Medical University of Vienna
Vienna, 1090, Austria
NCT Number: NCT01416753
Background: Data generated with the body composition monitor (BCM, Fresenius) show based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood-volume monitored regulation of ultrafiltration and dialysate conductivity (UCR) and/or regulation of ultrafiltration and temperature (UTR) will decrease complications when ultrafiltration volumes are systematically increased in fluid overloaded hemodialysis patients.
Methods/Design: BCM-measurements yield results on fluid overload (in liters), relative to extracellular water (ECW). In this prospective, multicenter, triple-arm, parallel group, cross-over, randomized, controlled clinical trial, we use BCM-measurements, routinely introduced in our 3 maintenance hemodialysis centers shortly prior to the start of the study, to recruit 60 hemodialysis patients with fluid overload (defined as ≥15% ECW). Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, 'final' dry weight is set as -7% ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase). In case of intradialytic complications, dry weight reduction is decreased, according to a pre-specified algorithm. A comparison of intra- and postdialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study phase (secondary outcome parameters).
Discussion: Patients are not requested to revert to their initial degree of fluid overload after each study phase, Therefore, the cross-over design of the present study merely serves the purpose of secondary end-point evaluation, for example to determine patient choice of treatment modality. Previous studies on blood volume monitoring have yielded inconsistent results. Since we include only patients with BCM-determined fluid overload, we expect a benefit for all study participants, due to strict fluid management which decreases the mortality risk of hemodialysis patients.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Vienna, 1090, Austria
Hypothesis In comparison to conventional hemodialysis, regulation of ultrafiltration and dialysate conductivity (UCR) and/or regulation of ultrafiltration and temperature (UTR) will decrease intra- and postdialytic complications when ultrafiltration volumes are systematically increased in fluid overloaded hemodialysis patients.
Objectives and Outcome Measures The primary objective is to demonstrate superiority of ultrafiltration and dialysate conductivity regulation (UCR) and/or ultrafiltration and temperature regulation (UTR) over conventional hemodialysis, in preventing intra- and postdialytic complications, when fluid overloaded hemodialysis patients receive systematic fluid reduction, to reach a final dry weight of 7% ECW postdialysis. The primary outcome measure is the total number of hemodialysis sessions per patient that were accompanied, intra- or postdialytically, by at least one symptom most likely related to fluid withdrawal (as specified in Table 1), divided by the number of hemodialysis sessions at risk (as by study protocol: 12 sessions per patient in study phase 1). Both groups, UCR and UTR, will be compared against the conventional hemodialysis group, and afterwards against one another, using the two-sided Student's t-test.
The secondary objectives are:
when fluid overloaded hemodialysis patients receive systematic fluid reduction, to reach a final dry weight of -7% ECW postdialysis. The secondary outcome measure for objective [a] is the total number of hemodialysis sessions per patient which were accompanied by the respective symptom most likely related to fluid withdrawal (1 to 6), divided by the number of hemodialysis sessions at risk (as by study protocol: 12 sessions per patient in study phase 1). Both groups, UCR and UTR, will be compared against the conventional hemodialysis group, and afterwards against one another, using the two-sided Student's t-test.
Example: If a patient has a postdialysis body weight of 65 kg at time zero (the last hemodialysis session before the first dry weight reduction), and reaches a postdialysis body weight of 62 kg at the end of the first study phase, his difference in body weight will be 65 kg - 62 kg =3 kg. Relative to this patient's postdialysis body weight at time zero, weight reduction from beginning to end of study phase 1 will be 3/65*100=4.61%.
The relative weight reduction in both groups, UCR and UTR, will be compared against the conventional hemodialysis group, and afterwards against one another, using the two-sided Student's t-test.
The amount of sodium removed during hemodialysis is a function of the ultrafiltration volume, the effective diffusion gradient for sodium, and diffusive sodium clearance. The effective diffusion gradient depends on the plasma water - dialysate sodium (DNa) difference, and the Gibbs-Donnan coefficient, the latter being a function of the plasma protein concentration but also being influenced by other ions in the dialysate. The assumption that sodium removal by ultrafiltration is equal to the plasma water sodium concentration, multiplied by the ultrafiltration volume, is a simplification. Electrolyte balances may also be influenced by the membrane charge. Therefore, the amount of sodium transferred will be measured on the dialysate side. Sodium transfer will be calculated from the difference between the mean sodium concentration in partially collected, used dialysate and the fresh DNa concentration, multiplied by the total amount of dialysate used. Results will be compared to a two pool sodium model and parameters of the model will be adjusted using the measured transfer data.
The above described method is not applicable to the UCR group because the sodium concentration of fresh dialysate is not kept constant during treatment. In order to establish the model, we will measure at least 10 patients during 3 hemodialysis sessions, and due to the formerly stated, we can only use the dialysate from patients in the conventional hemodialysis group and in the UTR group.
However, after having established this model, sodium transfer for all patients - conventional, UTR, and UCR - can be calculated using this very model.
The amount of sodium transferred to or withdrawn from the patient will be calculated for each patient, according to the model established in the way stated here above. The secondary outcome measure for objective [d], e.g. the sodium transferred in both groups, UCR and UTR, will be compared against the conventional hemodialysis group, and afterwards against one another, using the two-sided Student's t-test.
We have recently discovered that various proteins, including those mentioned here above, may render HDL dysfunctional, in hemodialysis patients. Especially with surfactant, we suspect an association with fluid overload. Moreover, plasma tryptophan, plasma choline, and plasma trimethylanine-N-oxide are markers of end stage renal disease. Since one or several of these proteins or molecules might serve as novel biomarkers, we would like to use the context of the present trial to establish diagnostic assays and analyze potential changes in the serum concentration of these proteins, before and after fluid removal.
Endotoxin, found in the cell membranes of gram-negative bacteria, is a biomarker representing the gut flora. Endotoxin has been shown to be associated with inflammation, nutritional status and even mortality in hemodialysis patients. An incremental rise in endotoxin levels has been shown along with the progression of chronic kidney disease, and especially initiation of hemodialysis. It has been suggested that hemodialysis patients might have high endotoxin levels in the blood due to repeated bacterial translocation from the gut during hemodialysis, secondary to intradialytic changes in blood pressure and/or tissue perfusion. An association with chronic fluid overload has not yet been established, but might be suspected, as a consequence of higher ultrafiltration rates and thus decreased intradialytic stability. Here we will measure endotoxin levels with an amebocyte limulus assay in all study patients, at time zero and at the end of study phase 1.
The secondary outcome measure for objective [f], for example HDL-associated serum amyloid A in both groups, UCR and UTR, at time zero and at the end of study phase 1, will be compared against the conventional hemodialysis group, and afterwards against one another, using the two-sided Student's t-test. The individual change in these parameters, from time zero to the end of study phase 1, will be compared likewise. The results of this secondary endpoint analysis will be published separately from the clinical results of the present study.
Superiority definition For all objectives listed, superiority will be assumed if a statistically significant difference between one group versus another group can be determined. With regards to the primary endpoint, according to our sample size calculation (see below), this study is suited to detect a minimal difference of 10% between groups.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
BVM-based regulation of ultrafiltration and conductivity
BVM-based regulation of ultrafiltration; regulation of temperature
Time frame: 4 weeks for one study phase
The study sample will consist of 60 patients with ECV ≥15%, by BCM-measurement. For the primary endpoint analysis, we will assess the differences in intradialytic complications between the three study groups, only during the first study phase. The UCR and UTR groups will be tested against the conventional HD control group, and afterwards against one another.
Time frame: (as above)
(as above)
Marcus Saemann
Other
A Randomized Controlled Clinical Trial Comparing, in Fluid-Overloaded Hemodialysis Patients, Three Strategies of Fluid Removal: Regulation of Ultrafiltration and Dialysate Conductivity, Regulation of Ultrafiltration and Temperature, and Standard Hemodialysis
Acronym: BVM-Reg
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06798272
Chemically-Induced Disorders, Female Urogenital Diseases
Lodz, Poland
View Trial DetailsNCT06003205
Chemically-Induced Disorders, Edema
Oslo, Norway
View Trial DetailsNCT05288101
Chemically-Induced Disorders, Chronic Kidney Disease Requiring Chronic Dialysis
Querétaro, Mexico
View Trial DetailsNCT02020642
Apnea, Chemically-Induced Disorders
Lausanne, Canton of Vaud, Switzerland
View Trial Details