Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06503692

Scoring Balloon and High Pressure Balloon in the Treatment of Arteriovenous Graft Stenosis

This is a multicenter, prospective, randomized controlled clinical study. Patients with hemodialysis arteriovenous graft fistula stenosis will be recruited to explore whether the scoring balloon is superior to the high pressure balloon in treating such lesions, so as to provide a basis for optimizing the treatment of such lesions.

This study will be conducted in seven (7) clinical trial institutions, with a total of 140 subjects included. After randomization, the subjects will use either the scoring balloon dilatation catheter, developed and produced by DK Medical Technology Co., Ltd., or the peripheral balloon dilatation catheter for surgical treatment. Clinical follow-up will be carried out within 5 days, 3 months, 6 months, and 12 months after the procedure.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Beijing Tongren Hospital Affiliated to Capital Medical University, Beijing, Beijing Municipality, China

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Hemodialysis patients aged ≥18 and ≤80 years old, (Note: Hemodialysis patients in Singapore aged ≥ 21 and ≤80 years old);
  • AVG is mature and has successfully completed at least one hemodialysis treatment;
  • The target lesion is located in the AVG return vein and the venous side anastomosis;
  • The degree of stenosis of the target lesion is ≥50% (DSA visual inspection), and one of the following clinical indicators exists at the same time: Physical examination abnormalities include: open collateral veins, ipsilateral limb edema, changes in pulse characteristics, abnormal tremors, abnormal murmurs, etc.; Dialysis abnormalities include: increased venous pressure, new puncture difficulties, aspiration of thrombi, inability to reach target dialysis blood flow, prolonged haemostasis time after needle removal for 3 consecutive times, unexplained decrease in dialysis dose Kt/V (>0.2 units), decrease in brachial artery blood flow (brachial artery blood flow <650ml/min or decreased by 20% compared with the previous follow-up visit), etc.
  • The target lesion is primary or restenotic, consisting of one or more series of lesions, and the reference blood vessel diameter of the target lesion is between 4.0-8.0mm, and the total length of the target lesion is ≤80mm ;
  • The patient voluntarily signs the informed consent form.

Exclusion criteria

  • The target lesion is located in the feeding artery, arterial anastomosis, artificial blood vessel puncture site, cephalic venous arch, thoracic outlet or central vein;
  • A stent has been implanted in any part of the access or there is ipsilateral central vein stenosis or occlusion that affects the function of the access;
  • Severely calcified lesions that are not expected to be dilatable with balloons;
  • Acute thrombosis or chronic total occlusion of AVG occurred at the time of enrolment;
  • The target lesion or any part of the vascular access has received PTA treatment within the last month;
  • There are thicker branch veins in the vein opening of the end-to-side anastomosis;
  • Patients who have undergone major surgical treatment within 30 days before inclusion in the study;
  • Patients known to be allergic to or intolerant to contrast media;
  • Patients receiving glucocorticoids or immunosuppressants;
  • The patient's life expectancy is less than 1 year;
  • Patients planning kidney transplantation or switching to peritoneal dialysis;
  • The degree of stenosis in the puncture point area is >50%;
  • Patients with infection or other medical conditions that make the investigator think they are not suitable to participate in this study;
  • Those who have participated in clinical trials of other drugs or devices but have not completed them.

Treatment and study plan

DKutting PTA Scoring Balloon Dilatation Catheter

Device

The device consists of a balloon catheter with scoring elements (triangular cross-section) fixed to the surface of the balloon and distributed radially at every 120°. When the balloon is inflated, the expansion force is focused along the scoring elements, causing it to expand under lower balloon pressure.

Other names: Scoring Balloon

Peripheral Balloon Catheter

Device

The device is an over-the-wire (OTW) double-lumen balloon catheter. The balloon is inflated to a known diameter at a specified pressure.

Primary outcomes

  1. Target Lesion Primary Patency (TLPP) at 6 months post-procedure

    Time frame: 6 months

    TLPP is terminated by postoperative target lesion failure (TLF) (including the 5 mm range before and after the target lesion) or target lesion-related vascular access thrombosis.

    TLF is defined as the presence of at least one clinical indicator (defined according to the NKF-K/DOQI guidelines) caused by target lesion stenosis ( ≥50% stenosis of the target lesion assessed by contrast angiography or ultrasound), including physical examination abnormalities or dialysis abnormalities.

    Target lesion-related vascular access thrombosis is limited to: after the thrombus is removed during AVG thrombus treatment and before balloon dilatation, it is confirmed by ultrasound/DSA that the original target lesion has a stenosis ≥ 50%, or when the balloon is expanded with low pressure (<6 atm) during intraluminal treatment, obvious balloon residual waisting can be seen at the target lesion; simple mural thrombus at the puncture point or other parts of the graft needs to be ruled out.

Secondary outcomes

  1. Target Lesion Primary Patency (TLPP) at 12 months post-procedure

    Time frame: 12 months

    TLPP is terminated by postoperative target lesion failure (TLF) (including the 5 mm range before and after the target lesion) or target lesion-related vascular access thrombosis.

    TLF is defined as the presence of at least one clinical indicator (defined according to the NKF-K/DOQI guidelines) caused by target lesion stenosis ( ≥50% stenosis of the target lesion assessed by contrast angiography or ultrasound), including physical examination abnormalities or dialysis abnormalities.

    Target lesion-related vascular access thrombosis is limited to: after the thrombus is removed during AVG thrombus treatment and before balloon dilatation, it is confirmed by ultrasound/DSA that the original target lesion has a stenosis ≥ 50%, or when the balloon is expanded with low pressure (<6 atm) during intraluminal treatment, obvious balloon residual waisting can be seen at the target lesion; simple mural thrombus at the puncture point or other parts of the graft needs to be ruled out.

  2. Access Circuit Primary Patency (ACPP) at 6 and 12 months post-procedure

    Time frame: 6, 12 months post-procedure

    ACPP is terminated when stenosis or thrombus causing abnormal clinical indicators occurs in any part of the AVG after surgery (inflow artery, entire graft, and outflow vein, including central vein). (Definition according to NKF- K/DOQI guidelines), including physical examination abnormalities or dialysis abnormalities. Physical examination abnormalities include: open collateral veins, ipsilateral limb edema, changes in pulse characteristics, abnormal tremors, abnormal murmurs, etc.; Dialysis abnormalities include: increased venous pressure, new puncture difficulties, aspiration of thrombi, inability to reach target dialysis blood flow, prolonged haemostasis time after needle removal for 3 consecutive times, unexplained decrease in dialysis dose Kt/V (>0.2 units), decrease in brachial artery blood flow (brachial artery blood flow <650ml/min or decreased by 20% compared with the previous follow-up visit), etc.

  3. Access Circuit Secondary Patency (ACSP) 6 and 12 months after surgery

    Time frame: 6, 12 months post-procedure

    ACSP terminates when the AVG is abandoned due to various reasons after surgery, during which multiple interventions can be performed to maintain the patency of the entire pathway.

  4. Acute Lumen Gain

    Time frame: During the procedure

    Immediately after dilation, DSA uses two different angles (≥45°) for angiography (a unified x-ray ruler will be provided as the reference object to reduce measurement errors) Calculation formula: minimum lumen diameter of the target lesion immediately after dilation - minimum lumen diameter of the target lesion before procedure.

  5. Technical Success

    Time frame: 0-5 days post-procedure

    Residual stenosis of the target lesion after surgery is ≤30%, and no serious adverse events related to the investigational device occurred during the perioperative period.

  6. Clinical Success

    Time frame: 0-5 days post-procedure

    Complete at least one successful hemodialysis session after surgery

Study contacts

Contact information is provided by the study sponsor or research team.

Pei Wang, MD

CONTACT

[email protected]

+86 13523467291

Sponsors and collaborators

Lead sponsor

DK Medical Technology (Suzhou) Co., Ltd.

Industry

Registry information

Official study title

A Multicentre, Randomized Controlled Clinical Trial of Scoring Balloon Versus High Pressure Balloon in the Treatment of Arteriovenous Graft Stenosis

Acronym: DKTAVG

Important dates

Study start
2024
Primary completion
2026
Study completion
2026
First posted
Jul 16, 2024
Registry last updated
Jan 9, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.