University of Mississippi Medical Center
Jackson, Mississippi, 39216, United States
NCT Number: NCT03279458
Many post-operative complications arise from patients who breathe inadequately. Inadequate respiration, whether the result of surgery or the anesthesia, causes a decrease in blood oxygen saturation and an increase in carbon dioxide partial pressure. Both of these surrogate measurements of respiration may pose a challenge to measure. Some administer exogenous oxygen to all patients as they leave the operating room in order to maintain the blood oxygen saturation. This renders the oximeter a less sensitive metric of depressed respiration. In the face of decreased respiration, the carbon dioxide levels continue to increase slowly and often go undetected unless blood gases are measured. Indeed carbon dioxide blood levels are the only metric to detect inadequate ventilation using this surrogate index.
Monitoring ventilation is a serious challenge outside of critical care settings. In fact, there are no monitors available that can measure tidal volume or relative tidal volume outside of these settings.
Linshom is a novel instrument that tracks relative respiration by measuring the excursions of the temperature swings between inspiration and expiration and normalizing them to the patient's breathing. This monitor may be the first non-invasive monitor to measure relative tidal volume in non-critical care settings.
The purpose of this study is to determine whether a non-invasive, temperature-based respiratory instrument can track tidal volume (Vt) in patients.
The investigators hypothesize that the Linshom device can accurately and consistently track tidal volume as measured by closed loop mechanical ventilator.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Jackson, Mississippi, 39216, United States
Forty volunteers will be enrolled in this open label, prospective study to determine the correlation between the tidal volumes measured with the Linshom detector and those measured with the mechanical ventilator. after Institutional Review Board (IRB) approval and written informed consent from the volunteers.
The Linshom detector, which is comprised of two rapid responding medical-grade thermistors in close proximity to the mouth/nose (sensor) and a thermistor remote to the airway, will be mounted in the continuous positive airway pressure (CPAP) face mask to measure the temperature during breathing. The CPAP will be connected to a Servo-I ventilator (Maquet) with a circuit and disposable filter. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card. The temperature profiles from the sensors and the relative tidal volume will be correlated with the tidal volumes measured by the ventilator.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Volunteers will breathe through a continuous positive airway pressure (CPAP) face mask fitted wth the Linshom device. The volunteers will be instructed to breathe normal through the CPAP mask on room air. The excursions of the thermistor tracings (from valley to peak) will be recorded by the Linshom device and displayed continuously on a laptop monitor in a waveform. The tidal volume will also be measured by the ventilator and the data downloaded in a Compact Flash card.
Time frame: 5 minutes
Tidal volume measured by CPAP mask with Lishom respiratory monitoring device. Tidal volume determined from the ventilator will be compared to tidal volume measured by Linshom (calculated indirectly by temperature changes by computer algorithm)
University of Mississippi Medical Center
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04237727
Cardiovascular Diseases, Heart Arrest
Amersfoort, Utrecht, Netherlands
View Trial DetailsNCT03839537
Pulmonary Ventilation
Paris, France
View Trial DetailsNCT04667936
Hypnotics and Sedatives, Lung Diseases
Frankfurt am Main, Hesse, Germany
View Trial DetailsNCT02864017
Intubation, Pulmonary Ventilation
Angers, France
View Trial Details