Safety and Effectiveness Trial of the Ventana Fenestrated Stent Graft System

The purpose of this trial is to determine if the Ventana Fenestrated Stent Graft System is safe and effective for the endovascular repair of juxtarenal or pararenal aortic aneurysms.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of Alabama at Birmingham, Birmingham, Alabama, United States

Loading trial locations.

About this study

Study Objectives The objective of protocol CP-0004 is to study the safety and effectiveness of the Endologix Fenestrated System in the endovascular treatment of patients with juxtarenal and/or pararenal aortic aneurysms.

Study Design This clinical study is a prospective, non-randomized, multicenter study. The first patient enrolled at each site is designated as a 'Roll-In' group patient. Subsequently, enrolled patients are designated as 'Trial' group patients for primary endpoint analysis.

Primary Endpoint The primary safety endpoint is defined as the incidence of Major Adverse Events‡ (MAEs) within 30 days. The primary study effectiveness endpoint is Treatment Success at 1-year. This is defined as procedural technical success and the absence of aneurysm rupture; conversion to open surgical repair; Type I endoleak after 30 days; Type III endoleak; clinically significant migration; aneurysm enlargement; or secondary intervention for resolution of endoleak, limb occlusion, migration, aneurysm sac expansion and/or a device defect.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male or female at least 18 years old;
  • Informed consent understood and signed and patient agrees to all follow-up visits;
  • Have aortic aneurysm with maximum diameter ≥5.5cm, or between 4.5 and 5.5cm and rapidly expanding (>0.5cm in six months), or >50% larger than the normal aortic diameter
  • Anatomically eligible for the Bifurcated System per the FDA-approved indications for use (IFU) and for the Fenestrated Stent Graft System:
  • Adequate iliac/femoral access compatible with the required delivery systems
  • Non-aneurysmal infrarenal aortic neck <15mm in length;
  • Most caudal renal artery to aortoiliac bifurcation length ≥70mm
  • SMA to aortoiliac bifurcation length ≥90mm;
  • Proximal non-aneurysmal aortic neck below the SMA with: diameter 18 to 34 mm; length ≥15 mm; angle ≤60° to the aneurysm sac;
  • Angle ≤60° (clock face) between the SMA and CA
  • Renal arteries both distal to the SMA by ≤35mm, within 30mm of each other axially, with 4 to 8mm lumen diameter, and with clock face angle of 90° to 210° to each other .Common iliac artery distal fixation site with: distal fixation length ≥15 mm; ability to preserve at least one hypogastric artery; diameter ≥10 mm and ≤23 mm; angle ≤90° to the aortic bifurcation.
  • The Endologix Fenestrated Proximal Extension Stent must have the ability to overlap the bifurcated stent graft by at least 3cm.
  • Aortic diameter at the most caudal renal artery of 18 to 36mm

Exclusion criteria

  • Life expectancy <2 years as judged by the investigator;
  • Psychiatric or other condition that may interfere with the study;
  • Participating in the enrollment or 30-day follow-up phase of another clinical study;
  • Known allergy to any device component;
  • Coagulopathy or uncontrolled bleeding disorder;
  • Contraindication to contrast media or anticoagulants;
  • Ruptured, leaking, or mycotic aneurysm;
  • Aortic dissection
  • Serum creatinine (S-Cr) level >2.0 mg/dL;
  • Traumatic vascular injury;
  • Active systemic or localized groin infection;
  • Connective tissue disease (e.g., Marfan's Syndrome);
  • Recent (within prior three months) cerebrovascular accident or myocardial infarction;
  • Prior renal transplant;
  • Length of either renal artery to be stented <13mm;
  • Significant occlusive disease of either renal artery (>70% stenosis);
  • An essential accessory renal artery;
  • Indispensable inferior mesenteric artery;
  • Aneurysmal disease of the descending thoracic aorta;
  • Clinically significant mural thrombus circumferentially in the suprarenal segment;
  • Prior iliac artery stent implanted that may interfere with delivery system introduction;
  • Unsuitable vascular anatomy;
  • Pregnancy (female patient of childbearing potential only)
  • Existing renal stent;
  • Pre-planned need for concomitant procedure (e.g. surgical conduit for vascular access, hypogastric artery embolization/coil, renal artery angioplasty)

Treatment and study plan

Ventana Fenestrated Stent Graft System

Device

The Ventana Fenestrated Stent Graft System consists of the following:

bifurcated stent graft, Ventana fenestrated proximal extension stent graft, and Xpand renal stent grafts

Primary outcomes

  1. Safety- Number of Major Adverse Events at 30 Days

    Time frame: 30 Days

    Major Adverse Events = all cause death; bowel ischemia; myocardial infarction; paraplegia; renal failure; respiratory complications of stroke; blood loss >1000cc

  2. Effectiveness

    Time frame: 1 Year

    • Treatment Success is defined as Procedural technical success and absence of aneurysm rupture, conversion to open repair, Type I endoleak after 30 days, Type III endoleak, clinically significant migration; aneurysm enlargement; or secondary intervention for resolution of endoleak, limb occlusion, migration, aneurysm sac expansion and/or a device defect.
    • Procedural Technical Success is defined as a subject with successful implant.
    • Clinically Significant Device Migration: Core Lab reported aortic stent graft movement >10mm
    • Type I/III/IV Endoleak: Core Lab reported endoleak: between the endograft and the vessel either at the proximal attachment point (Type IA), or at the distal attachment point (Type IB), or between endograft components (Type III) or transgraft (Type IV).
    • Type II Endoleak: Core Lab reported endoleak emanating from a patent collateral vessel (e.g., inferior mesenteric artery, lumbar artery).

Secondary outcomes

  1. Safety- Number of Major Adverse Events > 30 Days to 5 Years

    Time frame: >30 Days to 5 Years

    Major Adverse Events = all cause death; bowel ischemia; myocardial infarction; paraplegia; renal failure; respiratory complications of stroke; blood loss >1000cc

  2. Renal Dysfunction

    Time frame: Discharge to 5 Years

    Renal Dysfunction is calculated at greater than 30% reduction starting at baseline

  3. Endoleaks

    Time frame: 30 Days to 5 Years

    Endoleaks- Type IA, Type IB, Type II, Type IIIA, Type IIIB, Type IV, and Unknown Type

    Type I/III/IV Endoleak: Core Lab reported endoleak: between the endograft and the vessel either at the proximal attachment point (Type IA), or at the distal attachment point (Type IB), or between endograft components (Type III) or transgraft (Type IV).

    Type II Endoleak: Core Lab reported endoleak emanating from a patent collateral vessel (e.g., inferior mesenteric artery, lumbar artery).

  4. Clinical Utility Outcomes

    Time frame: At the time of the procedure

    Clinical Utility Outcomes consist of: fluoroscopy time, Bifurcated device placement time, Renal Artery Cannulation time, F-EVAR time and total procedure time.

  5. Time in ICU

    Time frame: In-Hospital

    Number of days spent in the intensive care unit (ICU)

  6. Time to Hospital Discharge

    Time frame: Hospital Discharge (Post-Procedure)

    Number of days from the index procedure to discharge from the hospital.

  7. Device Patency

    Time frame: 30 Days to 5 Years

    Device patency- Ventana & Bifurcated Occlusion, Left Renal Artery Occlusion, and Right Renal Artery Occlusion

  8. Device Integrity

    Time frame: 30 Days to 5 Years

    Device Integrity- Device Migration, Ventana Stent Fracture, Left Renal Stent Fracture, Right Renal Stent Fracture, and Stent Kinking/ Compression

  9. Aneurysm Sac Morphology

    Time frame: 30 Days to 5 Years

    Aneurysm Sac Morphology- Aneurysm Shape, Aneurysm Enlargement

  10. Aneurysm Sac Diameter

    Time frame: 30 Days to 5 Years

    Aneurysm Sac diameter changes

  11. Clinical Utility Outcomes

    Time frame: At the time of the procedure

    Clinical Utility Outcomes consists of: contrast volume and estimated blood loss.

Sponsors and collaborators

Lead sponsor

Endologix

Industry

Registry information

Official study title

Prospective, Multicenter, Single Arm Safety and Effectiveness Trial of the Endologix Fenestrated Stent Graft System for the Endovascular Repair of Juxtarenal/Pararenal (JAA/PAA) Aneurysms

Important dates

Study start
2013
Primary completion
2017
Study completion
2018
First posted
Dec 14, 2011
Registry last updated
Oct 15, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.