Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06387745

Referral of Patients to Hepatology With Hepatoscope

Patients identified as being at risk of liver fibrosis because of a positive Fibrosis-4 (FIB-4) test in the primary care setting will be offered be enrolled in the trial and to undergo an Hepatoscope exam (external non-invasive ultrasound imaging exam) to screen for liver fibrosis (with stiffness measurements) and/or steatosis (with ultrasound parameters related to fatty liver). All patients presenting with a liver stiffness value of at least 6.5 kilopascal (kPa) will be referred to the tertiary hepatology consultations for further assessment. Hepatoscope measurements will be compared to the standard of care for these patients, as defined at the tertiary hepatology center.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Universitair Ziekenhuis Antwerpen

Edegem, Antwerp, 2650, Belgium

Location status: Recruiting

Location contact

Luisa Vonghia, MD - PhD

CONTACT

[email protected]

003238213323

About this study

Chronic liver diseases (CLD) remain asymptomatic for a long time, until they become decompensated (cirrhosis) or lead to liver cancer. CLD all have a very similar natural history: over several years, or even tens of years, liver fibrosis develops progressively, which leads to cirrhosis and the related risks of complications of cirrhosis, including portal hypertension, liver failure, of even liver cancer.

In the absence of complications, liver fibrosis and cirrhosis remain completely symptomatic. For this reason, several methods for the non-invasive assessment of liver fibrosis have been developed over the last 20 years, with the objective to screen for liver fibrosis in it early stage so as to manage the patient and potentially prevent to development of complications. There are 2 groups of such noninvasive methods: blood-based tests and methods that measure the liver stiffness, which is directly correlated to liver fibrosis severity.

There are simple blood tests such as the FIB-4 and others can be more complex like FibroTest.

The FIB-4 test, which takes into account 4 parameters easily available (age, platelets, and 2 liver enzymes, AST and ALT), is very useful in the general population because of its high negative predictive value. However, it is mainly used for the diagnosis of liver fibrosis in the context of chronic viral hepatitis.

The measurement of liver stiffness is currently available on a hepatology-dedicated device, the FibroScan, or on high-end ultrasound imaging systems that are available in radiology centers. This measurement of liver stiffness has demonstrated excellent performances for the diagnosis of cirrhosis and a good performance for the assessment of liver fibrosis severity at earlier stages. However, in clinical practice, this method is not widely available nor accessible (cost of equipment of limited to radiology centers).

For the diagnosis of liver steatosis (excess of fat accumulation in the liver), which can also lead to liver fibrosis, cirrhosis and its complications, the Gold Standard exam that can quantify the extent of fat in the liver is Magnetic Resonance Imaging derived Proton Density Fat Fraction (MRI PDFF), but its use in routine is extremely limited due to the lack of MRI equipment, their cost, and the cost of MRI exams. Liver steatosis can be assessed with ultrasound imaging systems (in radiology) and also with FibroScan, although the interpretation of exam results remains variable.

In primary care, in diabetology-endocrinology and in the hepatology practice, it is now known that the screening of chronic liver diseases at their early stages is of paramount importance for a proper management of patients. New simple, available and affordable tools are urgently needed to cover the territory and assess patients at risk where they are, at the point of care, during consultations.

This clinical trial will assess the performance of an ultra-portable, point-of-care ultrasound device for the assessment of liver fibrosis and steatosis in the primary care setting, to optimize referral of patients to the tertiary hepatology consultation for further specialist investigation.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with any of the following
  • Elevated liver enzymes (AST, ALT, Gamma-GT, AP)
  • Type 2 diabetes
  • Elements of metabolic syndrome
  • Patients who consent in written to participate in the Clinical Investigation after being orally informed on the objectives and methods of the Clinical Investigation

Exclusion criteria

  • Patients with active implants such as pacemakers, defibrillators, pumps, etc.
  • Patients presenting wounds at the location where the Hepatoscope probe shall be placed on patients' skin,
  • Pregnant and breastfeeding women,
  • People deprived of their freedom rights.

Treatment and study plan

Hepatoscope

Device

The Hepatoscope is a non-invasive external ultrasound imaging device, intended for general purpose pulse echo ultrasound imaging, and soft tissue elasticity imaging of the human body. In addition, the Hepatoscope provides measurements of shear wave speed and tissue stiffness, ultrasound beam attenuation and estimates of speed of sound, in internal structures of the body.

Primary outcomes

  1. Positive Predictive Value for significant fibrosis

    Time frame: at study completion: 12 months

    Estimation of Positive Predictive Value in percentage with 95% confidence interval for estimation of significant fibrosis.

Secondary outcomes

  1. Correlation of stiffness measurements

    Time frame: at study completion: 12 months

    Liver stiffness measurements performed with the device subject of the research and competitor device will be compared by analysis of correlation. The analysis outcome will be the R² coefficient and its p value.

  2. Concordance of stiffness measurements

    Time frame: at study completion: 12 months

    Liver stiffness measurements performed with the device subject of the research and competitor device will be compared by analysis of concordance. The analysis outcome will be the Concordance Correlation Coefficients (CCC) and 95% confidence intervals.

  3. Diagnostic performance of liver stiffness measurements

    Time frame: at study completion: 12 months

    Area under the receiver operating characteristic (ROC) curve will be used an a general assessment of diagnostic performance against dichotomized population according to referral outcome. Diagnostic estimators in the studied population will be derived from the ROC analysis: sensitivity, specificity, positive and negative predictive values.

Sponsors and collaborators

Lead sponsor

University Hospital, Antwerp

Other

Collaborators

  • E-Scopics

Registry information

Official study title

Use of Ultrasound Tools to Refer Patients at Risk of Chronic Liver Disease to the Hepatology Consultation (US-REFERRAL)

Acronym: US-REFERRAL

Important dates

Study start
2025
Primary completion
2026
Study completion
2026
First posted
Apr 29, 2024
Registry last updated
May 8, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.