Optison
DrugOptison is administered intravenously
Other names: Perflutren Microspheres Injectable Suspension, USP
NCT Number: NCT03740997
Study to determine the safety and appropriate dosage of OPTISON in pediatric participants since OPTISON has been tested in adult participants only during the clinical development
Looking for future studies?
Notify Me9 year–17 year
All sexes
Interventional
Phase 4
Phoenix Children's Hospital, Phoenix, Arizona, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Optison is administered intravenously
Other names: Perflutren Microspheres Injectable Suspension, USP
Time frame: Images were captured during the study echocardiogram (0 to 30 minutes) on Day 1 and blinded image evaluations (BIE) were carried out at the study core laboratory following image transfer
Visualization of each of the 12 segments of the LV wall in standard A4C and A2C views were measured by the qualitative EBD visualization scale: score 0 =no visualization of the LV endocardial border; 1 =poor visualization; 2 =fair visualization; 3 =good/optimal visualization. The total LV EBD score was calculated as the sum of the individual scores assigned to each of the 12 LV wall segment and the total score ranged from 0 (no visualization of the LV endocardial border) to 36 (good/optimal visualization). A higher score indicated better visualization. The total score of qualitative EBD visualization scale were reported by reader (independent blinded), non-contrast and dose levels.
Time frame: 0- 72 hours
An Adverse Event (AE) was any untoward medical occurrence in a participant administered a pharmaceutical product and which did not necessarily had to have causal relationship with treatment. TEAEs were defined as AEs that starts or worsens at or after the time of first dosing of OPTISON.
Time frame: Baseline (pre-dose), and at 10 and 60 minutes post last dose on Day 1
Systolic and diastolic blood pressure were measured from the arm contra-lateral to the site of OPTISON administration whenever possible and before measurement, participants rested for at least 5 minutes (if possible).
Time frame: Baseline (pre-dose), and at 10 and 60 minutes post last dose on Day 1
Before heart rate was measured, participants rested for at least 5 minutes (if possible).
Time frame: Baseline (pre-dose), and at 10 and 60 minutes post last dose on Day 1
Before respiratory rate was measured, participants rested for at least 5 minutes (if possible).
Time frame: Baseline (pre-dose), and at 10 and 60 minutes post last dose on Day 1
Oxygen saturation was measured by pulse oximetry. Before oxygen saturation was measured, participants rested for at least 5 minutes (if possible).
Time frame: From first dose (Day 1) of study drug to 60 minutes post last dose on Day 1
Participants underwent assessments including general appearance, respiratory, cardiovascular and neurological (motor function, level of consciousness, sensory function) examination. Any abnormal clinically significant physical examination findings were based on investigator decision.
Time frame: Baseline (pre-dose), and at 10 and 30 minutes post last dose on Day 1
Change from baseline in PR, QRS, QT, Bazett's formula corrected QT (QTcB), Fridericia's formula corrected QT (QTcF) and RR intervals expressed in millisecond (ms) were reported.
Time frame: Images were captured during the study echocardiogram (0 to 30 minutes) on Day 1 and blinded image evaluations (BIE) were carried out at the study core laboratory following image transfer
LVO peak contrast intensity was determined by readers (independent blinded) using a categorical scale as None, Low, Medium, High or Blooming, where, None = Absence of contrast signal; Low = Limited capacity to make a diagnostic assessment; Presence of contrast signal does not improve diagnostic interpretability to a great degree; Medium = Good capacity to make a diagnostic assessment; Contrast signal facilitates diagnostic interpretability to a good degree; High = Optimal capacity to make a diagnostic assessment; Contrast signal facilitates diagnostic interpretability to a high degree; Blooming = Oversaturation of the signal disrupts diagnostic interpretability. Tissue boundaries become challenging to delineate. There may be excessive acoustic shadowing in the far-field of the image. Number of participants by degree of LVO assessed by visual peak contrast intensity was presented by readers and dose levels.
Time frame: Images were captured during the study echocardiogram (0 to 30 minutes) on Day 1 and blinded image evaluations (BIE) were carried out at the study core laboratory following image transfer
Peak LV contrast filling for LVO was categorized as: 0 = none (0 percent [%] filling); 1 = faint (around 33% filling); 2 = intermediate (around 67% filling); 3 = full (100% filling) and data were presented by readers (independent blinded) and dose levels.
Time frame: Images were captured during the study echocardiogram (0 to 30 minutes) on Day 1 and blinded image evaluations (BIE) were carried out at the study core laboratory following image transfer
Contrast enhancement duration was determined from the time the contrast appeared in the LV to the time the contrast almost dissipated from the left chamber. 3 independent blinded reader performed evaluation.
Time frame: Images were captured during the study echocardiogram (0 to 30 minutes) on Day 1 and blinded image evaluations (BIE) were carried out at the study core laboratory following image transfer
Diagnostic confidence for the assessment of LV EBD and wall motion was scored for non-contrast and OPTISON-enhanced echocardiographic acquisitions separately using a 4-point scale which ranged from ranged 0 to 4, where 0 = no confidence, 1 = low confidence, 2 = moderate confidence, 3 = high confidence. A higher score indicates better confidence level. Data were presented by reader (independent blinded), non-contrast and dose levels.
Time frame: Images were captured during the study echocardiogram (0 to 30 minutes) on Day 1 and blinded image evaluations (BIE) were carried out at the study core laboratory following image transfer
Diagnostic confidence for the evaluation of LVEF was calculated using the formula: (end diastole volume - end systole volume)/(end diastole volume) was scored for non-contrast and OPTISON-enhanced echocardiographic acquisitions separately using a 4-point scale which ranged from 0 to 3, where 0 = no confidence, 1 = low confidence, 2 = moderate confidence, 3 = high confidence. A higher score indicates better confidence level. Data were presented by reader (independent blinded), non-contrast and dose levels.
GE Healthcare
Industry
A Phase 4, Open-Label, Non-Randomized, Multicenter Study to Evaluate Safety and Efficacy of Intravenous Administration of OPTISON™ for Contrast- Enhanced Echocardiography in Pediatric Patients
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06075407
Electrical Cardiometry, Fluid Resuscitation
Cairo, Egypt
View Trial DetailsNCT03938220
Electrical Cardiometry, Fluid Responsiveness
Tanta, ElGharbiaa, Egypt
View Trial DetailsNCT04521933
Transthoracic Echocardiography
Ústí nad Labem, Czechia
View Trial DetailsNCT04083924
Echocardiography, Education
Honolulu, Hawaii, United States
View Trial Details