This cross-over study will compare the asynchrony index between standard manual ventilator settings, optimized manual ventilator settings, and automated ventilator setting in intensive care patients ventilated in non-invasive ventilation with a high asynchrony index. The hypothesis is that both manual optimized ventilator settings and automated ventilator settings are associated with a lower patient-ventilator asynchrony index as compared to manual standard ventilator settings.
A randomized cross-over design method will be used. Patient requiring NIV with an asynchrony index over 35% will be included. An esophageal catheter with a balloon will be inserted to monitor esophageal pressure. Patients will be ventilated during 3 periods of 30 min, with 10 minutes of washout in between. Recordings of airway pressure, airway flow, and esophageal pressure will be analyzed by two investigators blinded of the trigger settings.
The primary outcome will be the asynchrony index. The secondary outcome will be the ineffective inspiratory effort index, autotrigering index, double triggering index, inspiratory trigger delay, cycling delay, total time spent in asynchrony, patient comfort, and blood gas results.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Toulon, Var, 83056, France
Non-invasive ventilation (NIV) is used in 35% of patient admitted in intensive care unit (ICU) with a failure rate of 10 to 70% depending on the indication and clinician experience. Patient-ventilator asynchrony is a frequent cause of NIV failure. Therefore, optimizing patient-ventilator synchronization is important for its comfort, tolerance, and efficacy. An optimal patient-ventilation is achieved when the mechanical breath provided by the ventilator match the patient inspiratory effort. The ratio between the number of asynchronies divided by the number of patient inspiratory effort define the asynchrony index (AI). AI over 10% is considered as severe and occurs in 30 to 43% of patients ventilated in NIV. Patient ventilator asynchronies occurs because ventilator settings of inspiratory and expiratory triggers remain constant in patient with variable respiratory drive, and unintentionnals leaks that are difficult to control in NIV. Thus using an automatic adjustment of inspiratory and expiratory triggers setting according to patient effort and unintentional leaks may decrease the number of patient-ventilator asynchronies. This cross-over study will compare the asynchrony index between standard manual ventilator settings, optimized manual ventilator settings, and automated ventilator setting in intensive care patients ventilated in non-invasive ventilation with a high asynchrony index. The hypothesis is that both manual optimized ventilator settings and automated ventilator settings are associated with a lower patient-ventilator asynchrony index as compared to manual standard ventilator settings.
A randomized cross-over design method will be used. Patient requiring NIV with an asynchrony index over 30% will be included. An esophageal catheter with a balloon will be inserted to monitor esophageal pressure. Patients will be ventilated during 3 periods of 30 min, with 10 minutes of washout in between. Recordings of airway pressure, airway flow, and esophageal pressure will be analyzed by two investigators blinded of the trigger settings.
The primary outcome will be the asynchrony index. The secondary outcome will be the ineffective inspiratory effort index, autotrigering index, double triggering index, inspiratory trigger delay, cycling delay, total time spent in asynchrony, patient comfort, and blood gas results.
The sample size was calculated from the total asynchrony index (primary outcome). Patients with an asynchrony index over 30% in using manual standard ventilator settings will be included. Considering an asynchrony index of 30 ± 15 % in manual standard ventilator settings with a clinically significant objective to reduce the asynchrony index to 15% in manual optimized ventilator settings and automated ventilator settings, a sample size of 30 patients is required with a risk at 0.05 and a power at 80%. Therefore, 35 patients are planned.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Inspiratory trigger and Expiratory trigger settings optimized by investigator
Inspiratory trigger and Expiratory trigger settings automatized
Time frame: Continuous measurement over 30min
Ratio between the total number of asynchronies divided by the number of patient inspiratory effort
Time frame: Continuous measurement over 30min
Ratio between the total number of ineffective inspiratory effort divided by the number of patient inspiratory effort
Time frame: Continuous measurement over 30min
Ratio between the total number of autotriggered breath divided by the number of patient inspiratory effort
Time frame: Continuous measurement over 30min
Ratio between the total number of double triggered breath divided by the number of patient inspiratory effort
Time frame: Continuous measurement over 30min
Time between the beginning of patient effort assessed on oesophageal pressure and beginning of mechanical breath.
Time frame: Continuous measurement over 30min
Time between the end of patient effort assessed on oesophageal pressure and the end of mechanical breath.
Time frame: Continuous measurement over 30min
Ratio of total time of ineffective inspiratory effort, inspiratory trigger delay, and cycling delay on total time of recording.
Time frame: 1 day (Single measurement)
Visual analog scale of Likert type measuring patient comfort going from 0 (very uncomfortable) to 10 (very comfortable)
Time frame: After each period at 30 min, 1 h and 1 h 30 min
PaO2
Time frame: After each period at 30 min, 1 h and 1 h 30 min
PaCO2
Time frame: After each period at 30 min, 1 h and 1 h 30 min
pH
Centre Hospitalier Intercommunal de Toulon La Seyne sur Mer
Other
Patient-ventilator Synchronisation Study in Non Invasive Ventilation for Intensive Care Unit Patients: Comparison Between Manual and Automated Ventilator Settings.
Acronym: SyncAutoVNI
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06876168
Acute Respiratory Failure, Infections
Lexington, Kentucky, United States
View Trial DetailsNCT02723565
Acute Respiratory Failure, Pathologic Processes
Toronto, Ontario, Canada
View Trial DetailsNCT07366541
Acute Respiratory Failure, Electrical Impedance Tomography (EIT)
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT05423301
Acute Respiratory Failure
Pessac, France
View Trial Details