University of Minnesota
Minneapolis, Minnesota, 55455, United States
NCT Number: NCT02529748
Dermal transfer efficiency has been defined as the amount of material that moves from one surface to another following contact. The investigators propose to measure dermal transfer efficiency for the following pathways: (1) object to skin, (2) skin to skin, (3) skin to mouth, (4) clothing to skin, (5) gloves to skin, and (6) air to skin. First, the quantitative dermal transfer will be measured for the two selected test substances (lead, Tinopal) for each of these six pathways. The relative quantities of dermal transfer will also then be compared between the different transfer pathways (e.g., is skin to skin transfer greater or less than clothing to skin transfer?). And second, the pattern of transfer will be characterized semi-quantitatively (e.g., does dermal transfer occur consistently and evenly to the skin from different reservoirs?).
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Minneapolis, Minnesota, 55455, United States
Each of the six transfer pathways will be tested and measured in a controlled, ventilated study chamber at the University of Minnesota's School of Public Health Industrial Hygiene Laboratory. To test each pathway, human volunteers will perform repeated contact activities using an identical protocol (e.g., identical number of contacts, type of material contacted, measured pressure of contact, measured time of contact, measured temperature and humidity) so that inter- and intra-individual variability can be characterized.
The qualitative and quantitative sampling methods that will be used have been developed, tested, and published by researchers from the National Institute for Occupational Safety and Health (NIOSH) and other institutions such as ASTM. Specifically, quantitative transfer efficiencies will be measured using accepted wipe sampling protocols taken from several papers in the peer-reviewed literature. Semi-quantitative transfer patterns will be measured using fluorescent tracer intensity techniques that have also been presented in the peer-reviewed literature. The skin surface wipe samples will be sent to an accredited American Industrial Hygiene Association (AIHA) laboratory for analysis.
These sampling results will allow the investigators to report the measured quantitative dermal transfer efficiencies of elemental metallic lead and Tinopal for each pathway in mass per square surface area of skin, and also calculate the relative transfer efficiencies in terms of percent transferred versus originally loaded. Fluorescent tracer maps will allow the investigators to demonstrate the patterns of transfer for each pathway using intensity of the tracer following transfer. Following this analysis, the investigators will then use the data to better inform the relative importance of the pathways in the conceptual model with respect to dermal exposure assessment and modeling efforts. These results are very important for improving the quality of workplace dermal exposure assessments and techniques. The current approaches are not well validated, and it is unknown if the results of existing dermal exposure models are accurate. It is expected that the results of this study will help to improve the protection of workers from certain dermal exposure hazards in the workplace by providing better inputs to the existing dermal exposure models, since it is not possible to collect exposure samples for each job task in the workplace.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Skin wipe samples will be collected to quantify the amount of the test substances transferred to and from the surface of the participants' skin.
Other names: No other names
Consumer product fishing tackle made of elemental lead will be handled by the participants.
Other names: No other names
Tinopal, a fluorescent tracer, will be handled by the participants.
Other names: No other names
Time frame: Surface samples will be collected within an hour of contact or application
Participants will handle or touch the approved test substances or an intermediate transfer material such as a solid surface or clothing. Surface skin wipe sampling will then be conducted to measure the amount of material that has been transferred to or from the skin surface.
University of Minnesota
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05760001
Behavior, Behavioral Symptoms
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT04481152
Disease Attributes, Disease Susceptibility
Paris, France
View Trial DetailsNCT05130632
Environmental Exposure
Guatemala City, Departamento de Guatemala, Guatemala
View Trial DetailsNCT07461857
Environmental Exposure
Berkeley, California, United States
View Trial Details