Minneapolis Heart Institute Foundation
Minneapolis, Minnesota, 55407, United States
NCT Number: NCT05531084
The primary objective of the present study is to evaluate the safety, effectiveness, and clinical outcomes of surgeon-modified fenestrated stent grafts used to treat patients with failed previous infrarenal repairs (failed EVAR) and complex aortic aneurysms (thoracoabdominal, juxtarenal, pararenal, and paravisceral aneurysms).
Trial opening soon.
Get Notified18 year and older
All sexes
Interventional
Not applicable
Minneapolis, Minnesota, 55407, United States
The study is a prospective, non-randomized evaluation of endovascular repair of patients with failed previous infrarenal repairs (failed EVAR) and complex thoracoabdominal/juxtarenal/pararenal/paravisceral aortic aneurysm repair, including those with penetrating ulcers and aneurysms resulting from aortic dissections, who (1) have anatomy that is not suitable for endovascular repair using grafts currently marketed in the United States, (2) are deemed unsafe to wait the required time necessary for commercial endograft manufacturing, and (3) are at high risk for open surgical repair.
Depending on the location of the aneurysm, patients with failed EVAR and complex aortic pathology requiring fenestrated and branched endovascular repair will be treated with physician-modified Cook Zenith devices (Zenith Flex, Zenith Fenestrated stent graft (Zfen), Cook Alpha Thoracic Endovascular Graft, Cook dissection TX2), and their associated commercially approved ancillary components. Whenever possible, the Zenith fenestrated universal bifurcated device will be used for patients requiring repair down to the iliac arteries. The Gore Excluder Endoprosthesis or the Gore Iliac Branch Endoprosthesis (IBE) will be used whenever the Zenith universal bifurcated device is not available. Safety and effectiveness will be assessed acutely (i.e., treatment success and technical success), at 30 days (i.e., the rate of major adverse events (MAE)), at 6 months, at 12 months, and annually to 5 years (i.e., the proportion of treatment group subjects that achieve and maintain treatment success).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
a. Anatomic i. Previous abdominal surgery ii. Previous left-sided thoracotomy (if the proposed open repair would require dissection of the thoracic aorta) iii. Previous aortic surgery b. Physiological high risk For this IDE, physiological risk will be assessed using two systems. First, this study will use the Society for Vascular Surgery (SVS)/American Association for Vascular Surgery (AAVS) medical comorbidity grading system recommended for use by the SVS to describe the severity of medical comorbidities in patients with complex aortic aneurysm disease. However, as the current SVS/AAVS grading system has yet to be validated in prospective studies or in a large cohort of patients treated for aortic disease, the American Association of Anesthesiologists grading system will also be utilized due to its widely adopted use and simplicity although it relies on subjective parameters and lacks specific metrics that affect outcomes.
Medical Inclusion Criteria
SVS/AAVS grading system: low risk (0.12-1% mortality risk), medium risk (1.7-4.9% mortality risk), and high risk (8-20% mortality risk) subjects will be considered for study inclusion though final subject approval will be at the discretion of the treating vascular specialist; prohibitive high risk (31-70% mortality risk) subjects will be excluded.
Anatomical Inclusion Criteria
Exclusion criteria
Depending on the location of the aneurysm, patients with failed EVAR and complex aortic pathology requiring fenestrated and branched endovascular repair will be treated with physician-modified Cook Zenith devices (Zenith Flex, Zenith Fenestrated stent graft (Zfen), Cook Alpha Thoracic Endovascular Graft, Cook dissection TX2), and their associated commercially approved ancillary components.
Other names: Cook Zenith Alpha Thoracic Endovascular Graft (P140016), Cook Zenith Fenestrated AAA Endovascular Graft (P020018 S044), Cook Zenith TX2 Dissection Endovascular Graft (P180001), Cook Zenith Flex AAA Bifurcated Main Body (P020018 S055), Atrium iCAST covered Stent (K050814), Gore Viabahn VBX Balloon Expandable Endoprosthesis (P160021)
Time frame: 5 years
Primary outcome criteria:
Time frame: 5 years
Secondary outcome criteria (as evidenced on follow up imaging and laboratory tests):
Time frame: 5 years
presence of any endoleak requiring intervention
Time frame: 5 years
Time frame: 5 years
Time frame: years
Contact information is provided by the study sponsor or research team.
Jesse Manunga, MD, FSVS, FACS
CONTACT
JoAnne Goldman
CONTACT
Jesse Manunga, MD
Other
Safety and Effectiveness of Surgeon-Modified Fenestrated and Branched Endografts in Treating Subjects With Complex Aortic Aneurysms
Acronym: Assets
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04689139
Acute Aortic Syndrome, Aneurysm
Moscow, Russia
View Trial DetailsNCT07480395
Abdominal Aorta Aneurism, Aneurysm
View Trial DetailsNCT03295682
Thoracoabdominal Aneurysm
Düsseldorf, North Rhine-Westphalia, Germany
View Trial DetailsNCT03074487
Cardiovascular Diseases, Central Nervous System Diseases
Maastricht, Limburg, Netherlands
View Trial Details