NCT Number: NCT01064076

S-ICD® System IDE Clinical Study

This clinical study is designed to evaluate the safety and effectiveness of the subcutaneous implantable defibrillator (S-ICD) System.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

St. Antonius Ziekenhuis, Nieuwegein, Netherlands

Loading trial locations.

About this study

This clinical study is a prospective, non-randomized, multicenter clinical study without a control group conducted in the United States, Europe, and New Zealand.

Patients meeting eligibility criteria for implanting an S-ICD System will be enrolled in this clinical study, implanted with an S-ICD System, and followed prior to hospital discharge, and post-implant at 30 days, 90 days, and 180 days. After the 180-day post-implant follow-up visit, patients will continue to be followed semi-annually until study closure.

Eligible patients enrolled in this clinical study may also participate in the chronic conversion sub-study.

The safety endpoint will be evaluated through the use of a 180-day S-ICD System complication-free rate. The effectiveness endpoint will be evaluated using an induced ventricular fibrillation (VF) conversion efficacy rate. Spontaneous episodes and chronic conversion testing data will be evaluated using descriptive statistics to provide additional data supporting the continued chronic performance of the S-ICD System.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • For patients without an existing transvenous device
  • Patient meets Class I, Class IIa or Class IIb indications/recommendations for ICD implantation per the current published guidelines at the time of enrollment
  • For patients with an existing transvenous device
  • Patient requires replacement or revision of an existing implanted transvenous ICD system
  • Age is ≥ 18 years
  • An appropriate pre-operative ECG per template provided

Exclusion criteria

  • Any condition which precludes the subject's ability to comply with the study requirements, including completion of the study.
  • Females who are pregnant or lactating and pre-menopausal women who are unwilling to use adequate birth control for the duration of the study.
  • Participation in any other investigational study without prior written consent from the study sponsor.
  • Patients with a serious medical condition and life expectancy of less than one year.
  • Patients with documented spontaneous and frequently recurring VT that is reliably terminated with anti-tachycardia pacing, unless the patient is not a candidate for a transvenous ICD system.
  • Patients with existing epicardial patches or subcutaneous electrodes in the left thoracic quadrant.
  • Patients with unipolar pacemakers or implanted devices that revert to unipolar pacing.
  • Patients with severely impaired kidney function as measured by a Cockcroft-Gault Glomerular Filtration Rate (GFR) with an estimated GFR ≤ 29.

Treatment and study plan

S-ICD System

Device

The S-ICD System is an implantable technology that uses a subcutaneous pulse generator and subcutaneous electrode system to treat ventricular tachyarrhythmias. The S-ICD System consists of the SQ-RX pulse generator (Model 1010), the Q-TRAK subcutaneous electrode (Model 3010), the Q-TECH programmer (Model 2020), and Q-GUIDE electrode insertion tools (Models 4010 and 4020).

Other names: SQ-RX Pulse Generator, Q-TRAK Subcutaneous Electrode, Q-GUIDE Electrode Insertion Tools, Q-TECH Programmer

Primary outcomes

  1. Percentage of Participants Free of Type I Complications at 180 Days.

    Time frame: 180 days

    Percentage of Participants Free of Type I Complications at 180 days compared to the performance goal of 79%. Type I complications are those caused by the S-ICD System.

  2. Percentage of Participants Who Pass Induced VF Conversion Test

    Time frame: Implant/Pre-Discharge

    Percentage of participants who pass induced VF conversion test was compared to a performance goal of 88%. Definition of a success was two consecutive successful 65 joule shocks out of four attempts in the same polarity.

Sponsors and collaborators

Lead sponsor

Boston Scientific Corporation

Industry

Registry information

Official study title

S-ICD® System Clinical Investigation

Important dates

Study start
2010
Primary completion
2011
Study completion
2013
First posted
Feb 8, 2010
Registry last updated
Mar 27, 2017