The purpose of this study is to determine the ability of a mobile clinical application to reliably and accurately track scapular motion in people with asymptomatic and symptomatic shoulders. The ability to accurately and reliably measure shoulder position clinically is an important first step in choosing the best treatment techniques to treat shoulder movement dysfunction. Therefore, the primary objectives of the study are:

1. To determine the inter- and intra-rater reliability of shoulder joint position measurements in symptomatic and asymptomatic subjects, by using a mobile application, with and without use of a handle for a smartphone 2. To determine the validity of the shoulder joint position measurements measurements as described above.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–65 year

Sex eligibility

All sexes

Study type

Observational

Primary location

University of Minnesota

Minneapolis, Minnesota, 55455, United States

About this study

Subjects will be asked to provide demographic and background information such as age, height, history of pain or injury, and descriptions of their physical activity levels. Subjects will receive a clinical screening exam by a licensed physical therapist to determine the type of movement abnormalities present, the severity of their symptoms and to screen for inclusion and exclusion criteria.

To collect scapular position measurement reliability data, subjects will stand through out data collection. Measurements of the scapula will be taken with the mobile application for the arm at rest and in two elevated position. Subjects will wear an off-the-shelf elbow brace when asked to hold their arm in the two elevated positions. These elevated positions will be maintained by having subjects maintain contact of their forearm against a guide. For intra-rater reliability, position measurements will be repeated twice for each of three planes of elevation. Additionally, for inter-rater reliability each measurement will be repeated once by two other examiners. This process will repeated twice when using the application with and without the handle.

For the validation portion of the study, a subgroup of subjects will have the same position measurements performed by a single examiner with additional motion sensors taped to the skin of their scapula and breast bone and a sensor attached to an arm brace strapped to their arm.

In total, the subject will be asked to raise and hold their arm for approximately 5 sec, 36 times during the testing within ranges of motion typically performed during daily activities.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Asymptomatic subjects: subjects without complaints or history of shoulder pain or obvious movement abnormalities.
  • Symptomatic subjects: subjects with shoulder pain who have active range of motion beyond 120° of elevation.

Exclusion criteria

  • Symptomatic and asymptomatic subjects: history of trauma including fractures, dislocations, previous shoulder surgeries within the past 6 weeks. Humeral elevation less than 120 degrees, shoulder symptomology that is judged by the examiner to be of cervical origin.
  • Asymptomatic subjects: Complaints of shoulder pain, positive results on joint tests commonly associated with shoulder impingement, presence of shoulder joint movement abnormalities as determined by a physical therapist, including thoracic scoliosis.

Treatment and study plan

Healthy Volunteers

Other

Scapula static position of subjects with and without shoulder symptoms will be recorded utilizing a mobile phone application placed on their scapula by either the examiner's hands or with a handle, held by the examiner.

Symptomatic Volunteers

Other

Scapula static position of subjects with and without shoulder symptoms will be recorded utilizing a mobile phone application placed on their scapula by either the examiner's hands or with a handle, held by the examiner.

Primary outcomes

  1. Scapular Position as assessed in degrees of joint angle by the mobile application

    Time frame: baseline

    Scapular position is measured in degrees of joint angle collected by the mobile application software collecting this information from the mobile device's measurement sensors.

Sponsors and collaborators

Lead sponsor

University of Minnesota

Other

Registry information

Official study title

1) Mobile Application Utilization for Measurement of Scapular Position 2) 3D Shoulder Motion Measurement Device (The MnMotion System)

Acronym: MnMotion

Important dates

Study start
2016
Primary completion
2017
Study completion
2019
First posted
May 16, 2016
Registry last updated
Mar 21, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.