Robotic anastomosis (Symani surgical system and RoboticScope)
DeviceRobot-assisted microvascular anastomosis on 1.0-mm-diameter silicone vessels using the Symani surgical system and RoboticScope
NCT Number: NCT06146023
The goal of this preclinical trial is to learn about the benefits and limitations of novel robotic devices for microsurgery, based on different levels of microsurgical experience. The main questions it aims to answer are:
Is robot-assisted microsurgery faster, better and more ergonomic than conventional microsurgery in a preclinical standardized setting?
Participants will perform microvascular anastomoses on 1.0-mm-diameter artificial silicone vessels using a conventional manual approach versus a novel robot-assisted approach. Researchers will compare the performance of novices, advanced participants and experts to evaluate the role of microsurgical experience when learning the new technique.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
University Hospital Muenster, Münster, Germany
Recent advancements in the development of robotic devices increasingly draw the attention towards the concept of robotic microsurgery, as several systems tailored to open microsurgery are being introduced. This study describes the combined application of a novel microsurgical robot, the Symani, with a novel robotic microscope, the RoboticScope, for the performance of microvascular anastomoses in a two-center preclinical trial.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Robot-assisted microvascular anastomosis on 1.0-mm-diameter silicone vessels using the Symani surgical system and RoboticScope
Conventional microvascular anastomosis on 1.0-mm-diameter silicone vessels using conventional microsurgical instruments and conventional surgical microscope
Time frame: Duration of anastomosis
Time to perform anastomosis in minutes and seconds.
Time frame: Evaluated right after completion of each anastomosis
Anastomosis lapse index (ALI) to evaluate the quality of each stitch. Score indicates absolute number of errors per anastomosis. Low values indicate better results.
Time frame: Duration of anastomosis
Structured assessment of microsurgery skills (SAMS) to evaluate microsurgical skill acquisition. Score includes 8 items evaluated from 1 (minimum) to 5 (maximum). High values indicate better results.
Time frame: Evaluated right after completion of each anastomosis
Satisfaction with anastomosis und robotic performance (Questionnaire). Evaluation of anastomosis and robotic devices from 1 (minimum) to 10 (maximum). High values indicate better results.
Time frame: Evaluated right after completion of each anastomosis
Rapid entire body assessment (REBA) to evaluate surgical ergonomics. Numeric score, low values indicate better results.
University Hospital Muenster
Other
Preclinical Performance of The Combined Application of Two Robotic Systems in Microsurgery
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06629662
Robotic Surgery
Naples, Italy
View Trial DetailsNCT07467135
Robotic Surgery
Ankara, Turkey (Türkiye)
View Trial DetailsNCT05517551
Low Flow Anesthesia, Normal Flow Anesthesia
Ankara, Turkey (Türkiye)
View Trial DetailsNCT07185607
Colorectal Surgery, Erector Spinae Plane Block
Istanbul, Turkey (Türkiye)
View Trial Details