ACURATE neo2
DeviceThe ACURATE neo2 valve will be implanted using a two-step mechanism during transfemoral transcatheter aortic valve implantation (TAVI). Balloon predilatation will be recommended in the ACURATE neo 2 valve group.
NCT Number: NCT05036018
Open-label, 2 x 2 factorial, prospective, randomized, national, multicenter study to compare latest-generation self-expanding valves and a minimalist approach versus standard of care in transcatheter aortic valve implantation.
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Interventional
Not applicable
Zentralklinik Bad Berka, Bad Berka, Germany
The purpose of the DOUBEL-CHOICE study is to demonstrate non-inferiority of a latest-generation self-expanding valve (SEV) (ACURATE neo2, Boston Scientific, Marlborough, MA, USA) in comparison to another latest-generation SEV (Evolut Pro, Pro+ and FX, Medtronic Inc., Minneapolis, MN, USA) and of a minimalist approach vs. standard of care with respect to safety and efficacy in patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The ACURATE neo2 valve will be implanted using a two-step mechanism during transfemoral transcatheter aortic valve implantation (TAVI). Balloon predilatation will be recommended in the ACURATE neo 2 valve group.
Isolated local anesthesia. Central venous lines, additional arterial lines for blood pressure monitoring, and urinary catheters will be avoided. Insertion of temporary pacemakers is optional and should be avoided whenever possible, and peri-procedural pacing can then be performed on the left ventricular wire. Patients will be directly transferred to the cardiology ward after the procedure, which can be postponed in case of complications.
The Evolut Pro, Pro+ or FX valve is positioned in a controlled manner either without pacing or under 'slow-rapid' pacing with allowance for limited repositioning and is anchored to the annulus and ascending aorta.
Sedation should be titrated to a Richmond Agitation Sedation Scale (RASS) of 0 to -2 according to local standard of care.The use of EEG monitoring (i.e. BIS, Sedline) can be applied. Continuous CO2-monitoring via face mask should be established during sedation. All patients will receive supplemental oxygen by face mask to maintain an oxygen saturation of approximately 95%. The use of central venous catheters, additional arterial lines for blood pressure monitoring, and urinary catheters can be implemented according to local institutional standards.
Time frame: Day 30
Time frame: Day 30
Leipzig Heart Science gGmbH
Other
Acronym: DOUBLE-CHOICE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07477002
Aortic Valve Disease, Aortic Valve Stenosis
Vienna, State of Vienna, Austria
View Trial DetailsNCT04722250
Aortic Valve Disease, Aortic Valve Replacement
La Jolla, California, United States
View Trial DetailsNCT03112980
Aortic Valve Disease, Aortic Valve Stenosis
Hamburg, Free and Hanseatic City of Hamburg, Germany
View Trial DetailsNCT02701283
Aortic Valve Disease, Aortic Valve Stenosis
Phoenix, Arizona, United States
View Trial Details