IOL implantation experimental (Isopure 1.2.3.)
DeviceImplantation of trifocal IOL POD F GF consisting of light distribution order: far > intermediate > near
NCT Number: NCT04249492
Multicenter, prospective, randomised, controlled, single-blind post-market clinical follow-up (PMCF) study to compare the clinical outcomes of an enhanced depth of focus (EDOF) IOL with the outcomes obtained with a monofocal lens. Implantation of the IOLs is bilaterally.
Looking for future studies?
Notify Me45 year and older
All sexes
Interventional
Not applicable
Hanusch Krankenhaus, Vienna, Austria
This is a multicenter, prospective, randomised, controlled, single-blind post-market clinical follow-up (PMCF) study whereby patients undergoing routine cataract surgery will have bilateral implantation of Enhanced Depth of Focus intraocular lenses (Isopure 1.2.3.) or monofocal lenses (Micropure 1.2.3.). The patients will be randomized in a 1:1 ratio to receive the study or control lenses. Both IOLs, investigational device and control device, are CE approved and commercially available in the countries this clinical investigation is being carried out. The investigational device and all study products, including the devices used for the study examinations, will be used within the intended use specifications from the manufacturer. In addition, no invasive or other burdening examinations will occur for the patient.
The study will be carried out in up to five clinical centers in Europe and Asia.
The device under investigation (Isopure 1.2.3.) is a hydrophobic, glistening-free, acrylic EDOF intraocular lens (IOL) manufactured by the sponsor of this study, PhysIOL sa/nv. The control lens is the parent IOL, belonging to the same IOL family of this manufacturer. It is a hydrophobic, glistening-free, acrylic monofocal IOL (Micropure 1.2.3.). The IOLs will be implanted as part of the routine cataract surgery on patients suffering from cataract development.
Subjects participating in the trial will attend a total of maximum 11 study visits (1 preoperative, 1 or 2 operative and up to 8 postoperative) over a period of 12 months. If local requirements allow, preoperative and operative visit can be done on the same day. Subjects would have the option for unscheduled visits if required medically.
Primary endpoint data will be collected at the 120-180 days follow up visit. Secondary endpoint data will be collected at the 330-420 days follow up visit. Data interim analyses will be done after the last patient finished the 120-180 days postoperative examination to support the study publication plan.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Implantation of trifocal IOL POD F GF consisting of light distribution order: far > intermediate > near
Implantation of trifocal IOL POD F GF consisting of light distribution order: far > near > intermediate
Time frame: 6 months (120-180 days) postoperative
No statistically significant difference between the two study groups on monocular CDVA at 4-6 months follow up visit. A significance level of 0.05 or lower (p < 0.05) will be considered statistically significant. CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018.
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The manifested refraction is measured by means of a phoropter. The data contains values for sphere, cylinder and axis of cylinder according to ISO 11979-7:2018. This data will also be used to calculate the manifested refractive spherical equivalent (MRSE)
Time frame: Preoperative, 1 day (1-2 days) postoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
monocular UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Monocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative
Monocular CDVA using low contrast (10%) optotypes is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. This test is performed using a low-contrast acuity chart with 10% contrast (using the Weber definition: [background - optotype]/background).
Time frame: 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Monocular UIVA@80cm is measured with ETDRS charts placed in 80cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular UIVA@80cm is measured with ETDRS charts placed in 80cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Monocular DCIVA@80cm is measured with ETDRS charts placed in 80cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular DCIVA@80cm is measured with ETDRS charts placed in 80cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative
Monocular DCIVA@80cm using low contrast (10%) optotypes is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. This test is performed using a low-contrast acuity chart with 10% contrast (using the Weber definition: [background - optotype]/background).
Time frame: 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Monocular UIVA@66cm is measured with ETDRS charts placed in 66cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular UIVA@66cm is measured with ETDRS charts placed in 66cm distance. The examination is done without corrective glasses and according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Monocular DCIVA@66cm is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions.
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular DCIVA@66cm is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative
Monocular DCIVA@80cm using low contrast (10%) optotypes is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. This test is performed using a low-contrast acuity chart with 10% contrast (using the Weber definition: [background - optotype]/background).
Time frame: 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
Binocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions.
Time frame: 1 month (30-60 days) postoperative
To assess the visual acuity for different distances, defocus curves under photopic light conditions are measured. This test is performed with best distance corrected refraction and spherical additions ranging from -2.5 D to +1.5 D in 0.5 D steps. In addition the following vergence values are measured: -0.25 D and +0.25 D. This examination is performed monocularly.
Time frame: 6 months (120-180 days) postoperative
To assess the visual acuity for different distances, defocus curves under photopic light conditions are measured. This test is performed with best distance corrected refraction and spherical additions ranging from -2.5 D to +1.5 D in 0.5 D steps. In addition the following vergence values are measured: -0.25 D and +0.25 D. This examination is performed binocularly.
Time frame: 6 months (120-180 days) postoperative
Contrast Sensitivity under photopic light conditions using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time frame: 6 months (120-180 days) postoperative
Contrast Sensitivity under mesopic light conditions using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time frame: 6 months (120-180 days) postoperative
Contrast Sensitivity under mesopic light conditions with a glare source using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time frame: preoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
A Halo and Glare simulator software (Eyeland Design Network GmbH, Germany) will be used to assess the subjective perception of photic phenomena. The patients will be asked to adjust the halo and glare level in a simulated image to the amount they perceive such photic phenomena. This test is performed pre- and postoperatively. The preoperative outcomes deal as a baseline measurement.
Time frame: preoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
To assess the subjective perception of disturbances by photic phenomena, the validated and verified Quality of Vision (QoV) questionnaire will be used.
This questionnaire is a linear-scaled 30-item instrument and is designed with 10 symptoms rated in each of three scales (frequency, severity, and bothersome).
The QoV Questionnaire provides a QoV score in terms of symptom frequency, severity, and bothersome [McAlinden et al, 2010].
Time frame: preoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
To assess if difficulties in daily life occur due to impaired sight. This questionnaire is 9-item Rasch-scaled instrument to assess subjective perception of visual impairment after surgery [Lundström et al, 2009].
Time frame: preoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The PRSIQ is a patient-reported measure assessing spectacle independence following cataract surgery. The analyses conducted provide evidence for the use of the PRSIQ total score as a measure of spectacle independence [Morlock et al, 2017].
Time frame: preoperative, 6 months (120-180 days) postoperative
Aberrometry outcomes are measured with a standard aberrometer. The following values will be evaluated in this study: Spherical aberrations, high order aberrations, lens tilt.
Time frame: preoperative, 6 months (120-180 days) postoperative
Photopic pupil diameters are measured with a precision of at least +/-0.5 mm. For the photopic pupil diameters, eye illumination should be identical to that used for photopic contrast sensitivity testing. It is required that pupil measurements be made with an infrared pupillometer / CCD camera. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 10 minutes).
The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: preoperative, 6 months (120-180 days) postoperative
Mesopic pupil diameters are measured with a precision of at least +/-0.5 mm. For the mesopic pupil diameters, eye illumination should be identical to that used for mesopic contrast sensitivity testing. It is required that pupil measurements be made with an infrared pupillometer / CCD camera. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 10 minutes).
The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: preoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Time frame: Preoperative, 1 day (1-2 days) postoperative, 1 week (7-14 days) postoperative, 1 month (30-60 days) postoperative, 6 months (120-180 days) postoperative, 12 months (330-420 days) postoperative
The IOP will be measured with non-contact tonometer as part of the routine follow up examinations. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Preoperative
Keratometric measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Operative (day of surgery)
The parameter of the implanted IOL must be recorded as well as the target refraction given by the IOL calculator. This parameter is needed to calculate the accuracy of achieving the target refraction. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time frame: Preoperative, 1 month (30-60 days) postoperative
An OCT (optical coherence tomography) image will be taken at the preoperative visit to identify AMD suspicious eyes that need to be excluded from this study. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Beaver-Visitec International, Inc.
Industry
Multicentric Post-Market Clinical Follow-up (PMCF) Investigation to Determine Safety and Efficacy of a Hydrophobic EDOF Intraocular Lens (IOL) in Comparison to a Monofocal IOL
Acronym: PHY2001
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06399211
Aphakia, Aphakia, Postcataract
View Trial DetailsNCT05875922
Cataract, Eye Diseases
Visp, Switzerland
View Trial DetailsNCT04465344
Cataract, Eye Diseases
Ostrava, Czechia
View Trial DetailsNCT04176965
Aphakia, Aphakia, Postcataract
Northridge, California, United States
View Trial Details