Ankara Yıldırım Beyazıt University, Faculty of Health Sciences,Department of Physiotherapy and Rehabilitation
Ankara, Esenboğa, 06970, Turkey (Türkiye)
NCT Number: NCT04420910
The purposes of this study is to examine balance, muscle strength, and mobility in relation with non-motor symptoms (NMSs) in patients with Parkinsosn's Disease (PD).
NMSs have been shown to be the key determinant of health-related quality of life (HRQoL) and have a greater effect on HRQoL compared to motor symptoms.Despite a growing literature on NMSs, there are few data on the association between NMSs and motor phenotypes of PD, and they have usually focused only on specific domains of NMSs, such as cognition, mood/anxiety issues, or sleep disorders.
When literature is examined, there is no study which examines balance, muscle strength, and mobility in relation with NMSs in patients with PD.For all these reasons, we think that balance, muscle strength, mobility, and NMSs in patients with PD are worse than those of the healthy individuals and that there is a relationship between NMSs and motor symptoms.
Looking for future studies?
Notify Me50 year–65 year
All sexes
Observational
Ankara, Esenboğa, 06970, Turkey (Türkiye)
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
NMSs of the participants were evaluated using the Non-Motor Symptoms Scale (NMSS). The scale consists of 30 yes-no questions and is administered face to face with the therapist.
To measure balance, the Biodex Balance System (Biodex Medical Systems, Shirley, NY, USA) was used. The participants were asked to position themselves in a comfortable position on the platform, and their foot position coordinates were recorded. The participants focused on a characteristic dot on the monitor screen. Their task was to balance the body in such a way that the dot was in the center of a circle displayed on the monitor at the point of intersection of the coordinate axes. The test consisted of three 20 s trials, each separated by 10 s breaks. Measurements were conducted while their eyes were open and close, and the results were analyzed by calculating the average value of the measurements.
A Biodex® System 4 Dynamometer device was used to evaluate muscle strength. The participants' dominant extremity was determined by asking them the foot with which they most often hit the ball.The dynamometer arm of the device was placed at the lateral condyle level of the knee, and the belt at the distal end of the dynamometer was attached to the lower leg on the malleolus. Knee flexion and extension movements were evaluated in sitting position between 90ᵒ flexion and 0ᵒ extension angles. The individual was asked to perform it with the maximum strength, while the therapist motivated the individual with verbal stimulation.
The Timed Up and Go test (TUG) was used in the evaluation of functional mobility. . For this test, participants were seated on a standard armless chair and a cone was placed 3 meters away from the chair. Participants were instructed to stand up and (1) walk towards the cone, (2) turn around the cone, (3) walk back to the chair, and (4) sit back on the chair. It was stated that patients should walk without running but as fast as possible. Dual task performance was performed by adding cognitive and motor tasks into the TUG.
Time frame: one hour
Non-motor symptoms of the participants were evaluated using the Non-Motor Symptoms Scale (NMSS).Each item of the scale is scored between 0 and 30, with "yes" 1 point and "no" 0 point. According to the scoring result, "0" indicates no NMSs, "1-5" indicates mild NMSs, "6-9" indicates medium NMSs, "10-13" indicates heavy NMSs, and "≥14" indicates very heavy NMSs.
Time frame: one hour
To measure balance, the Biodex Balance System (Biodex Medical Systems, Shirley, NY, USA) was used.The test consisted of three 20 s trials, each separated by 10 s breaks. Measurements were conducted while their eyes were open and close, and the results were analyzed by calculating the average value of the measurements. As a result, overall stability and anteroposterior and mediolateral indexes were taken into account, and low values indicate high postural stability.
Time frame: one hour
A Biodex® System 4 Dynamometer device was used to evaluate muscle strength.Maximal concentric knee flexion and extension muscle strength was measured at 90 degrees/sec angular velocity with 5 repetition [19]. The flexion and extension peak torque (PT) values, peak torque/body weight (PT/BW) ratio, and hamstring/quadriceps (H/Q) ratio were recorded. Low values indicate decreased muscle strength.
Time frame: one hour
The Timed Up and Go test (TUG) was used in the evaluation of functional mobility. Dual task performance was performed by adding cognitive and motor tasks into the TUG.. As the time increases, dual task performance decreases.
Ankara Yildirim Beyazıt University
Other
Investigation of Non-motor Symptoms, Balance, Muscle Strength, and Functional Mobility in Patients With Parkinson's Disease
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07195773
Balance, Basal Ganglia Diseases
Taichung, Southern District, Taiwan
View Trial DetailsNCT05043727
Balance, Basal Ganglia Diseases
Islamabad, Fedral, Pakistan
View Trial DetailsNCT04928833
Balance, Basal Ganglia Diseases
Güneysu, Rize Province, Turkey (Türkiye)
View Trial DetailsNCT03827746
Anxiety Disorders, Balance
Istanbul, Turkey (Türkiye)
View Trial Details