Tryton
DevicePercutaneous coronary intervention of a bifurcation lesion, with a Tryton bifurcation coronary stent for the side branch and a drug-eluting coronary stent for the main branch
Other names: Tryton bifurcation stent system
NCT Number: NCT01174433
To assess the safety and feasibility of the use of the Tryton bifurcation coronary stent system for the treatment of single de novo bifurcation lesions in native coronary arteries.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 1 / Phase 2
Castelfranco Veneto's Hospital, Castelfranco Veneto, Italy
Currently available stents were designed for straight lesions, optimised to provide scaffolding (coverage and radial strength) and ease of deliverability. In straight lesions, these stents have been shown to provide superb acute and long-term results. One lesion subset that continues to challenge the interventionalist is bifurcations lesions. A number of different strategies have been employed with standard stents to address bifurcation lesions each of which have significant limitations. Large contemporary registries characterising current stent usage in bifurcating lesions have demonstrated decreased procedural success with increased rates in restenosis and thrombosis (acute, subacute and delayed). The limitations of currently available stents have led groups to develop stents designed specifically to treat bifurcation lesions. The Tryton Side-Branch Stent Stent TM (Tryton Medical, Inc., Newton, MA, USA) is a balloon expandable cobalt chromium stent, designed specifically to treat bifurcation lesions.
The primary objective of this study is to evaluate the safety and feasibility of the use of the Tryton bifurcation coronary stent system for the treatment of single de novo bifurcation lesions in native coronary arteries with reference vessel diameters (RVD) for the proximal main vessel of 2.5 - 5.0 mm, distal main branch of 2.5 - 5.0 mm, and side branch RVD 2.5 - 3.5 mm.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
General Inclusion Criteria
Angiographic Inclusion Criteria
Exclusion criteria
General Exclusion Criteria
Angiographic Exclusion Criteria
Percutaneous coronary intervention of a bifurcation lesion, with a Tryton bifurcation coronary stent for the side branch and a drug-eluting coronary stent for the main branch
Other names: Tryton bifurcation stent system
Time frame: 30 days (plus or minus 3 days)
A composite of cardiac death, target vessel myocardial infarction (MI) and clinically driven target lesion revascularization (TLR) at 30 days post procedure.
Time frame: 30 days (plus or minus 3 days)
Acute device success, Technical Success, Clinical Procedural Success, Device malfunctions, Ease-of-Use parameters, Main branch and side branch angiographic endpoints, Main branch and side branch IVUS endpoints (Reference Lumen Area; Reference EEM Area; Lesion Lumen Area; Lesion EEM Area; Maximum Atheroma Thickness; Minimum Atheroma Thickness; Lesion Maximum Lumen Diameter; Lesion Minimum Lumen Diameter and derived Measurements; calcium measurement)
Time frame: 24 hours
Total volume of contrast used, in mL
Time frame: 24 hours
Total index PCI procedure time, in minutes
Time frame: 9 months
Target vessel revascularization (TVR) rate, at 9 months
Time frame: 9 months
Target lesion revascularization (TLR) rate, at 9 months
Time frame: 9 months
Major Adverse Cardiac and Cerebrovascular Events (MAC(C)E) rate, at 9 months
University of Padova
Other
Acronym: SAFE-TRY
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02039739
Angioplasty, Transluminal, Percutaneous Coronary, Arterial Occlusive Diseases
Anyang, South Korea
View Trial DetailsNCT01004575
Angioplasty, Transluminal, Percutaneous Coronary, Arterial Occlusive Diseases
Lyon, France
View Trial DetailsNCT07316504
Angioplasty, Transluminal, Percutaneous Coronary, Arterial Occlusive Diseases
Clermont-Ferrand, Auvergne, France
View Trial DetailsNCT07468955
Arterial Occlusive Diseases, Arteriosclerosis
Kütahya, Center, Turkey (Türkiye)
View Trial Details