NCT Number: NCT03706976

NIRS to Monitor Abdominal Tissue Oxygen Saturation in Preterm Infants

The NIRS (near infrared spectroscopy) sensor will be applied to the abdomen of the study population. To ensure good skin contact the sensor will be placed underneath the diaper. If that should not provide enough measurement stability, additional fixation will be given by employing aforementioned flexible bandage routinely employed in neonatal care. Once good skin contact is ensured, the sensor will measure aStO2 (abdominal tissue oxygen saturation) for up to seventy-two hours. The presence of this sensor will not disturb daily clinical activities or medical treatment in any way. Should good skin contact be endangered by movements, clinical interactions or such, the sensor will be removed and re-attached to the infants' abdomen as a consequence.

Completed

Looking for future studies?

Notify Me

Key information

Age range

Up to 35 week

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Universitätsspital Zürich

Zurich, Canton of Zurich, 8091, Switzerland

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Preterm infants with GA less than 35 0/7 weeks
  • Start of measurement earliest at day of life 2 for preterm infants with GA >=30 0/7 weeks and day of life 4 otherwise. The measurement will not start after day of life 5 for all GA.
  • Signed Informed consent of the legal representative(s) is received after being informed. It is sufficient, if the consent form is signed by one legal representative, which is in majority of cases either the mother or the father.
  • Clinically stable condition. The clinical stability is to be reconfirmed before the start and checked during the measurement.

Exclusion criteria

  • Injured, hypersensitive or bruised skin present on the belly,
  • Existence of clinical instability at any time during the investigation leads to exclusion, if ordered so by the physician entrusted with the investigation,
  • Any medical care equipment, e.g. patches, dressing, umbilical arterial or venous catheter, blood supply, etc., prohibiting correct placement of the sensors,
  • Dark skin pigmentation or dense hairiness on the belly absorbing too much light in the near infrared region to allow for NIRS,
  • Congenital malformations,
  • Severe metabolic disorders,
  • Early onset sepsis,
  • Inability of legal representatives to understand the purpose of the clinical trial due to language barriers such as the insufficient ability to understand the spoken or written language,
  • The treatment of newborn jaundice with light during the intended measurement time,
  • Previous enrolment into the current study,
  • Family members, employees and other dependent persons of the investigator,
  • Participation in another study with investigational drug/device within the preceding days and during the present study which may influence aStO2.

Treatment and study plan

Tissue oxygenation monitoring

Device

The NIRS sensor will be applied to the abdomen of the study population. To ensure good skin contact the sensor will be placed underneath the diaper. If that should not provide enough measurement stability, additional fixation will be given by employing aforementioned flexible bandage routinely employed in neonatal care. Once good skin contact is ensured, the sensor will measure aStO2 for up to seventy-two hours. The presence of this sensor will not disturb daily clinical activities or medical treatment in any way. Should good skin contact be endangered by movements, clinical interactions or such, the sensor will be removed and re-attached to the infants' abdomen as a consequence.

Primary outcomes

  1. Feasibility of aStO2 measurements in all patients

    Time frame: 72 hours

    aStO2 values calculated with and without considering the presence of additional absorbers besides haemoglobin.

Secondary outcomes

  1. Safety of the investigational device assessed by evaluation of adverse events

    Time frame: 72 hours

    Evaluation of AEs (Adverse Event) with regard to the investigational device. The safety related to application and use of the NIRS sensors is aimed for.

Sponsors and collaborators

Lead sponsor

Carag AG

Industry

Registry information

Official study title

NIRS to Monitor Abdominal Tissue Oxygen Saturation in Preterm Infants in an Open Mono-centric Study

Acronym: CTOM-FIH

Important dates

Study start
2019
Primary completion
2022
Study completion
2022
First posted
Oct 16, 2018
Registry last updated
Dec 20, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.