Lakehead University
Thunder Bay, Ontario, P7B 5E1, Canada
NCT Number: NCT06584903
Extreme heat events are a significant global threat to health and wellbeing, and result in more morbidity and mortality than all other natural disasters combined. Thus, a key priority is identifying effective and accessible heat resilience solutions to protect individuals from the potentially fatal consequences of heat stress. Within a range of ambient conditions, a fan has been recognized a low-cost heat resilience solution. However, when ambient temperatures exceed skin temperatures (e.g., above 35°C), a fan will incur greater dry heat gain which may be counterbalanced with evaporation of sweat from the skin surface. However, at a critical indoor temperature, the rate of heat gain will exceed the rate of evaporation resulting in net heat gain. The critical indoor temperature has yet to be determined. The purpose of this present study is to identify the indoor temperature at which a fan results in greater cardiovascular and thermal strain relative to still air in young adults using a simulated heat wave scenario of a warming room.
Looking for future studies?
Notify Me19 year–39 year
All sexes
Interventional
Not applicable
Thunder Bay, Ontario, P7B 5E1, Canada
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Following a 45 minute baseline in 37°C seated on a chair, the indoor temperature in the climate-controlled room increased from 37°C to 47°C at ~0.06°C/min (relative humidity ~26%) over 180 minutes.
Time frame: At baseline (e.g. 0 minutes), and every 10 minutes of exposure up to 180 minutes
Measured with an electrocardiogram-gated automated cuff
Time frame: At baseline (e.g. 0 minutes), and every 10 minutes of exposure up to 180 minutes
Time frame: At baseline (e.g. 0 minutes), and every minute for the 180 minute experimental trial
Measured with a 3-lead electrocardiogram
Time frame: At baseline (e.g. 0 minutes), and every minute for the 180 minute experimental trial
Measured at 4 skin locations (chest, arm, thigh, and calf) using wireless iButtons affixed to the skin with surgical tape
Time frame: At baseline (e.g. 0 minutes), and every minute for the 180 minute experimental trial
rectal temperature measured with a pediatric grade thermistor probe
Time frame: At baseline (e.g. 0 minutes), and every minute for the 180 minute experimental trial
Net difference in body mass (pre versus post) using a balance scale placed below the chair of the participant
Time frame: At baseline (e.g. 0 minutes), and every 10 minutes for the 180 minute experimental trial
visual analog scale
Time frame: Assessed at baseline (e.g. 0 minutes), and every 10 minutes for the 180 minute experimental trial
visual analog scale
Lakehead University
Other
Fan Use During Extreme Heat: Safe Thermal Limits
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05727774
Healthy, Heat Exposure
Montpellier, France
View Trial DetailsNCT07032493
Aging, Body Temperature Changes
Ottawa, Ontario, Canada
View Trial DetailsNCT06630832
Behavior, Behavioral Symptoms
Ottawa, Ontario, Canada
View Trial DetailsNCT05838612
Aging, Body Temperature Changes
Ottawa, Ontario, Canada
View Trial Details