NCT Number: NCT01168557

Stress Echo and Electric Impedance Tomography (EIT) Pilot Study

Electric Impedance Tomography (EIT) is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax.It is a radiation free, non- invasive and portable lung imaging technique. Impedance changes in lung ventilation as well as in lung perfusion can be shown. To investigate lung perfusion by EIT measurements, cardiac output measured by routinely undergone stress echocardiography at rest and stress are compared to parameters measured by EIT.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

Male

Study type

Interventional

Phase

Not applicable

Primary location

Medical Clinic I, University Hospital Aachen

Aachen, North Rhine-Westphalia, 52074, Germany

About this study

In 15 patients who routinely have to undergo stress echocardiography Electric Impedance Tomography (EIT) measurements are performed parallel to measurements of cardiac output at rest, low stress generated by a dosage of 10µg dobutamine, at peak generated by a dosage between 20-40µg dobutamine (individually)and at relaxation(pulse <100). Therefore prior to the examination a rubber belt with 16 integrated electrocardiographic electrodes is placed around the thorax at the fifth or sixth intercostal space, connected with an EIT device. EIT data are generated by application of a small alternating electrical current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. Changes due to ventilation as well as changes due to perfusion will be measured by EIT. Cardiac output will be retrospectively compared to parameters of the EIT. EIT data are stored in a database and pseudonymized evaluated in relationship to routinely measured stress echocardiography data.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • male patients >18 years who routinely have to undergo stress echocardiography
  • ejection fraction >50%
  • able to give informed consent

Exclusion criteria

  • restrictive lung diseases
  • active implants and heart pace makers and implanted converter defibrillator
  • foreign metallic objects in the thorax
  • Not adequate quality of imaging of stress echocardiography

Treatment and study plan

EIT (Electrical Impedance Tomography)

Device

EIT measurement; concomitant to stress echocardiography (about 45 minutes) EIT measurements (1 minute) are performed at rest, at low dobutamine stress, at peak and at relaxation

Primary outcomes

  1. influence of cardiac output on EIT measurements (feasibility)

    Time frame: single measurement of 45 minutes

    It will be investigated if a change in cardiac output, which is measured by stress-echocardiography by dobutamine, has an influence on the parameters determined by EIT measurements.

Sponsors and collaborators

Lead sponsor

RWTH Aachen University

Other

Registry information

Official study title

Stress Echo and Electric Impedance Tomography (EIT) Pilot Study to Investigate the Influence of Cardiac Output on Parameters of the EIT

Important dates

Study start
2010
Primary completion
2012
Study completion
2012
First posted
Jul 23, 2010
Registry last updated
Nov 27, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.