American University of Beirut Medical Center
Beirut, Lebanon
NCT Number: NCT05843565
The goal of this prospective randomized cross over clinical trial is to compare the difference in the percentage of glottic opening (POGO) between two different video laryngoscopy blades, the hyperangulated Cobalt blade and the straight Miller blade in neonates or small infants with body weight ≤ 5 kg and age ≤ 3 months.
The main questions it aims to answer are:
* Is there a significant difference in the POGO using the standard Miller video laryngoscope blade versus the non-standard hyperangulated Cobalt video laryngoscope blade in neonates and small infants? * Are there significant differences in the first attempt success rate at intubation, the number of attempts, the time to successful intubation, the type of blade used for successful intubation, and the occurrence of adverse events during intubation, such as episodes of bradycardia or desaturation?
40 (20 in each group) neonates or small infants with body weight ≤ 5 kg or age ≤ 3 months will be enrolled in one of the two groups over 2 years of work.
Researchers will compare the POGO and Cormack and Lehane (C&L) classification using the hyperangulated Cobalt blade versus the straight Miller blade to identify the technique that provides optimal glottic views and intubating conditions in this patient population, and thus improved patient's safety.
Looking for future studies?
Notify MeUp to 3 month
All sexes
Interventional
Not applicable
Beirut, Lebanon
A higher incidence of difficult airway has been reported in neonates and infants than in adults. Optimizing glottic view during tracheal intubation is very challenging in neonates and small infants and it is not clear whether the design of the intubating blade using video laryngoscopy has a major influence of the glottic view and subsequently on the success of intubation.
The primary objective of this study is to compare the difference in the percentage of glottic opening (POGO) between two different video laryngoscopy blades, the hyperangulated Cobalt blade and the straight Miller blade. The secondary objectives are the first attempt success rate at intubation, the number of attempts, the time to successful intubation, and the occurrence of adverse events during intubation, such as desaturation or bradycardia.
In this prospective randomized cross over clinical trial, 40 (20 in each group) neonates or small infants with body weight ≤ 5 kg or age ≤ 3 months will be enrolled in one of two groups over 1 year of work. In patients allocated to the Cobalt group, the POGO and Cormack and Lehane (C&L) classification will be recorded using video laryngoscopy with a Cobalt blade followed by an assessment using the Miller blade. In patients allocated to the Miller group, the POGO and C&L classification will be recorded using video laryngoscopy with a Miller blade followed by an assessment using the Cobalt blade. In both groups, intubation will be attempted during the second assessment. If the first attempt at intubation fails, the subsequent attempts will be left at the discretion of the attending anesthesiologist.
Data comparing straight and hyperangulated video laryngoscopy blades in neonates and small infants are limited. Both techniques are standard of care at our institution. This study will identify the technique that provides optimal glottic views and intubating conditions in this patient population, and thus improved patient's safety.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
GlideScope® VL (Verathon Inc, WA, USA) hyperangulated blade 2
standard Miller blade 0 or 1
Time frame: Intraoperatively
Percentage of Glottic Opening
Time frame: Intraoperatively
Cormack and Lehane classification for glottic view.
Time frame: Intraoperatively
Number of intubation attempts.
Time frame: Intraoperatively
Anesthesia timeline (seconds) from first intubation attempt to first EtCO2 detection
Time frame: Intraoperatively
Occurrence of events such as: Desaturation (SpO2 < 95%) and bradycardia.
American University of Beirut Medical Center
Other
Standard Versus Hyperangulated Video Laryngoscopy Blades for Intubation in Neonates and Small Infants: Evaluation of the Glottic View
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06727513
Airway Trauma, Intubation Complication
Beirut, Lebanon
View Trial DetailsNCT06656546
Disease Attributes, Emergencies
Istanbul, Turkey (Türkiye)
View Trial DetailsNCT06449924
Hematologic Diseases, Hemic and Lymphatic Diseases
Beirut, Lebanon
View Trial DetailsNCT06401486
Anesthesia, Intubation Complication
A Coruña, Spain
View Trial Details