curve case(only use PerMed double branched structures). 212 participants were planned to be enrolled from no less than 10 qualified clinical research institutions and randomly assigned 1:1 to the intraoperative stent systems of Endovastec and the branched type intraoperative stent systems of PerMed double branched structures. An additional 30 subjects were enrolled using a branched type intraoperative stent system with a single branch structure from PerMed, Beijing.
All enrolled participants were followed up clinically intraoperatively, before discharge or 30 days ± 7 days after procedure, 6 months ± 30 days after procedure, 12 months ± 30 days after procedure, and 2-5 years after procedure.Non inferiority of the trial product to the control product was assessed with the primary end point of all-cause mortality at 12 months after procedure. The statistical analysis and summary report will be conducted based on the 12-month follow-up data of all subjects, and the application for medical device registration will be carried out. The long-term efficacy and safety evaluation of the product will be carried out after long-term follow-up.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
PerMed Branch Stent Graft
Other names: Stanford A aortic dissection open surgery
CRONUS® Branch Stent Graft
Other names: Stanford A aortic dissection open surgery
Time frame: after procedure 1 year
Percentage of subjects who died from any cause within 12 months ±30 days
Time frame: Immediately after implantation
Refers to the proportion of successful device implantation. That is, the test product or control product was successfully introduced into the true lumen of the vessel and successfully released, the delivery system was successfully withdrawn, and the anastomosis was completed with the artificial vessel.
Time frame: Immediately after procedure
It refers to the proportion of subjects who have completed the expected surgical treatment
Time frame: 30 day
It refers to the proportion of dead subjects within 30 days (including 30 days) after operation
Time frame: 6 month, 1 year
Complete thrombosis refers to the rate of complete thrombosis of the entire aortic false lumen on arterial phase and delayed phase imaging.
Partial thrombogenicity refers to the rate of presence of thrombus in the false lumen but residual flow in the arterial and delayed phases. Details are described in the 2022 ACC guidelines for the diagnosis and management of AHA aortic disease.
Time frame: 1 year
The proportion of subjects with stenosis degree of left subclavian artery and/or left common carotid artery less than 50% within 12 months after procedure.
Time frame: 1 year
The proportion of participants with unexpected re intervention due to the trial or control device.
Time frame: 1 year
It refers to a cerebrovascular event caused by the implantation of the test product or control product, which shows partial or complete loss of movement or sensation, and lasts for more than 24 hours
Time frame: 1 year
It refers to the ratio of subjects with spinal cord functional defects caused by ischemia after the implantation of the experimental or control device. Except those caused by tumor, trauma, tuberculosis and other factors with clear causes
Time frame: 1 year
Renal hypofunction refers to the increase of serum creatinine (SCR) ≥ 50% compared with the basic value (SCR value in screening period) and (or) urine volume<0.5 ml/(kg · h)>6 h. Except for acute renal injury caused by poisoning and other clear causes.
Time frame: 30 day
It refers to the proportion of subjects who died of aortic dissection within 30 days (inclusive) after operation or within 30 days (inclusive) after the secondary intervention of target lesion
Time frame: 6month,1 year,5 year
It refers to the ratio of device related adverse events occurring after the implantation of the test product in the follow-up period to the total adverse events.
Permed Biomedical Engineering Co., Ltd
Industry
A Prospective, Multicenter, Open, Randomized Controlled, Non Inferiority Clinical Trial to Evaluate the Safety and Efficacy the Branch-based Intraoperative Stent System in the Treatment of Stanford A Aortic Dissection
Acronym: BROAD
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02306200
Acute Aortic Syndrome, Aneurysm
Ann Arbor, Michigan, United States
View Trial DetailsNCT03894033
Acute Aortic Syndrome, Acute DeBakey I Dissection
Berlin, State of Berlin, Germany
View Trial DetailsNCT03414866
Acute Aortic Dissection, Acute Aortic Syndrome
London, Ontario, Canada
View Trial DetailsNCT00583817
Acute Aortic Syndrome, Aneurysm
Boston, Massachusetts, United States
View Trial Details