ALEXANDRE joosten
Villejuif, 94800, France
NCT Number: NCT05131516
The decision to give fluids or not should not be taken lightly. Indeed, excessive or insufficient fluid administration is associated with increased morbidity and mortality. Prediction of fluid responsiveness relies on the use of a hemodynamic variable to determine how likely a patient is going to respond to a fluid bolus with a significant increase in their cardiac output or stroke volume. Depending on the response to fluids, patients are either responders or non-responders.
Today, we have many techniques to predict fluid responsiveness. However, almost all require the use of an advanced hemodynamic monitoring device.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Observational
Villejuif, 94800, France
Predicting fluid responsiveness is important in the operating room in order to avoid unnecessary fluid administration. Over the last 15 years, a number of dynamic tests have been developed which are based on the principle of inducing short-term changes in cardiac preload, using heart-lung interactions, the passive leg raise or by the infusion of small volumes of fluid, and to observe the resulting effect on cardiac output or stroke volume. Pulse pressure and stroke volume variations were first developed, but they are reliable only under strict conditions. The variations in vena caval diameters share many limitations of pulse pressure variations. The passive leg-raising test is now supported by solid evidence and is more frequently used but not practical in the operating room. More recently, the end-expiratory occlusion test has also been described, which is easily performed in ventilated patients. Unlike the traditional fluid challenge, these dynamic tests do not lead to fluid overload. The dynamic tests require the insertion of an arterial catheter linked to an advanced cardiac output monitoring device which is costly and not applicable in lower risk patients without an arterial line.
In the operating room, it is recommended to use alveolar recruitment maneuvers, consisting in the transient administration of higher pressure levels, allowing to re-ventilate certain pulmonary territories by re-expanding alveoli that would have collapsed under mechanical ventilation. In daily practice, it is generally accepted that a patient presenting a significant fall in stroke volume or mean arterial pressure during an alveolar recruitment maneuver is preload dependent, but the scientific evidence in the literature remains insufficient to date. A previous study has also demonstrated the ability to predict fluid responsiveness via analysis of central venous pressure during a recruitment maneuver. By extrapolation, we would like to evaluate the capacity of peripheral venous pressure to predict this fluid responsiveness.
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
alveolar recruitment maneuver (30 mmHg for 30 seconds)
Time frame: during surgery
we will induce, before skin incision, an alveolar recrutment maneuver (standard of care) and observe variations of peripheral venous pressure, then, it will be followed by a volume expansion of 4ml/kg over 5 minutes
Erasme University Hospital
Other
Ability of Peripheral Venous Pressure Variation to Predict Fluid Responsiveness During an Alveolar Recruitment Maneuver in Patients Undergoing Non Cardiac Surgery
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04186416
Fluid Responsiveness, Hemorrhage
Paris, France
View Trial DetailsNCT07245485
Corrected Carotid Flow Time, Fluid Responsiveness
Ankara, Çankaya, Turkey (Türkiye)
View Trial DetailsNCT06188039
Fluid Responsiveness, Surgery
Opole, Poland
View Trial DetailsNCT04914455
Cardiovascular Diseases, Cardiovascular Surgery
Lille, NORD, France
View Trial Details