3D Holographic Guidance, Navigation, and Control for Endovascular Aortic Repair

This is an Early Feasibility Study to evaluate the usability, safety and functionality of 3D holographic guidance, navigation, and control (3D-GNC) as an adjunct to and confirmed by fluoroscopic imaging to be used with Cook Zenith Flex AAA Endovascular Graft®.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Cleveland Clinic

Cleveland, Ohio, 44195, United States

About this study

The goal of this clinical study is to evaluate the feasibility of using electromagnetic (EM) guidance and tracking to precisely place a Cook Zenith Flex AAA bifurcated stent graft during EVAR. EM guidance and tracking is enabled using a system consisting of the following: 1) experimental 3D guidance, navigation, and control (3D-GNC) software developed by Centerline Biomedical, Inc., integrated with the company's FDA-cleared Intra-Operative Positioning System (IOPS), 2) FDA-cleared compatible sensorized guidewires added to the Cook Zenith Flex delivery system and 3) 3D visualization on the IOPS mobile cart monitor and 3D holographic visualization overlaid on the patient during the procedure using a head mounted display (HMD), the Microsoft HoloLens 2. Planning and execution of each case will be major steps in demonstrating feasibility of the technology beyond non-clinical and preclinical testing.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The patient meets the instructions for use (IFU) for the 24-28 mm body Cook Zenith Flex AAA bifurcated stent graft.
  • Adequate iliac/femoral access compatible with the required introduction system
  • Non aneurysmal infrarenal aortic segment (neck) proximal to the aneurysm:

i. With a length of at least 15mm ii. With a diameter measured outer wall to outer wall of no greater than 26mm and no less than 20mm iii. With an angle less than 60 degrees relative to the long access of the aneurysm and iv. With an angle less than 45 degrees relative to the axis of the suprarenal aorta c. Iliac artery distal fixation site greater than 10mm in length and 7.5-20mm in diameter (measured outerwall to outerwall).

  • Male/female, aged ≥ 18
  • Patient fulfilling criteria for needing endovascular repair of abdominal aortic aneurysm according to routine clinical practice criteria of the participating center
  • Women of childbearing potential must be non-pregnant, non-lactating, and not planning to become pregnant during the course of the trial; and have a negative urine or serum pregnancy test within 7 days prior to index procedure
  • Provide written informed consent as applicable and defined by site country regulation
  • Stated willingness to comply with all study procedures and availability for the duration of the study

Exclusion criteria

An individual who meets any of the following criteria will be excluded from participation in this study:

  • Contraindications for Cook Zenith Flex Aortic endograft:
  • Patients with known sensitivities or allergies to stainless steel, polyester, solder (tin, silver), polypropylene, or gold
  • Patients with a systemic infection who may be at increased risk of endovascular graft infection
  • Presence of electronic implants, e.g., cardiac pacemaker, automatic implantable cardioverter/defibrillator (AICD) or nerve stimulator
  • Presence of metallic implants above the knee, e.g., artificial hip
  • Patients not willing or able to give informed consent
  • Pregnant women
  • Patients' inability to have a contrasted CT scan
  • Current or planned participation in any other investigational drug or medical device clinical study that has not completed primary endpoint(s) evaluation;
  • Other medical, social, or psychological issues that in the opinion of the investigator preclude the subjects from receiving this treatment, and the procedures and evaluations pre- and posttreatment
  • Anatomy outside of the IFU for a 24-28 mm Cook Zenith Flex AAA bifurcated stent graft

Treatment and study plan

3D Holographic Guidance, Navigation, and Control (3D GN&C)

Device

Using electromagnetic (EM) guidance and tracking to precisely place a Cook Zenith Flex AAA bifurcated stent graft during EVAR. EM guidance and tracking is enabled using a system consisting of:

  • experimental 3D guidance, navigation, and control (3D-GNC) software developed by Centerline Biomedical, Inc., integrated with the company's FDA-cleared Intra-Operative Positioning System (IOPS),
  • FDA-cleared compatible sensorized guidewires added to the Cook Zenith Flex delivery system, and
  • 3D visualization on the IOPS mobile cart monitor and 3D holographic visualization overlaid on the patient during the procedure using a head mounted display (HMD), the Microsoft HoloLens 2.

Primary outcomes

  1. Number of Participants With Successful Implantation of Cook Zenith AAA Endovascular Graft Using the 3D-GN&C Device

    Time frame: By the end of the procedure, average of 2 hours

    Number of Patients with Correct positioning of the endovascular stent graft using the 3D-GN&C device confirmed by fluoroscopic imaging

Secondary outcomes

  1. Delivery System Placement in the Intended Location

    Time frame: At the time of the procedure

    Number of patients with the delivery system located in the intended location confirmed by measuring the distance between the fluoroscopy and digital subtraction angiography less than 6 mms.

Other outcomes

  1. Incidence of Adverse Event (AE)/Serious Adverse Event (SAE) Related to 3D-GN&C Device

    Time frame: Through study completion, an average of 30 days

    Incidence of SAE (serious adverse events) related to 3D-GNC device as well as incidence of non-SAE (non-Serious Adverse Events) related to 3D-GNC device

Sponsors and collaborators

Lead sponsor

The Cleveland Clinic

Other

Collaborators

  • National Heart, Lung, and Blood Institute (NHLBI)

Registry information

Official study title

3D Holographic Guidance, Navigation, and Control (3D GN&C) for Endovascular Aortic Repair (EVAR)

Acronym: 3D-GN&C

Important dates

Study start
2023
Primary completion
2025
Study completion
2025
First posted
Aug 23, 2023
Registry last updated
Apr 24, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.