Skip to main content
OpenTrials
Completed

NCT Number: NCT06700733

PEEK Vs Titanium for All-on-4 Prosthesis

This crossover clinical study will examine the impact of the framework material of implant-supported prostheses on patient satisfaction and Oral Health-Related Quality of Life (OHRQoL) with mandibular All-on-4 implant distribution. The trial will investigate subject satisfaction, OHRQoL as the primary outcome, and chewing efficiency and maximum bite force as secondary outcomes for different framework materials used in implant-supported screw-retained restorations. The first null hypothesis states no significant difference in patient satisfaction and OHRQoL between the tested prostheses. Additionally, the second null hypothesis states no significant difference in chewing efficiency and maximum bite force between the tested prostheses.

Completed

Looking for future studies?

Notify Me

Key information

Age range

40 year–70 year

Sex eligibility

Male

Study type

Interventional

Phase

Not applicable

Primary location

Khloud Ezzat

Al Mansurah, 54790, Egypt

About this study

Prosthetic steps

  • For each patient, an abutment-level impression will be made, and the resultant cast will be 3D scanned for CAD/CAM construction of a PEEK superstructure with abutments.
  • A verification jig will be constructed to ensure the accuracy of the cast.
  • The final prosthesis will be virtually planned by using the Exo-Cad software.
  • The final prosthesis will be milled in Duralay polymerized resin disk, and the prosthesis resin pattern will be tried intra-orally for passive fit using a screw test.
  • For the PP, The PEEK framework will be constructed, the fit of the PEEK framework will be verified intraorally, and the final screw-retained prosthesis will be constructed of PMMA teeth and a visiolign pink composite estimating the gingival tissue.
  • For the TP, the framework will be milled from Ti blocks according to the virtual design of the final prosthesis framework. PMMA teeth then will be cemented, and the final prosthesis will be screwed.

Evaluation

  • Patient satisfaction (VAS) Patient satisfaction will be evaluated using a questionnaire based on a visual analog scale (VAS).(21) Patients will be asked to mark their answer (amount of satisfaction) on a 100-mm line (with zero referring to not satisfied at all and 100 referring to completely satisfied). The mean of the answers (length of the lines from zero to the marks in mm) for each question was subjected to statistical analysis.
  • Oral health-related quality of life (OHIP-14) The oral health impact profile (OHIP-14) questionnaire was used to measure OHRQoL. The full OHIP questionnaire consisted of 49 items covering seven main domains: functional limitation, physical pain, psychological discomfort, physical disability, psychological disability, and social disability. The OHIP-14 questionnaires were translated into Arabic by linguistic professionals who worked in collaboration with the authors to prepare the final version.
  • Evaluation of masticatory efficiency: Chewing efficiency will be evaluated using the color mixing ability test.
  • Evaluation of maximum bite force (BF): A digital BF transducer will be used to evaluate maximum BF in Newton (N).

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

The inclusion criteria include

  • healthy male patients free from systemic diseases that may affect bone health, such as uncontrolled diabetes mellitus and osteoporosis.
  • implants placed with the All-on-4 concept in the mandible.

Exclusion criteria

  • The exclusion criteria: the patients with a history of parafunctional habits (bruxism and clenching), smoking, and alcoholism

Treatment and study plan

PEEK prosthesis

Device

For the PP, The PEEK framework will be constructed, the fit of the PEEK framework will be verified intraorally, and the final screw-retained prosthesis will be constructed of PMMA teeth and a visiolign pink composite estimating the gingival tissue.

Other names: Titanium prosthesis

Titanium prosthesis

Device

For the TP, the framework will be milled from Ti blocks according to the virtual design of the final prosthesis framework. PMMA teeth then will be cemented, and the final prosthesis will be screwed.

Primary outcomes

  1. patient satisfaction

    Time frame: 3 month

    Patient satisfaction will be evaluated using a questionnaire based on a visual analog scale

  2. chewing efficiency

    Time frame: 3 month

    Chewing efficiency will be evaluated using the color mixing ability test

Secondary outcomes

  1. Oral health-related quality of life (OHRQoL)

    Time frame: 3 month

    The oral health impact profile (OHIP-14) questionnaire was used to measure OHRQoL.

  2. maximum bite force (BF)

    Time frame: 3 month

    A digital BF transducer will be used to evaluate maximum BF in Newton (N)

Sponsors and collaborators

Lead sponsor

Mansoura University

Other

Registry information

Official study title

Polyetheretherketone (PEEK) Versus Titanium Frameworks for All-on-4 Implant Full-arch Prosthesis: Within-patient Evaluation of Patient Satisfaction, Oral Health-related Quality of Life (OHRQoL), Chewing Efficiency and Maximum Bite Force

Important dates

Study start
2022
Primary completion
2023
Study completion
2023
First posted
Nov 22, 2024
Registry last updated
Jan 7, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.