Skip to main content
OpenTrials
Completed

NCT Number: NCT03938220

Electrical Cardiometry Compared to Transthoracic Echocardiography in Fluid Responsiveness in Sepsis

The aim of this study is to evaluate the diagnostic accuracy of electrical cardiometry (EC) for the noninvasive determination of fluid responsiveness in sepsis and agreement of (EC) compared to transthoracic echocardiography (TTE).

Completed

Looking for future studies?

Notify Me

Key information

Age range

19 year–65 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Tanta University Hospitals

Tanta, ElGharbiaa, 31511, Egypt

About this study

Usual investigations [complete blood count (CBC), C reactive protein (CRP), serum procalcitonin, serum lactate, arterial blood gases (ABG), blood culture, electrocardiogram (ECG) and liver and renal function tests] will be done.

Once the diagnosis of sepsis is definite and the patient develops hypotension, all patients will undergo simultaneous measurement by (EC) using the ICON_ device and (TTE).

Electrical cardiometry (EC) measurements: by the ICON_ hemodynamic monitor (ICON Cardiotronics, Inc., La Jolla, CA 92307; Osyka Medical GmbH, Berlin, and Germany, model C3, Serial no: 1725303). Four sensors of (EC) will be applied (1st: 5 cm above the base of the neck, 2nd: on the base of the neck, 3rd: lower thorax at the level of the xiphoid and 4th: 5 cm below the 3rd electrode at the level of the anterior axillary line). The ICON continuously displays heart rate, stroke volume, and cardiac output.

Transthoracic echocardiography (TTE) measurements: will be performed by using Philips (CX50 - Extreme edition) equipped with echo probe. SV of the left ventricle will be calculated using LVOT diameter (D) just below the aortic valve from parasternal long-axis view and velocity time integral (VTI) measured in left ventricle outflow tract (LVOT) from apical 5 chamber view (by pulsed wave Doppler), respectively. The machine's built-in software uses the formula ''(πD2/4) × VTI × HR'' to calculate CO.

Management of sepsis will be done according to surviving sepsis campaign guidelines in 2016 and its update 2018.

Fluid resuscitation will be 30 mL/kg of intravenous infusion of lactated ringer to be given within the first 3 h (≈5 mL/kg/30 min) guided by fluid responsiveness (fluid responder if SV increases by > 10% after the fluid challenge). If the patient becomes fluid non-responder, vasopressor infusion (norepinephrine 0.05-0.3µg/kg/min) will start. The end of the study is when mean arterial blood pressure > 65 mmHg (either by fluid or both fluid and vasopressor).

Who can participate

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age from 19 to 65 years old.
  • Clinical criteria of sepsis [acute change in sepsis-related organ failure assessment (SOFA) variables ≥ 2 points consequent to the infection which include: PaO2/FiO2 ratio < 300, Glasgow Coma Scale score < 15, mean arterial pressure (MAP) < 70 mmHg, serum creatinine >1.2 mg/dl or urine output < 0.5 ml/kg/h, serum bilirubin > 1.2 mg/dL, platelet count < 150 X 103 /µl].
  • Developing hypotension (mean arterial blood pressure ≤ 65 mmHg).

Exclusion criteria

  • Other causes of shock
  • Previous cardiac disease
  • Rhythm other than sinus rhythm or heart rate > 140 beats/min
  • Chronic renal failure.

Treatment and study plan

Electrical cardiometry

Device

Electrical cardiometry (EC) measurements: by the ICON_ hemodynamic monitor (ICON Cardiotronics, Inc., La Jolla, CA 92307; Osyka Medical GmbH, Berlin, and Germany, model C3, Serial no: 1725303). Four sensors of EC will be applied (1st: 5 cm above the base of the neck, 2nd: on the base of neck, 3rd: lower thorax at the level of the xiphoid and 4th: 5 cm below the 3rd electrode at the level of anterior axillary line). The ICON continuously displays HR, SV and CO.

Primary outcomes

  1. Diagnostic accuracy of electrical cardiometry to predict fluid responsiveness.

    Time frame: 24 hours

    Fluid resuscitation will be 30 mL/kg of intravenous infusion of lactated ringer to be given within the first 3 h (≈5 mL/kg/30 min) guided by fluid responsiveness (fluid responder if stroke volume increases by > 10% after the fluid challenge). If the patient becomes fluid non-responder, vasopressor infusion (norepinephrine 0.05-0.3µg/kg/min) will start. The end of the study is when mean arterial blood pressure> 65 mmHg (either by fluid or both fluid and vasopressor).

Secondary outcomes

  1. Agreement of electrical cardiometry with transthoracic echocardiography in the change of stroke volume before and after fluid challenge.

    Time frame: 24 hours

    Fluid resuscitation will be 30 mL/kg of intravenous infusion of lactated ringer to be given within the first 3 h (≈5 mL/kg/30 min) guided by fluid responsiveness (fluid responder if stroke volume increases by > 10% after the fluid challenge). If the patient becomes fluid non-responder, vasopressor infusion (norepinephrine 0.05-0.3µg/kg/min) will start. The end of the study is when mean arterial blood pressure> 65 mmHg (either by fluid or both fluid and vasopressor).

Sponsors and collaborators

Lead sponsor

Tanta University

Other

Registry information

Official study title

Validation of Electrical Cardiometry Measurements Compared to Transthoracic Echocardiography in Fluid Responsiveness in Sepsis

Important dates

Study start
2019
Primary completion
2021
Study completion
2021
First posted
May 6, 2019
Registry last updated
May 3, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.