NCT Number: NCT00655213

Spontaneous Atrio Ventricular Conduction Preservation

In case of sinus node dysfunction, it is often necessary to choose the safer option provided by a DDD pacemaker even though the most appropriate mode of pacing is AAI mode.

In addition to saving energy, the latter mode allows spontaneous ventricular activation, the haemodynamic consequences of which are, in most cases, better than those obtained with dual chamber pacing.

Recent studies as the MOST study suggest also that ventricular desynchronization imposed by right ventricular apical pacing even when AV synchrony is preserved increases the risk of atrial fibrillation in patients with SND. Similar results were already given by anterior studies (PIPAF) which, taking into account the percentage of ventricular pacing, suggested that AF prevention algorithm in combination with a preserved native conduction are efficient in reducing AF burden.

However, current practice is to implant a dual chamber pacemaker to prevent the risk of atrioventricular block (AVB) even if DDDR pacing with a fixed long AV delay was found inefficient in reducing ventricular pacing and was associated with a high risk of arrhythmias.

The Symphony 2550 cardiac pacemaker offers pacing modes that automatically switch from AAI(R) mode to DDD(R) or DDI(R) in event of severe atrioventricular conduction disorder, irrespective of whether or not these are accompanied by an atrial arrhythmia, returning spontaneously to AAI(R) mode as soon as the spontaneous AV conduction has resumed. These 2 particular modes are called the AAI SafeR and DDD/AMC (R) mode.

The main differences between both modes are that (i) AAI SafeR does not trigger any AV Delay after a sensed or paced atrial event which allows long PR intervals or even limited ventricular pauses with no switch to DDD(R), while (ii) DDD/AMC (R) is able to optimize AV Delay after switching to DDD(R) according to measured spontaneous conduction times and to provide an acceleration in case of vaso-vagal syndrome. This pacing mode has previously been assessed in clinical studies.

This study intends to demonstrate that the automatic modes switching significantly reduce the percentage of ventricular pacing in patients implanted with a spontaneous AV conduction and reduce the occurrence of atrial arrhythmias, on a mid-term follow-up period, in comparison to standard DDD pacing with long AVDelay.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

Onze lieve Vrouw ziekenhuis, Aalst, Belgium

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient has been primo-implanted with a Symphony™ 2550 or 2450 devices for less than 3 months
  • Patient with a normal spontaneous AV conduction at rest (PR < 250 ms)
  • Patient implanted for Sinus Node Dysfunction, Braycardia-Tachycardia Syndrome, carotid sinus syndrome/ vaso vagal syndrome or paroxistic AV Block
  • Patient implanted with a bipolar right-atrial lead and ventricular lead available in the local market
  • Patient has signed a consent form after having received the appropriate information

Exclusion criteria

  • Permanent 1st, 2nd or 3rd AV block
  • Patient having a medical status complying with one of the following cases
  • patient suffering from sustained ventricular arrhythmias
  • patient having sustained a myocardial infarction within the last month
  • patient having undergone cardiac surgery within the last month
  • patient suffering from severe aortic stenosis
  • patient suffering from unstable angina pectoris
  • patient presents with permanent atrial arrhythmias
  • Patient is not able to understand the study objectives and protocol or refuses to co-operate
  • Patient is not available for scheduled follow-up
  • Patient has a life expectancy less than one year
  • Patient is included into another clinical study
  • Patient is minor or a pregnant woman

Treatment and study plan

Symphony D 2450

Device

Symphony DR 2550

Device

Primary outcomes

  1. mean percentage of ventricular pacing between the randomized branches on a two-months period (M3 visit)

    Time frame: 2 months

  2. mean percentage of ventricular pacing between the studied groups during the whole study (up to 1 year).

    Time frame: 12 months

Secondary outcomes

  1. percentage of ventricular pacing two month after randomization versus the percentage reported at the end of the first month follow-up in AAIsafeR mode.

    Time frame: 12 months

  2. AF burden relatively to the branch of the protocol

    Time frame: 12 months

  3. evolution of conduction disturbances by documentings nature, number and duration of ario-ventricular blocks.

    Time frame: 12 months

Sponsors and collaborators

Lead sponsor

LivaNova

Industry

Registry information

Acronym: SAVER

Important dates

Study start
2003
Primary completion
2006
Study completion
2006
First posted
Apr 9, 2008
Registry last updated
Apr 9, 2008

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.